1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
SEHD361600LIGES6B8
SEHD361600LIGES6B8
Square D - Insulated Case
SEHD361600LIGES6B8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1600A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHD4G4Q7P
SHD4G4Q7P
General Electric - Insulated Case
SHD4G4Q7P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
WLL2F325NA
WLL2F325NA
Siemens - Insulated Case
WLL2F325NA, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 2500A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU725 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 800A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SEHF362500LSES2C4
SEHF362500LSES2C4
Schneider Electric - Insulated Case
SEHF362500LSES2C4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0322NMNCNENLNSX
MDN4083LEA0322NMNCNENLNSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNCNENLNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNJNYNKMPX
MDN4083LEA0222NMNJNYNKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNJNYNKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNN4ENKCWX
MDN4083LEA0722NMNN4ENKCWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4ENKCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
E3S-A08-3P-600A-DO-EO-LSI
E3S-A08-3P-600A-DO-EO-LSI
ABB - Insulated Case
E3S-A08-3P-600A-DO-EO-LSI, ABB, EMax, type , 3P, 3PH, 800A frame, 600A rating plug, 600V, 65kA@480V, Draw-Out, electrically operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0722NMNJNYNKMCX
MDN4083LEA0722NMNJNYNKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJNYNKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNG4EHNCSX
MDN4083LEA0322NMNG4EHNCSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG4EHNCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEHD36600LSES3
SEHD36600LSES3
Schneider Electric - Insulated Case
SEHD36600LSES3, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 600A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122HKH22NNNNAX
MDN4083LEA0122HKH22NNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122HKH22NNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 48Vdc shunt trip (ST), 208-250Vac second shunt trip (STA), 2A/2B auxiliary switch & mechanical trip indicator, electrically operated with factory installed 48Vdc motor operator & spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNXNYMNCCX
MDN4083LEA0422NMNXNYMNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNXNYMNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNCNENRDCX
MDN4083LEA0722NMNCNENRDCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNCNENRDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SEHF362000LSES5B4
SEHF362000LSES5B4
Square D - Insulated Case
SEHF362000LSES5B4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNA4YNRDAX
MDN4083LEA0422NMNA4YNRDAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNA4YNRDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
E3S-A25-4P-2000A-DO-EO-LSIG
E3S-A25-4P-2000A-DO-EO-LSIG
ABB - Insulated Case
E3S-A25-4P-2000A-DO-EO-LSIG, ABB, EMax, type , 4P, 3PH, 2500A frame, 2000A rating plug, 600V, 65kA@480V, Draw-Out, electrically operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0622NMNH4YNNCCX
MDN4083LEA0622NMNH4YNNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNH4YNNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
NRJF36160CU74BE1
NRJF36160CU74BE1
Schneider Electric - Molded Case
NRJF36160CU74BE1, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1600A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with micrologic interchangeable harmonic 6.0H trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
PLF34025CU43AAB
PLF34025CU43AAB
Square D - Molded Case
PLF34025CU43AAB, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 250A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, 100% rated, complete with 2A/2B auxiliary switch, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
E3S-A32-3P-1600A-DO-MO-LI
E3S-A32-3P-1600A-DO-MO-LI
ABB - Insulated Case
E3S-A32-3P-1600A-DO-MO-LI, ABB, EMax, type , 3P, 3PH, 3200A frame, 1600A rating plug, 600V, 65kA@480V, Draw-Out, manually operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0622NMNJ2YNCDCX
MDN4083LEA0622NMNJ2YNCDCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJ2YNCDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNCNYCNMSX
MDN4083LEA0522NMNCNYCNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNCNYCNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PLF34060CU41ABC
PLF34060CU41ABC
Schneider Electric - Molded Case
PLF34060CU41ABC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 600A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B alarm switch, micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price