1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
SEHD36350LSGET4
SEHD36350LSGET4
Schneider Electric - Insulated Case
SEHD36350LSGET4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PJA36120CU63AE1BD
PJA36120CU63AE1BD
Square D - Molded Case
PJA36120CU63AE1BD, Schneider Electric, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 1200A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, 100% rated, complete with 1A/1B overcurrent trip switch, micrologic interchangeable power 5.0P trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SEHF36350LSIES7E8
SEHF36350LSIES7E8
Square D - Insulated Case
SEHF36350LSIES7E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNN4YNKMAX
MDN4083LEA0422NMNN4YNKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN4YNKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSB1G391K
SSB1G391K
General Electric - Insulated Case
SSB1G391K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PJP36040U31ARE10
PJP36040U31ARE10
Square D - Molded Case
PJP36040U31ARE10, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 400A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with door mounted standard black handle, micrologic interchangeable standard 3.0 trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNK4ENAMPX
MDN4083LEA0522NMNK4ENAMPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK4ENAMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
708356T05
708356T05
ABB - Frame or Mechanism Part
708356T05, ABB, BBC, ITE, K-Line, Basic Frame Assembly, suitable for K/K-Don1600/1600S, K2000/2000S, superseded by 708356-T5
From Get Price
Limited Stock
SED36300LIES7
SED36300LIES7
Square D - Insulated Case
SED36300LIES7, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 300A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
LGC340036WVH09
LGC340036WVH09
Cutler Hammer - Molded Case
LGC340036WVH09, Cutler Hammer, Series G, type , 3P, 3PH, 400A, 600V, 100kA@480V, current limiting, for Naval applications 50°C, not UL listed, Bolt-On, complete with interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs not included, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
MPA31F10V0020
MPA31F10V0020
General Electric - Insulated Case
MPA31F10V0020, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit and 48V dc shunt trip, 3P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
XT4LQ4060CFF000XXX
XT4LQ4060CFF000XXX
ABB - Molded Case
XT4LQ4060CFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 60A, 600V, 50kA@600V, Ekip DIP LIG, UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price
Limited Stock
MDN4083LEA0222NMNCNENRNAX
MDN4083LEA0222NMNCNENRNAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNCNENRNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNG2YNYCCX
MDN4083LEA0222NMNG2YNYCCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG2YNYCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
K108LIGR
K108LIGR
General Electric - Trip Units And Programmers
K108LIGR, General Electric, MicroVersaTrip Plus, replacement trip units and programmers, 800A current sensor rating, Solid State electronic, LIG - Long-Time, Instantaneous and Ground Fault trip functions, suitable for use with 1600A frame WavePro WPS,WPH,WPF,WPX low voltage power circuit breakers
From Get Price
Limited Stock
PGF36120U64AE1BC
PGF36120U64AE1BC
Square D - Molded Case
PGF36120U64AE1BC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1200A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with 1A/1B alarm switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
BGA260254
BGA260254
Schneider Electric - Molded Case
BGA260254, Schneider Electric, Square D, PowerPact, type , 1PH, 2P, 600Y/347Vac, 25A, 35kA@480V, I-Line Style Plug-In with BC phase connection, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side mechanical lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SSF4G684R
SSF4G684R
General Electric - Insulated Case
SSF4G684R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communcation, relays & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNANECNMCX
MDN4083LEA0322NMNANECNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNANECNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHD4G6N3U
SHD4G6N3U
General Electric - Insulated Case
SHD4G6N3U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communcation & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF4G6Q1U
SHF4G6Q1U
General Electric - Insulated Case
SHF4G6Q1U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communcation & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0422NMNN2ENHMPX
MDN4083LEA0422NMNN2ENHMPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN2ENHMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHB5G8N62
SHB5G8N62
General Electric - Insulated Case
SHB5G8N62, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, modbus communication & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHD361000ES2E8
SEHD361000ES2E8
Square D - Insulated Case
SEHD361000ES2E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price