1. Home / 
  2. breaker

SORT BY
Limited Stock
SKTC3408L4S8
SKTC3408L4S8
General Electric - Molded Case
SKTC3408L4S8, General Electric, Spectra Series, type , 3P, 3PH, 800A, 480V, 65kA@480V, standard interrupting capacity, standard UL rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault + ZSI trip functions with extended instantaneous, advanced metering + modbus features + waveform capture + relay features, Solid State with neutral protection, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNR2ENCMAX
MDN4083LEA0522NMNR2ENCMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR2ENCMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
FG3175S05
FG3175S05
Cutler Hammer - Molded Case
FG3175S05, Cutler Hammer, Eaton, Westinghouse, Series C, type , 3P, 3PH, 175A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 48-127Vac or 48-60Vdc, 50/60Hz left side mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNC2ENYNAX
MDN4083LEA0722NMNC2ENYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC2ENYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNF4YNNMAX
MDN4083LEA0122NMNF4YNNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF4YNNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA41F12W1310
MPA41F12W1310
General Electric - Insulated Case
MPA41F12W1310, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc motor operator, 110/130V dc/ac closing coil and 24/30V dc shunt trip, 4P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNR2ENKMAX
MDN4083LEA0522NMNR2ENKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR2ENKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNK2ENYNAX
MDN4083LEA0122NMNK2ENYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK2ENYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
HFD3090VH08
HFD3090VH08
Eaton - Molded Case
HFD3090VH08, Cutler Hammer, Eaton, Westinghouse, Series C, type , 3P, 3PH, 90A, 600V, 65kA@480V, high interrupting capacity, Marine 50℃ ambient calibration, vibration testing, and no use of Al terminals, Bolt-On, LI - Long-Time and Instantaneous, complete with non-interchangeable, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, molded case circuit breakers for Marine applications, not UL listed
From Get Price
Limited Stock
MDN4083LEA0722NMNA2YNNNAX
MDN4083LEA0722NMNA2YNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNA2YNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNFNYNRNAX
MDN4083LEA0622NMNFNYNRNAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNFNYNRNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA31F20W1140
MPA31F20W1140
General Electric - Insulated Case
MPA31F20W1140, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc motor operator, 24/30V dc closing coil and 220/250V dc/ac shunt trip, 3P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNJNENKDAX
MDN4083LEA0122NMNJNENKDAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJNENKDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNHNNNKMAX
MDN4083LEA0322NMNHNNNKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNHNNNKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA03MMNMNNNENNNAX
MDN4083LEA03MMNMNNNENNNAX
Cutler Hammer - Insulated Case
MDN4083LEA03MMNMNNNENNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, Bolt-On, manually operated, complete with interchangeable Digitrip 520M, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, 120Vac trip unit power supply voltage, ground trip, load side lug terminals, Solid State electronic, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNR4ENCMAX
MDN4083LEA0522NMNR4ENCMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR4ENCMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNG2ENLNAX
MDN4083LEA0122NMNG2ENLNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNG2ENLNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, operations counter & Castell key interlock, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNA2NNNNAX
MDN4083LEA0822NMNA2NNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA2NNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA31F25N3140
MPA31F25N3140
General Electric - Insulated Case
MPA31F25N3140, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 110/130V dc/ac motor operator and 24/30V dc closing coil and 220/250V dc/ac shunt trip, 3P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNG2ENNCAX
MDN4083LEA0222NMNG2ENNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG2ENNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNG2ENCMAX
MDN4083LEA0722NMNG2ENCMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNG2ENCMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNF4ENCMAX
MDN4083LEA0422NMNF4ENCMAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF4ENCMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA31F10W3430
MPA31F10W3430
General Electric - Insulated Case
MPA31F10W3430, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 110/130V dc/ac motor operator, 220/250V dc/ac closing coil and 110/130V dc/ac shunt trip, 3P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MPA31F25W1210
MPA31F25W1210
General Electric - Insulated Case
MPA31F25W1210, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc motor operator and 48V dc closing coil and 24/30V dc shunt trip, 3P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price