435115
435115
General Electric - Molded Case
435115 General Electric Record Plus, type , FE160 frame, 3P, 3PH, 63A, 690V, 50kA@415V, standard interrupting capacity, Feed-Thru, complete with interchangeable LTM trip, LI - Long-Time and Instantaneous trip functions, Line Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNKNENKCSX
MDN4083LEA0822NMNKNENKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNKNENKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PDG34G0600E2XK
PDG34G0600E2XK
Cutler Hammer - Molded Case
PDG34G0600E2XK, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 600A, 35kA@480V, Bolt-On, line side lug terminals, complete with PXR20 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions with CAM link, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
SHD3G6B1T
SHD3G6B1T
General Electric - Insulated Case
SHD3G6B1T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & modbus communication features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
CSR2175NAL2
CSR2175NAL2
Cutler Hammer - Molded Case
CSR2175NAL2, Cutler Hammer, CSR Series, type , main breaker, 2P, 1PH, 175A, 240V, 25kA@240V, standard interrupting capacity, Plug-In, 2NO/2NC auxiliary contact, for use in type ECB unit enclosures, thermal magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNFNNMNMPX
MDN4083LEA0322NMNFNNMNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNFNNMNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
PDG32N0400D3ML
PDG32N0400D3ML
Cutler Hammer - Molded Case
PDG32N0400D3ML, Cutler Hammer, Eaton, Power Defense, type , 1PH, 2P, 600V, 400A, 85kA@480V, Bolt-On, load side lug terminals, complete with PXR20D trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0122HMN22ENNNAX
MDN4083LEA0122HMN22ENNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122HMN22ENNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 48Vdc shunt trip (ST), 208-250Vac second shunt trip (STA) & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SEF36800LSIT1
SEF36800LSIT1
Schneider Electric - Insulated Case
SEF36800LSIT1, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 800A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, complete with 120VAC shunt trip & 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNR4YNNMSX
MDN4083LEA0622NMNR4YNNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR4YNNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNRNENKCAX
MDN4083LEA0222NMNRNENKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNRNENKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
PGL46080U43ABD
PGL46080U43ABD
Schneider Electric - Molded Case
PGL46080U43ABD, Square D, Schneider Electric, PowerPact, type , 4P, 3PH, 800A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Feed-Thru, complete with 1A/1B overcurrent trip switch, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
In Stock
HGA36050SR
HGA36050SR
Square D - Molded Case
HGA36050SR, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 50A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 125 VDC shunt trip, molded case circuit breakers
From $1,449.00
Limited Stock
MN4L1W08
MN4L1W08
General Electric - Insulated Case
MN4L1W08, General Electric, M-PACT Plus, type , frame size 1, manually operated, with cassette and 5 N.O.-3 N.C. Auxiliary switch, 4P, 3PH, left side neutral, 800A, 690V, 65kA@415V, Draw-Out, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
SSB1G3F4I
SSB1G3F4I
General Electric - Insulated Case
SSB1G3F4I, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering & modbus communication features and 450A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
In Stock
HDA36020ABBESK
HDA36020ABBESK
Square D - Molded Case
HDA36020ABBESK, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 20A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch and overcurrent trip switch, 24 VAC shunt trip, molded case circuit breakers
From $1,315.55
Limited Stock
MDN4083LEA0122NMNA4YNYDSX
MDN4083LEA0122NMNA4YNYDSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNA4YNYDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
EE1A035
EE1A035
ITE - Molded Case
EE1A035, ITE, Siemens, EE Series, type , 1P, 1PH, 35A, 120V, 10kA@120V, standard interrupting capacity, Bolt-On, complete with I - Instantaneous protection only and load side lug terminals, standard magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers
From Get Price
Limited Stock
SHD2G424K
SHD2G424K
General Electric - Insulated Case
SHD2G424K, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT, modbus communications & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNK4NHNMCX
MDN4083LEA0822NMNK4NHNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNK4NHNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PDG34G0250P5WL
PDG34G0250P5WL
Cutler Hammer - Molded Case
PDG34G0250P5WL, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 250A, 35kA@480V, Bolt-On, load side lug terminals, complete with PXR25 trip with ARMS LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with Modbus RTU, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
PKL36120CU41BBD
PKL36120CU41BBD
Schneider Electric - Molded Case
PKL36120CU41BBD, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1200A, 600V, 50kA@480V, UL listed, high interrupting capacity, Feed-Thru, 100% rated, complete with 1A/1B overcurrent trip switch, micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SHF5G8W21
SHF5G8W21
General Electric - Insulated Case
SHF5G8W21, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT, modbus communication, relays & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHF361400LIGES3A4
SEHF361400LIGES3A4
Square D - Insulated Case
SEHF361400LIGES3A4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price