1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
SEHF36400LSGES2B4
SEHF36400LSGES2B4
Schneider Electric - Insulated Case
SEHF36400LSGES2B4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SSF4G783U
SSF4G783U
General Electric - Insulated Case
SSF4G783U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD1G218B
SHD1G218B
General Electric - Insulated Case
SHD1G218B, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
LKD-16-MO-DO-LSG
LKD-16-MO-DO-LSG
BBC - Air
LKD-16-MO-DO-LSG, BBC, ITE, ABB, LK Series, type , 1600A integrally fused current limiting frame, manually operated/Draw-Out, 3P, 3PH, 200A, 800A or 1600A current sensor ratings available, 600V, 200kA@480V, originally supplied with Power Shield Type LSS solid-state trip device but can also be retrofitted with a modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNF4NNHDCX
MDN4083LEA0422NMNF4NNHDCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF4NNHDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
EEED460125SB2
EEED460125SB2
Cutler Hammer - Mounting Hardware
EEED460125SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 125A, ABL or BCR phase connection, 600V max, Copper, Single Branch mounting style, suitable for use with ED,EDH,EDC,JD,HJD,JDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
K3WR
K3WR
ABB - Part And Accessory
K3WR, ABB, SACE Isomax, complete 3-pole Drawout Element, rear connection bus kit, suitable for use with S3 type circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNANYNHMAX
MDN4083LEA0322NMNANYNHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNANYNHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
WLS2D316HJ
WLS2D316HJ
Siemens - Insulated Case
WLS2D316HJ, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 1600A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU748 programmer, LS - Long-Time and Short-Time trip functions and 450A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNF2ENLNWX
MDN4083LEA0522NMNF2ENLNWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNF2ENLNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
JD2B125
JD2B125
Siemens - Molded Case
JD2B125, Siemens, Sentron Series, type , 2P, 1PH, 125A, 240V, 65kA@240V, standard interrupting capacity, 40ºC, Bolt-On, complete with interchangeable trip unit and load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
B1NQ2D8
B1NQ2D8
Noark Electric - Molded Case
B1NQ2D8, Noark Electric, UL 489, type , 1PH, 2P, 120/240V, 8A, 10kA@240V, Feed-Thru box terminals, Thermal Magnetic, D trip curve, din rail mounted molded case circuit breakers
From Get Price
Limited Stock
SSD2G5W2N
SSD2G5W2N
General Electric - Insulated Case
SSD2G5W2N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT, modbus communication, relays & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF5G8R2U
SSF5G8R2U
General Electric - Insulated Case
SSF5G8R2U, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNCNYNYCSX
MDN4083LEA0822NMNCNYNYCSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNCNYNYCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
E2KM3200U66
E2KM3200U66
Westinghouse - Molded Case
E2KM3200U66, Westinghouse, Cutler Hammer, Eaton, Series C mining, type , 3P, 3PH, 200A, 1000V, 250Vdc, 14kA@1000V, standard interrupting capacity, Bolt-On, complete with 120V UVR and interchangeable trip, LI - Long-Time and Instantaneous trip functions, magnetic trip range 1000-2000A, lugs not included, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNX4YNRCWX
MDN4083LEA0622NMNX4YNRCWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX4YNRCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNX4NNAMWX
MDN4083LEA0722NMNX4NNAMWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX4NNAMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
WLL1F316FK
WLL1F316FK
Siemens - Insulated Case
WLL1F316FK, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 1600A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU748 programmer + WLLCD48 LCD display, LS - Long-Time and Short-Time trip functions and 350A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNH2NNACCX
MDN4083LEA0222NMNH2NNACCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH2NNACCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNJ4NHNDPX
MDN4083LEA0122NMNJ4NHNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJ4NHNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SEF36300LIES9B8
SEF36300LIES9B8
Schneider Electric - Insulated Case
SEF36300LIES9B8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 300A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
B325LSHPM
B325LSHPM
General Electric - Trip Units And Programmers
B325LSHPM, General Electric, MicroVersaTrip PM, type , trip units and programmers, 2500A current sensor rating, Solid State electronic, LSI - Long-Time, Short-Time and Instantaneous, high range instantaneous, trip functions, protective relays, metering & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price
Limited Stock
SEHF36200F4
SEHF36200F4
Square D - Insulated Case
SEHF36200F4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price