1. Home / 
  2. breaker

SORT BY
Limited Stock
SSD1G281E
SSD1G281E
General Electric - Insulated Case
SSD1G281E, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communication, relays & ZSI features and 250A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF3G6C3P
SSF3G6C3P
General Electric - Insulated Case
SSF3G6C3P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering & modbus communication features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB3G6N8P
SSB3G6N8P
General Electric - Insulated Case
SSB3G6N8P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G399K
SSD1G399K
General Electric - Insulated Case
SSD1G399K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication, relays & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF3G6Y2M
SHF3G6Y2M
General Electric - Insulated Case
SHF3G6Y2M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB6G9C8W
SHB6G9C8W
General Electric - Insulated Case
SHB6G9C8W, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & modbus communication features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G2J8D
SSD1G2J8D
General Electric - Insulated Case
SSD1G2J8D, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & relays features and 225A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD1G269E
SHD1G269E
General Electric - Insulated Case
SHD1G269E, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication & ZSI features and 250A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB4G613T
SHB4G613T
General Electric - Insulated Case
SHB4G613T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD5G8Y31
SSD5G8Y31
General Electric - Insulated Case
SSD5G8Y31, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication, relays & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF2G5E9Q
SHF2G5E9Q
General Electric - Insulated Case
SHF2G5E9Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT & modbus communication features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB6G9A62
SHB6G9A62
General Electric - Insulated Case
SHB6G9A62, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering & RELT features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB4G7H1W
SHB4G7H1W
General Electric - Insulated Case
SHB4G7H1W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communication & relays features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD2G5R8Q
SSD2G5R8Q
General Electric - Insulated Case
SSD2G5R8Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB2G5Q2P
SHB2G5Q2P
General Electric - Insulated Case
SHB2G5Q2P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD3G6E2U
SHD3G6E2U
General Electric - Insulated Case
SHD3G6E2U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB3G6B9R
SHB3G6B9R
General Electric - Insulated Case
SHB3G6B9R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & modbus communication features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB4G7N2W
SHB4G7N2W
General Electric - Insulated Case
SHB4G7N2W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, modbus communication & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G6W1P
SSD4G6W1P
General Electric - Insulated Case
SSD4G6W1P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communcation, relays & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB6G928U
SSB6G928U
General Electric - Insulated Case
SSB6G928U, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB2G5N8U
SHB2G5N8U
General Electric - Insulated Case
SHB2G5N8U, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G216B
SSD1G216B
General Electric - Insulated Case
SSD1G216B, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB2G5Z8P
SHB2G5Z8P
General Electric - Insulated Case
SHB2G5Z8P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB4G7X91
SHB4G7X91
General Electric - Insulated Case
SHB4G7X91, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price