FG3060S07
FG3060S07
Westinghouse - Molded Case
FG3060S07, Eaton, Westinghouse, Cutler Hammer, Series C, type , 3P, 3PH, 60A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 48-127Vac or 48-60Vdc, 50/60Hz right side mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
RL-800A-MO-BO-LSG
RL-800A-MO-BO-LSG
Siemens-Allis - Air
RL-800A-MO-BO-LSG, Siemens-Allis, RL Series, type , 800A frame size, manually operated/stationary mounted, 3P, 3PH, 150-800A current sensor rating, 600V, 30kA@480V, originally supplied with StaticTrip III RMS trip device but can also be retrofitted with a modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
FP50-1600A-MO-DO-LSG
FP50-1600A-MO-DO-LSG
Federal Pacific - Air
FP50-1600A-MO-DO-LSG, Federal Pacific, FP Series, type , 1600A frame size, manually operated/Draw-Out, 3P, 3PH, 1600A, 600V, 50kA@480V, originally supplied with electro-mechanical TD-1 or TD-2 overcurrent trip device, but can also be retrofitted with modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122RMNH2ENNNAX
MDN4083LEA0122RMNH2ENNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122RMNH2ENNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 208-250Vac shunt trip (ST), 48Vdc UVR & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SKLL3612L5Z2
SKLL3612L5Z2
General Electric - Molded Case
SKLL3612L5Z2 General Electric Spectra Series, type , 3P, 3PH, 1200A, 600V, 65kA@480V, extra high interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIA, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm and ZSI, zone selective interlocking trip functions and basic metering and modbus communication features, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
LA-4000A-EO-DO-LIG
LA-4000A-EO-DO-LIG
Siemens-Allis - Air
LA-4000A-EO-DO-LIG, Siemens-Allis, LA Series, type , 4000A frame size, electrically operated/Draw-Out, 3P, 3PH, 4000A current sensor rating, 600V, 85kA@480V, originally supplied with StaticTrip II or LimiTrip overcurrent trip devices but can also be retrofitted with a modern Solid State electronic trip unit with LIG - Long-Time, Instantaneous and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNKNEMNMAX
MDN4083LEA0422NMNKNEMNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNKNEMNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
FG3060S14
FG3060S14
Westinghouse - Molded Case
FG3060S14, Cutler Hammer, Eaton, Westinghouse, Series C, type , 3P, 3PH, 60A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 415-600Vac or 220-250Vdc, 50/60Hz rear mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNH2ENNDAX
MDN4083LEA0822NMNH2ENNDAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH2ENNDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
FG3040S01
FG3040S01
Cutler Hammer - Molded Case
FG3040S01, Eaton, Cutler Hammer, Westinghouse, Series C, type , 3P, 3PH, 40A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 12-24Vac/dc, 50/60Hz left side mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
LA-3000A-EO-DO-LI
LA-3000A-EO-DO-LI
Siemens-Allis - Air
LA-3000A-EO-DO-LI, Siemens-Allis, LA Series, type , 3000A frame size, electrically operated/Draw-Out, 3P, 3PH, 2000A or 3200A current sensor rating, 600V, 65kA@480V, originally supplied with StaticTrip II or LimiTrip overcurrent trip devices but can also be retrofitted with a modern Solid State electronic trip unit with LI - Long-Time and Instantaneous trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
RL-1600A-MO-BO-LSG
RL-1600A-MO-BO-LSG
Siemens-Allis - Air
RL-1600A-MO-BO-LSG, Siemens-Allis, RL Series, type , 1600A frame size, manually operated/stationary mounted, 3P, 3PH, 1200-1600A current sensor rating, 600V, 65kA@480V, originally supplied with StaticTrip III RMS trip device but can also be retrofitted with a modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNRNNNCMAX
MDN4083LEA0722NMNRNNNCMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNRNNNCMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
RLE-4000A-MO-BO-LS
RLE-4000A-MO-BO-LS
Siemens-Allis - Air
RLE-4000A-MO-BO-LS, Siemens-Allis, RL Series, type , 4000A frame size, manually operated/stationary mounted, 3P, 3PH, 1600-4000A current sensor rating, 600V, 100kA@480V, originally supplied with StaticTrip III RMS trip device but can also be retrofitted with a modern Solid State electronic trip unit with LS - Long-Time and Short-Time trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
FG3030S11
FG3030S11
Cutler Hammer - Molded Case
FG3030S11, Westinghouse, Cutler Hammer, Eaton, Series C, type , 3P, 3PH, 30A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 208-380Vac or 110-127Vdc, 50/60Hz right side mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNR2ENKNAX
MDN4083LEA0822NMNR2ENKNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNR2ENKNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNK4ENKMAX
MDN4083LEA0222NMNK4ENKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK4ENKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNNNENNCAX
MDN4083LEA0122NMNNNENNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNENNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, latch check switch for external wiring, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, upper terminal voltage connection, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNXNNNAMAX
MDN4083LEA0622NMNXNNNAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNXNNNAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA41F20V1330
MPA41F20V1330
General Electric - Insulated Case
MPA41F20V1330, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 24/30V dc motor operator, 110/130V dc/ac closing coil and 110/130V dc/ac shunt trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
KG3350WS30
KG3350WS30
Cutler Hammer - Molded Case
KG3350WS30, Westinghouse, Cutler Hammer, Eaton, Series C, type , 3P, 3PH, 350A, 600V, 14kA@480V, standard interrupting capacity, Bolt-On, suitable for reverse feed applications, magnetic pickup range 500-1000, complete with right-pole mounted 110-240Vac or 110-125Vdc, 50/60Hz rear mount shunt trip, LI - Long-Time and Instantaneous trip functions, lugs not included, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNR4ENAMAX
MDN4083LEA0322NMNR4ENAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNR4ENAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SKHH3610L4T6
SKHH3610L4T6
General Electric - Molded Case
SKHH3610L4T6 General Electric Spectra Series, type , 3P, 3PH, 1000A, 600V, 50kA@480V, extra high interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIG, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault and ZSI, zone selective interlocking trip functions and advanced metering, modbus & waveform capture communication features, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNHNNNANAX
MDN4083LEA0722NMNHNNNANAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNHNNNANAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price