SEHD361600LIES9C8
SEHD361600LIES9C8
Square D - Insulated Case
SEHD361600LIES9C8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1600A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SED361200LIGES2B8
SED361200LIGES2B8
Square D - Insulated Case
SED361200LIGES2B8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNXNENYCWX
MDN4083LEA0122NMNXNENYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNXNENYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNH2YNACAX
MDN4083LEA0122NMNH2YNACAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNH2YNACAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
In Stock
HDA36090ABBCUK
HDA36090ABBCUK
Square D - Molded Case
HDA36090ABBCUK, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 90A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch, 24 VAC under voltage release (UVR), molded case circuit breakers
From $1,743.00
Limited Stock
SEF362500LIGE8
SEF362500LIGE8
Square D - Insulated Case
SEF362500LIGE8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0722NMNH2YNHDSX
MDN4083LEA0722NMNH2YNHDSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH2YNHDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSB1G2A1K
SSB1G2A1K
General Electric - Insulated Case
SSB1G2A1K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering & RELT features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG53N0800E3ZN
PDG53N0800E3ZN
Eaton - Molded Case
PDG53N0800E3ZN, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 800A, 85kA@480V, Bolt-On, no terminals, complete with PXR20 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with modbus & ZSI option, Solid State electronic, molded case circuit breakers; globally rated
From Get Price
Limited Stock
PJA36060U43AE1AC
PJA36060U43AE1AC
Schneider Electric - Molded Case
PJA36060U43AE1AC, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 600A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 3A/3B auxiliary switch, modbus communications, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SEHF363200ES5C8
SEHF363200ES5C8
Schneider Electric - Insulated Case
SEHF363200ES5C8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
NG3700S24
NG3700S24
Eaton - Molded Case
NG3700S24, Cutler Hammer, Eaton, Westinghouse, Series C, type , 3P, 3PH, 700A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, magnetic pickup range 500-2500, complete with left-pole mounted 48-60Vdc, 50/60Hz terminal block left side mount shunt trip, I - Instantaneous trip functions and line & load side lug terminals, Solid State electronic, engine generator molded case circuit breakers
From Get Price
Limited Stock
LV432809X53E630
LV432809X53E630
Schneider Electric - Molded Case
LV432809X53E630 Schneider Electric Compact NSX, type , 4P, 3PH, 630A, 690V, 70kA@415V, Bolt-On, complete with NSX630H frame and 3 pole, 630A Micrologic 5.3E trip unit with LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SEHD361400LSIGS1
SEHD361400LSIGS1
Schneider Electric - Insulated Case
SEHD361400LSIGS1, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 120VAC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNE4ENLMSX
MDN4083LEA0822NMNE4ENLMSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNE4ENLMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNC4YNLCCX
MDN4083LEA0822NMNC4YNLCCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC4YNLCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNK2NHNNAX
MDN4083LEA0322NMNK2NHNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK2NHNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNR2YNYDCX
MDN4083LEA0122NMNR2YNYDCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNR2YNYDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
NPJA36060
NPJA36060
Square D - Molded Case
NPJA36060, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 600A, 600V, 65kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with basic non-interchangeable ET 1.0I trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
In Stock
HGA36020UKYP
HGA36020UKYP
Square D - Molded Case
HGA36020UKYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 20A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 24 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,570.43
Limited Stock
MDN4083LEA0322NMNK4YNNNPX
MDN4083LEA0322NMNK4YNNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK4YNNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSF5G8291
SSF5G8291
General Electric - Insulated Case
SSF5G8291, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT, modbus communication & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
EEHKD260250SB2
EEHKD260250SB2
Cutler Hammer - Mounting Hardware
EEHKD260250SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 250A, AC phase connection, 600V max, Copper, Single Branch mounting style, suitable for use with KD,HKD,KDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
SSB2G569Q
SSB2G569Q
General Electric - Insulated Case
SSB2G569Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price