1. Home / 
  2. breaker

SORT BY
Limited Stock
MDN4083LEA0422NMNX2YNNNAX
MDN4083LEA0422NMNX2YNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNX2YNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA41F10V1310
MPA41F10V1310
General Electric - Insulated Case
MPA41F10V1310, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 24/30V dc motor operator, 110/130V dc/ac closing coil and 24/30V dc shunt trip, 4P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MPA31F12V1330
MPA31F12V1330
General Electric - Insulated Case
MPA31F12V1330, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 24/30V dc motor operator, 110/130V dc/ac closing coil, 110/130V dc/ac shunt trip, 3P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNCNENNNCX
MDN4083LEA0622NMNCNENNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNCNENNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters and unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNENNNANAX
MDN4083LEA0722NMNENNNANAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNENNNANAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNGNNNYMAX
MDN4083LEA0722NMNGNNNYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNGNNNYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA31F25N2340
MPA31F25N2340
General Electric - Insulated Case
MPA31F25N2340, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 48V dc motor operator and 110/130V dc/ac closing coil and 220/250V dc/ac shunt trip, 3P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNN4NNKNAX
MDN4083LEA0822NMNN4NNKNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNN4NNKNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNCNENRDAX
MDN4083LEA0322NMNCNENRDAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNCNENRDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNH4YNNMAX
MDN4083LEA0422NMNH4YNNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH4YNNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
RS-25A-EO-DO-LSG
RS-25A-EO-DO-LSG
Roller Smith - Air
RS-25A-EO-DO-LSG, Roller Smith, RS Series, type , 600A frame size, electrically operated/Draw-Out, 3P, 3PH, 600A max current sensor rating, 600V, 25kA@480V, originally supplied with electro-mechanical overcurrent trip device but can be retrofitted with a modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNE4NNNNAX
MDN4083LEA0522NMNE4NNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE4NNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA41F20W3320
MPA41F20W3320
General Electric - Air
MPA41F20W3320, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 110/130V dc/ac motor operator, 110/130V dc/ac closing coil and 48V dc shunt trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNANYNCNAX
MDN4083LEA0722NMNANYNCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNANYNCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNHNENCCAX
MDN4083LEA0822NMNHNENCCAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNHNENCCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
JG3175S37
JG3175S37
Cutler Hammer - Molded Case
JG3175S37, Westinghouse, Eaton, Cutler Hammer, Series C, type , 3P, 3PH, 175A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, magnetic pickup range 350-700, complete with right-pole mounted 480-600Vac, 50/60Hz right side mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MPA31F12V3450
MPA31F12V3450
General Electric - Insulated Case
MPA31F12V3450, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 110/130V dc/ac motor operator, 220/250V dc/ac closing coil, 380/400V ac shunt trip, 3P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNJ2ENCNAX
MDN4083LEA0722NMNJ2ENCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ2ENCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNKNENKCAX
MDN4083LEA0822NMNKNENKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNKNENKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNKNNNKNAX
MDN4083LEA0522NMNKNNNKNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNKNNNKNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNN2ENAMSX
MDN4083LEA0322NMNN2ENAMSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN2ENAMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
DA-75-EO-DO-LSIG
DA-75-EO-DO-LSIG
Westinghouse - Air
DA-75-EO-DO-LSIG, Westinghouse, DA Series, type , 3000A frame size, electrically operated/Draw-Out, 3P, 3PH, 3000A max current sensor rating, 600V, 75kA@480V, originally supplied with electro-mechanical oil dashpot trip device but can be retrofitted with a modern Solid State electronic trip unit with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNC2ENAMAX
MDN4083LEA0722NMNC2ENAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC2ENAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
LA-800A-MO-BO-LS
LA-800A-MO-BO-LS
Siemens-Allis - Air
LA-800A-MO-BO-LS, Siemens-Allis, LA Series, type , 800A frame size, manually operated/stationary mounted, 3P, 3PH, 80-800A current sensor ratings available, 600V, 30kA@480V, originally supplied with StaticTrip II or LimiTrip overcurrent trip devices but can also be retrofitted with a modern Solid State electronic trip unit with LS - Long-Time and Short-Time trip functions, low voltage power air circuit breakers
From Get Price