1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
50H-2-1600A-EO-DO-LIG
50H-2-1600A-EO-DO-LIG
Federal Pacific - Air
50H-2-1600A-EO-DO-LIG, Federal Pacific, Federal Pioneer, H-2 Series, type , 1600A frame size, electrically operated/Draw-Out, 3P, 3PH, 1600A, 600V, 42kA@480V, available with multiple trip unit options, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, low voltage power air circuit breakers
From Get Price
Limited Stock
RLE-2000A-EO-DO-LI
RLE-2000A-EO-DO-LI
Siemens-Allis - Air
RLE-2000A-EO-DO-LI, Siemens-Allis, RL Series, type , 2000A frame size, electrically operated/Draw-Out, 3P, 3PH, 1200-2000A current sensor rating, 600V, 100kA@480V, originally supplied with StaticTrip III RMS trip device but can also be retrofitted with a modern Solid State electronic trip unit with LI - Long-Time and Instantaneous trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
PJP36100CU74BE1RE10
PJP36100CU74BE1RE10
Schneider Electric - Molded Case
PJP36100CU74BE1RE10, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1000A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with door mounted standard black handle, micrologic interchangeable harmonic 6.0H trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNC2ENNNAX
MDN4083LEA0222NMNC2ENNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNC2ENNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SEHF361400LSIES3B4
SEHF361400LSIES3B4
Square D - Insulated Case
SEHF361400LSIES3B4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNK4ENNNSX
MDN4083LEA0622NMNK4ENNNSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK4ENNNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, & load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSB1G1Z7B
SSB1G1Z7B
General Electric - Insulated Case
SSB1G1Z7B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
TPSS6610FC
TPSS6610FC
General Electric - Insulated Case
TPSS6610FC, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 1000A, Front Connected, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0322NMNKNENCNSX
MDN4083LEA0322NMNKNENCNSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNKNENCNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEHD362000LSGES8A4
SEHD362000LSGES8A4
Square D - Insulated Case
SEHD362000LSGES8A4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNX2YNCMCX
MDN4083LEA0622NMNX2YNCMCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX2YNCMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSB1G263H
SSB1G263H
General Electric - Insulated Case
SSB1G263H, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SED361200LSGES6C8
SED361200LSGES6C8
Square D - Insulated Case
SED361200LSGES6C8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNC2EHNDWX
MDN4083LEA0622NMNC2EHNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC2EHNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNR4YNCMPX
MDN4083LEA0822NMNR4YNCMPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNR4YNCMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSF1G3J8K
SSF1G3J8K
General Electric - Insulated Case
SSF1G3J8K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & relays features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MPA31F12V4200
MPA31F12V4200
General Electric - Insulated Case
MPA31F12V4200, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 220/250V dc/ac motor operator and 48V dc closing coil, 3P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
LA-4000A-EO-DO-LSG
LA-4000A-EO-DO-LSG
Siemens-Allis - Air
LA-4000A-EO-DO-LSG, Siemens-Allis, LA Series, type , 4000A frame size, electrically operated/Draw-Out, 3P, 3PH, 4000A current sensor rating, 600V, 85kA@480V, originally supplied with StaticTrip II or LimiTrip overcurrent trip devices but can also be retrofitted with a modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
PGL36040CU44BYP
PGL36040CU44BYP
Square D - Molded Case
PGL36040CU44BYP, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 400A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Feed-Thru, 100% rated, complete with fixed handle padlocking device, micrologic interchangeable ammeter 6.0A trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
LDY4B150L
LDY4B150L
Siemens - Molded Case
LDY4B150L, Siemens, VL Series, type , 4P, 3PH, 150A, 600V, 100kA@480V, very high interrupting capacity, 40°C, Feed-Thru, 100% rated, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNN4YNAMSX
MDN4083LEA0622NMNN4YNAMSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNN4YNAMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEHF364000V1
SEHF364000V1
Schneider Electric - Insulated Case
SEHF364000V1, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 4000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
E6H-A50-4P-1000A-BO-EO-LI
E6H-A50-4P-1000A-BO-EO-LI
ABB - Insulated Case
E6H-A50-4P-1000A-BO-EO-LI, ABB, EMax, type , 4P, 3PH, 5000A frame, 1000A rating plug, 600V, 85kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0822NMNGNYNHNAX
MDN4083LEA0822NMNGNYNHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNGNYNHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch, operations counter & Ronis key interlock, Solid State, low voltage power insulated case circuit breakers
From Get Price