1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
SEHD363200LSIGES1C8
SEHD363200LSIGES1C8
Schneider Electric - Insulated Case
SEHD363200LSIGES1C8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNCNYNCDSX
MDN4083LEA0422NMNCNYNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNYNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SED361000LIGET4
SED361000LIGET4
Square D - Insulated Case
SED361000LIGET4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNR4YNLMWX
MDN4083LEA0422NMNR4YNLMWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR4YNLMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNR4NNRDWX
MDN4083LEA0722NMNR4NNRDWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR4NNRDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SHB1G2W8B
SHB1G2W8B
General Electric - Insulated Case
SHB1G2W8B, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF3G6F1U
SSF3G6F1U
General Electric - Insulated Case
SSF3G6F1U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SED363000LSIGES4D8
SED363000LSIGES4D8
Square D - Insulated Case
SED363000LSIGES4D8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SED362000LSIET5
SED362000LSIET5
Schneider Electric - Insulated Case
SED362000LSIET5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PDG32P0250E5NL
PDG32P0250E5NL
Cutler Hammer - Molded Case
PDG32P0250E5NL, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 250A, 100kA@480V, Bolt-On, load side lug terminals, complete with PXR20 trip with ARMS LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions , Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
K2000-EO-DO-LS
K2000-EO-DO-LS
ABB - Air
K2000-EO-DO-LS, ABB, K-Line, type , 2000A frame size, electrically operated/Draw-Out, 3P, 3PH, 2000A, 600V, 65kA@480V, originally supplied with OD electro-mechanical overcurrent trip device, SS, MPS or MPS-C trip device but can also be retrofitted with a modern Solid State electronic trip unit with LS - Long-Time and Short-Time trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNRNNNHNAX
MDN4083LEA0122NMNRNNNHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNRNNNHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNF2NNKNWX
MDN4083LEA0622NMNF2NNKNWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNF2NNKNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNJ4ENYNWX
MDN4083LEA0822NMNJ4ENYNWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJ4ENYNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNR2NNNDCX
MDN4083LEA0522NMNR2NNNDCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR2NNNDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, without shutters, unwired
From Get Price
Limited Stock
MPA32F40W0035
MPA32F40W0035
General Electric - Insulated Case
MPA32F40W0035, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50H trip unit, 110/130V dc/ac shunt trip and 30/48V dc undervoltage trip with delay, 3P, 3PH, 4000A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNA4NNRDPX
MDN4083LEA0522NMNA4NNRDPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA4NNRDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
PGFL3ATEM0400
PGFL3ATEM0400
General Electric - Molded Case
PGFL3ATEM0400, General Electric, GuardEon, type , 3PH, 3P, 600V, 120-400A, 150kA@480V, front connection/Feed-Thru, toggle mechanism, complete with PremEon G advanced metering interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with switchable GF, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
SEF361600LIES1C4
SEF361600LIES1C4
Square D - Insulated Case
SEF361600LIES1C4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MPA42F40N0000
MPA42F40N0000
General Electric - Insulated Case
MPA42F40N0000, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches and Mpro-27 trip unit, 4P, 3PH, 4000A, 690V, 50kA@415V, fixed/Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
23303113
23303113
ABB - Part And Accessory
23303113, ABB part and accessory
From Get Price
Limited Stock
SEHD36350S2
SEHD36350S2
Square D - Insulated Case
SEHD36350S2, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNNNEPACWX
MDN4083LEA0122NMNNNEPACWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNEPACWX, Cutler Hammer, Magnum DS, type , drawout mounted, factory installed padlock pushbutton cover, narrow plastic frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, latch check switch for external wiring, upper terminal voltage connection, operations counter, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, with shutters and pre-wired
From Get Price
Limited Stock
NPJP36060U41B
NPJP36060U41B
Square D - Molded Case
NPJP36060U41B, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 600A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price