1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
E6V-A50-4P-5000A-BO-EO-LSI
E6V-A50-4P-5000A-BO-EO-LSI
ABB - Insulated Case
E6V-A50-4P-5000A-BO-EO-LSI, ABB, EMax, type , 4P, 3PH, 5000A frame, 5000A rating plug, 600V, 125kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SSF3G6Y3N
SSF3G6Y3N
General Electric - Insulated Case
SSF3G6Y3N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication, relays & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNX4YNCCWX
MDN4083LEA0822NMNX4YNCCWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNX4YNCCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNHNYCNDPX
MDN4083LEA0322NMNHNYCNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNHNYCNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SED36400LIGES1A4
SED36400LIGES1A4
Schneider Electric - Insulated Case
SED36400LIGES1A4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 400A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0322NMNENYNRMSX
MDN4083LEA0322NMNENYNRMSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNENYNRMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PLF34060U63BE1BC
PLF34060U63BE1BC
Square D - Molded Case
PLF34060U63BE1BC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 600A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, complete with 1A/1B alarm switch, micrologic interchangeable power 5.0P trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SSD4G6A7T
SSD4G6A7T
General Electric - Insulated Case
SSD4G6A7T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering & RELT features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG32KH400P2DN
PDG32KH400P2DN
Cutler Hammer - Molded Case
PDG32KH400P2DN, Cutler Hammer, Eaton, Power Defense, type , 600A frame, 1PH, 2P, 600V, 400A, high override, 50kA@480V, Bolt-On, no lug terminals, complete with PXR25 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions with MODBUS RTU, CAM link & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0122NMNE2YNYMPX
MDN4083LEA0122NMNE2YNYMPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNE2YNYMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
E4S-A32-4P-800A-BO-EO-LSIG
E4S-A32-4P-800A-BO-EO-LSIG
ABB - Insulated Case
E4S-A32-4P-800A-BO-EO-LSIG, ABB, EMax, type , 4P, 3PH, 3200A frame, 800A rating plug, 600V, 65kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SEHD36250LIGES3C4
SEHD36250LIGES3C4
Square D - Insulated Case
SEHD36250LIGES3C4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 250A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
TV6AB2UV2R
TV6AB2UV2R
General Electric - Under Voltage Release
TV6AB2UV2R, General Electric, MicroVersaTrip, combination accessory under voltage release UVR/ 2-600V Auxiliary switch elements, 240Vac, under voltage release, suitable for use with all MicroVersaTrip TED,THED,TFJ,TFK,THFK,TQD,THQD,TJD,TJJ,TLC4V,TJK,THJK,TJ4V,THJ4V,THJ9V,TKMA,THKM,THKMA,TK4V,THK4V frame molded case circuit breakers with MicroVersaTrip RMS-9 programmers
From Get Price
Limited Stock
PGP36120CU64BE1BC
PGP36120CU64BE1BC
Square D - Molded Case
PGP36120CU64BE1BC, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1200A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B alarm switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SEHF36400LIGT3
SEHF36400LIGT3
Square D - Insulated Case
SEHF36400LIGT3, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 150kA@480V, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 48VDC shunt trip & 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PDG32F0400E4MN
PDG32F0400E4MN
Eaton - Molded Case
PDG32F0400E4MN, Cutler Hammer, Eaton, Power Defense, type , 1PH, 2P, 600V, 400A, 25kA@480V, Bolt-On, no lug terminals, complete with PXR20 trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0222NMNA4NNRMSX
MDN4083LEA0222NMNA4NNRMSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNA4NNRMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNG2NNYCAX
MDN4083LEA0822NMNG2NNYCAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG2NNYCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNCNENYMCX
MDN4083LEA0222NMNCNENYMCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNCNENYMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
ZMVA-225-NZM10-NA
ZMVA-225-NZM10-NA
Klockner Moeller - Trip Units And Programmers
ZMVA-225-NZM10-NA, Klockner Moeller, NZM Series, Solid State trip units and programmers, 3P, 225A, 600V, LI - Long-Time and Instantaneous trip functions, suitable for use with NZM molded case switches except NZM10-400H-NA and NZM10-600H-NA
From Get Price
Limited Stock
MDN4083LEA0722NMNA4ENCNAX
MDN4083LEA0722NMNA4ENCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNA4ENCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
PGM46040U41ABD
PGM46040U41ABD
Schneider Electric - Molded Case
PGM46040U41ABD, Square D, Schneider Electric, PowerPact, type , 4P, 3PH, 400A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with 1A/1B overcurrent trip switch, micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions, line side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNX2YNCDWX
MDN4083LEA0522NMNX2YNCDWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNX2YNCDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNE2ENYNPX
MDN4083LEA0622NMNE2ENYNPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNE2ENYNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price