1. Home / 
  2. breaker

SORT BY
Limited Stock
MDN4083LEA0522NMNNNNNLNAX
MDN4083LEA0522NMNNNNNLNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNNNNNLNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNHNENKCAX
MDN4083LEA0222NMNHNENKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNHNENKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNHNENNDAX
MDN4083LEA0222NMNHNENNDAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNHNENNDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, and latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA42F32W4230
MPA42F32W4230
General Electric - Insulated Case
MPA42F32W4230, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50H trip unit, 220/250V dc/ac motor operator, 48V dc closing coil and 110/130V dc/ac shunt trip, 4P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
KG3400S35
KG3400S35
Eaton - Molded Case
KG3400S35, Eaton, Westinghouse, Cutler Hammer, Series C, type , 3P, 3PH, 400A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, magnetic pickup range 500-1000, complete with right or neutral pole mounted 380-440Vac or 220-250Vdc left side shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNC2ENHNAX
MDN4083LEA0822NMNC2ENHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2ENHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA42F32V2130
MPA42F32V2130
General Electric - Insulated Case
MPA42F32V2130, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50L trip unit, 48V dc motor operator, 24/30V dc closing coil and 110/130V dc/ac shunt trip, 4P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNNNNNYNAX
MDN4083LEA0122NMNNNNNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNNNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
FG3110S10
FG3110S10
Eaton - Molded Case
FG3110S10, Westinghouse, Cutler Hammer, Eaton, Series C, type , 3P, 3PH, 110A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 208-380Vac or 110-127Vdc, 50/60Hz rear mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNK4ENRMAX
MDN4083LEA0522NMNK4ENRMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK4ENRMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNK2ENRMAX
MDN4083LEA0622NMNK2ENRMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK2ENRMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNNNYNAMAX
MDN4083LEA0122NMNNNYNAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNYNAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNN4YNANAX
MDN4083LEA0222NMNN4YNANAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNN4YNANAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNJNENHMAX
MDN4083LEA0722NMNJNENHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJNENHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNN4ENCNSX
MDN4083LEA0522NMNN4ENCNSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNN4ENCNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNE2ENCNAX
MDN4083LEA0422NMNE2ENCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNE2ENCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNHNENCDAX
MDN4083LEA0722NMNHNENCDAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNHNENCDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SKTT3410L5L8
SKTT3410L5L8
General Electric - Molded Case
SKTT3410L5L8, General Electric, Spectra Series, type , 3P, 3PH, 1000A, 480V, 65kA@480V, standard interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm + ZSI trip functions with extended instantaneous, advanced metering + modbus + waveform capture + relay feature, Solid State electronic protection with RELT advanced function, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNJNNNYNAX
MDN4083LEA0822NMNJNNNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJNNNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNCNNNYMAX
MDN4083LEA0322NMNCNNNYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNCNNNYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA41F25N1130
MPA41F25N1130
General Electric - Insulated Case
MPA41F25N1130, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 24/30V dc motor operator, 24/30V dc closing coil and 110/130V dc/ac shunt trip, 4P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNNNEHCNAX
MDN4083LEA0122NMNNNEHCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNEHCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, factory installed padlock pushbutton cover on narrow block close PB plastic frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, castell keylock, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA42F32V4240
MPA42F32V4240
General Electric - Air
MPA42F32V4240, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50L trip unit, 220/250V dc/ac motor operator, 48V dc closing coil and 220/250V dc/ac shunt trip, 4P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNK2NNNMAX
MDN4083LEA0522NMNK2NNNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK2NNNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price