1. Home / 
  2. breaker

SORT BY
Limited Stock
MPA41F10W2230
MPA41F10W2230
General Electric - Insulated Case
MPA41F10W2230, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 48V dc motor operator, 48V dc closing coil and 110/130V dc/ac shunt trip, 4P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
JG3250WS54
JG3250WS54
Cutler Hammer - Molded Case
JG3250WS54, Cutler Hammer, Eaton, Westinghouse, Series C, type , 3P, 3PH, 250A, 600V, 14kA@480V, standard interrupting capacity, Bolt-On, suitable for reverse feed applications, magnetic pickup range 350-700, complete with right-pole mounted 48-60Vac/dc, 50/60Hz rear mount shunt trip, LI - Long-Time and Instantaneous trip functions, lugs not included, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
SED363200LIGES3F8
SED363200LIGES3F8
Square D - Insulated Case
SED363200LIGES3F8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNK2EHNMCX
MDN4083LEA0522NMNK2EHNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK2EHNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNRNYNLCWX
MDN4083LEA0122NMNRNYNLCWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNRNYNLCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNF2YNAMCX
MDN4083LEA0822NMNF2YNAMCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF2YNAMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
WLH1D312MF
WLH1D312MF
Siemens - Insulated Case
WLH1D312MF, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 1200A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU745 programmer + WLLCD48 LCD display + WLGFA48 ground fault module, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 700A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
M4S400T2D
M4S400T2D
Noark Electric - Molded Case
M4S400T2D, Noark Electric, Ex9 Series, type , 1PH, 2P, 600V, 400A, 65kA@240V, complete with LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNR4YNCDSX
MDN4083LEA0122NMNR4YNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNR4YNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEHD36250LIGES3D8
SEHD36250LIGES3D8
Square D - Insulated Case
SEHD36250LIGES3D8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 250A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
In Stock
HJA36125AEBKSLYP
HJA36125AEBKSLYP
Square D - Molded Case
HJA36125AEBKSLYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 125A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 48 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,655.87
Limited Stock
SHF3G6Y3U
SHF3G6Y3U
General Electric - Insulated Case
SHF3G6Y3U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication, relays & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
140G-H2C4-C25
140G-H2C4-C25
Allen-Bradley - Molded Case
140G-H2C4-C25, Allen-Bradley, Bulletin 140G, type , 4P, 3PH, 25A, 600V, 25kA@480V, standard interrupting capacity, Bolt-On, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNG2NNRNSX
MDN4083LEA0222NMNG2NNRNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG2NNRNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
A1B230VH
A1B230VH
Square D - Molded Case
A1B230VH, Square D, A1B Series, type , 2P, 1PH, 30A, rated for 240VAC & 48VDC, 22kA@240V, standard interrupting capacity, 40°C, Bolt-On, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; these product are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNG2EHKDSX
MDN4083LEA0422NMNG2EHKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG2EHKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNJ2NNRNAX
MDN4083LEA0622NMNJ2NNRNAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJ2NNRNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
435906
435906
General Electric - Molded Case
435906 General Electric Record Plus, type , FE250 frame, FEH436TG200KF, 4P, 3PH, 200A, 690V, 80kA@415V, Feed-Thru, complete with 3-pole interchangeable GTM trip, LI - Long-Time and Instantaneous trip functions, generator Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SEHF361000LSGES4E4
SEHF361000LSGES4E4
Schneider Electric - Insulated Case
SEHF361000LSGES4E4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHD362500LSIGES9F4
SEHD362500LSIGES9F4
Schneider Electric - Insulated Case
SEHD362500LSIGES9F4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2500A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0222NMNH2YNRMWX
MDN4083LEA0222NMNH2YNRMWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH2YNRMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNH2YNRCSX
MDN4083LEA0722NMNH2YNRCSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH2YNRCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNJ4YNKMCX
MDN4083LEA0622NMNJ4YNKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJ4YNKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNN2YNKNSX
MDN4083LEA0222NMNN2YNKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNN2YNKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price