1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0822NMNA4NNHMPX
MDN4083LEA0822NMNA4NNHMPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA4NNHMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
PLF34060CU41ARE10
PLF34060CU41ARE10
Schneider Electric - Molded Case
PLF34060CU41ARE10, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 600A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, 100% rated, complete with door mounted standard black handle, micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNN2NNNDPX
MDN4083LEA0222NMNN2NNNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNN2NNNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
BJA240805
BJA240805
Schneider Electric - Molded Case
BJA240805, Schneider Electric, Square D, PowerPact, type , 1PH, 2P, 480Y/277Vac, 80A, 65kA@480V, I-Line Style Plug-In with CA phase connection, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side mechanical lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SEF364000LSGES4B8
SEF364000LSGES4B8
Schneider Electric - Insulated Case
SEF364000LSGES4B8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 4000A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0222NMNR2NNADWX
MDN4083LEA0222NMNR2NNADWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNR2NNADWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SHB4G682R
SHB4G682R
General Electric - Insulated Case
SHB4G682R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT, modbus communcation, relays & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
E3S-A32-3P-1000A-DO-EO-LSIG
E3S-A32-3P-1000A-DO-EO-LSIG
ABB - Insulated Case
E3S-A32-3P-1000A-DO-EO-LSIG, ABB, EMax, type , 3P, 3PH, 3200A frame, 1000A rating plug, 600V, 65kA@480V, Draw-Out, electrically operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
FIL360601028
FIL360601028
Square D - Molded Case
FIL360601028, Square D, FIL Series, type , 3P, 3PH, 60A, 600V, 200kA@480V, current limiting, Feed-Thru, complete with 48Vdc shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
NP631060
NP631060
Federal Pacific - Insulated Case
NP631060, Federal Pacific, NP Series, type , 3P, 3PH, 600A, 600V, 85kA@480V, standard interrupting capacity, Bolt-On, complete with interchangeable trip unit, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, insulated case circuit breakers; these breakers are obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNF4ENLCWX
MDN4083LEA0422NMNF4ENLCWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF4ENLCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNFNNNLMSX
MDN4083LEA0522NMNFNNNLMSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNFNNNLMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & Castell key interlock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SED363200LSIGES6A4
SED363200LSIGES6A4
Square D - Insulated Case
SED363200LSIGES6A4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNHNNNKCPX
MDN4083LEA0822NMNHNNNKCPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNHNNNKCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNKNNNACPX
MDN4083LEA0522NMNKNNNACPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNKNNNACPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSB4G457P
SSB4G457P
General Electric - Insulated Case
SSB4G457P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
RKF46200U73AE1
RKF46200U73AE1
Schneider Electric - Molded Case
RKF46200U73AE1, Square D, Schneider Electric, PowerPact, type , 4P, 3PH, 2000A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with micrologic interchangeable harmonic 5.0H trip with Modbus communications, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SED362500LSES1E5
SED362500LSES1E5
Schneider Electric - Insulated Case
SED362500LSES1E5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHF4G6N6P
SHF4G6N6P
General Electric - Insulated Case
SHF4G6N6P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, modbus communcation & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB1G2K8F
SHB1G2K8F
General Electric - Insulated Case
SHB1G2K8F, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0422NMNN2EHNDCX
MDN4083LEA0422NMNN2EHNDCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN2EHNDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNF2YNCMPX
MDN4083LEA0122NMNF2YNCMPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF2YNCMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
LKE-16-EO-DO-LSG
LKE-16-EO-DO-LSG
ITE - Air
LKE-16-EO-DO-LSG, ABB, BBC, ITE, LK Series, type , 1600A frame size, electrically operated/Draw-Out, 3P, 3PH, 200A, 800A or 1600A current sensor ratings available, 600V, 65kA@480V, originally supplied with Power Shield Type LSS solid-state trip device but can also be retrofitted with a modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
SEHD363200LSIT3
SEHD363200LSIT3
Schneider Electric - Insulated Case
SEHD363200LSIT3, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, complete with 48VDC shunt trip & 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price