1. Home / 
  2. breaker

SORT BY
Limited Stock
MDN4083LEA0722NMNN2ENNMCX
MDN4083LEA0722NMNN2ENNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN2ENNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions & load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNFNNNLNAX
MDN4083LEA0722NMNFNNNLNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNFNNNLNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & Castell key interlock, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNN2ENCMCX
MDN4083LEA0422NMNN2ENCMCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN2ENCMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNJNNNYMAX
MDN4083LEA0822NMNJNNNYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJNNNYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
FG3100S03
FG3100S03
Westinghouse - Molded Case
FG3100S03, Cutler Hammer, Eaton, Westinghouse, Series C, type , 3P, 3PH, 100A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 12-24Vac/dc, 50/60Hz right side mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNE4ENKNAX
MDN4083LEA0122NMNE4ENKNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNE4ENKNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122RMNJNNNNNAX
MDN4083LEA0122RMNJNNNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122RMNJNNNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 208-250Vac shunt trip (ST), 480Vac UVR & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNN4ENYNAX
MDN4083LEA0422NMNN4ENYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN4ENYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
FP50-800A-EO-BO-LSG
FP50-800A-EO-BO-LSG
Federal Pacific - Air
FP50-800A-EO-BO-LSG, Federal Pacific, FP Series, type , 800A frame size, electrically operated/Bolt-On, 3P, 3PH, 800A, 600V, 50kA@480V, originally supplied with electro-mechanical TD-1 or TD-2 overcurrent trip device, but can also be retrofitted with modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNN2ENYNAX
MDN4083LEA0322NMNN2ENYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN2ENYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
FG3025S14
FG3025S14
Westinghouse - Molded Case
FG3025S14, Cutler Hammer, Eaton, Westinghouse, Series C, type , 3P, 3PH, 25A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 415-600Vac or 220-250Vdc, 50/60Hz rear mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
SKSS3410L5R8
SKSS3410L5R8
General Electric - Molded Case
SKSS3410L5R8, General Electric, Spectra Series, type , 3P, 3PH, 1000A, 480V, 100kA@480V, standard interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions with extended instantaneous, advanced metering + modbus + waveform capture + relay feature, Solid State electronic protection with RELT advanced function, molded case circuit breakers
From Get Price
Limited Stock
MPA42F32V3230
MPA42F32V3230
General Electric - Air
MPA42F32V3230, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50L trip unit, 110/130V dc/ac motor operator, 48V dc closing coil and 110/130V dc/ac shunt trip, 4P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNR2ENRMAX
MDN4083LEA0722NMNR2ENRMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR2ENRMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA32F40W3210
MPA32F40W3210
General Electric - Insulated Case
MPA32F40W3210, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50H trip unit, 110/130V dc/ac motor operator, 48V dc closing coil and 24/30V dc shunt trip, 3P, 3PH, 4000A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNKNYNLNAX
MDN4083LEA0222NMNKNYNLNAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNKNYNLNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch, & Castell key interlock, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNG4ENRMAX
MDN4083LEA0322NMNG4ENRMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG4ENRMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
AKR-10B-30SA
AKR-10B-30SA
General Electric - Air
AKR-10B-30SA, General Electric, AKR Series, type , 800A frame, 3PH, 3P, 635Vac, 150-800A sensor rating available, 30kA@508V, Draw-Out with substructure, available either mechanically operated or electrically operated, with MVT+ or MVT PM programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, optional functions available, with new arc chute construction, Solid State electronic, low voltage air circuit breakers
From Get Price
Limited Stock
MPA41F20V2440
MPA41F20V2440
General Electric - Insulated Case
MPA41F20V2440, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 48V dc motor operator, 220/250V dc/ac closing coil and 220/250V dc/ac shunt trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MPA41F20V1140
MPA41F20V1140
General Electric - Insulated Case
MPA41F20V1140, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 24/30V dc motor operator, 24/30V dc closing coil and 220/250V dc/ac shunt trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNNNYNRNAX
MDN4083LEA0422NMNNNYNRNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNNNYNRNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA31F25V4450
MPA31F25V4450
General Electric - Air
MPA31F25V4450, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 220/250V dc/ac motor operator and 220/250V dc/ac closing coil and 380/400V ac shunt trip, 3P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
KG3300WS32
KG3300WS32
Westinghouse - Molded Case
KG3300WS32, Cutler Hammer, Eaton, Westinghouse, Series C, type , 3P, 3PH, 300A, 600V, 14kA@480V, standard interrupting capacity, Bolt-On, suitable for reverse feed applications, magnetic pickup range 500-1000, complete with right-pole mounted 110-240Vac or 110-125Vdc, 50/60Hz terminal block right side mount shunt trip, LI - Long-Time and Instantaneous trip functions, lugs not included, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
SKLL3608L4R8
SKLL3608L4R8
General Electric - Molded Case
SKLL3608L4R8 General Electric Spectra Series, type , 3P, 3PH, 800A, 600V, 65kA@480V, extra high interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIG, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault and RELT, reduced energy let-through trip functions and advanced metering, modbus, waveform capture & protective relays communication features, Solid State electronic, molded case circuit breakers
From Get Price