1. Home / 
  2. breaker

SORT BY
Limited Stock
MDN4083LEA0322NMNK2NNNMAX
MDN4083LEA0322NMNK2NNNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK2NNNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNX2ENKMAX
MDN4083LEA0122NMNX2ENKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNX2ENKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
FG3200S04
FG3200S04
Eaton - Molded Case
FG3200S04, Westinghouse, Cutler Hammer, Eaton, Series C, type , 3P, 3PH, 200A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 12-24Vac/dc, 50/60Hz terminal block left side mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNC2ENCNAX
MDN4083LEA0322NMNC2ENCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNC2ENCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNXNENKCAX
MDN4083LEA0722NMNXNENKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNXNENKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNR2ENAMAX
MDN4083LEA0422NMNR2ENAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR2ENAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNHNNNYNAX
MDN4083LEA0122NMNHNNNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNHNNNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNCNNNANAX
MDN4083LEA0122NMNCNNNANAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNCNNNANAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNJNNNLNAX
MDN4083LEA0422NMNJNNNLNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNJNNNLNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & Castell key interlock, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
HFD3080VH08
HFD3080VH08
Eaton - Molded Case
HFD3080VH08, Westinghouse, Eaton, Cutler Hammer, Series C, type , 3P, 3PH, 80A, 600V, 65kA@480V, high interrupting capacity, Marine 50℃ ambient calibration, vibration testing, and no use of Al terminals, Bolt-On, LI - Long-Time and Instantaneous, complete with non-interchangeable, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, molded case circuit breakers for Marine applications, not UL listed
From Get Price
Limited Stock
MDN4083LEA0522NMNH4YNNMAX
MDN4083LEA0522NMNH4YNNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNH4YNNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNA4YNNMAX
MDN4083LEA0622NMNA4YNNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNA4YNNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNG2ENNDAX
MDN4083LEA0722NMNG2ENNDAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNG2ENNDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNHNNNLNAX
MDN4083LEA0222NMNHNNNLNAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNHNNNLNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA41F12W4310
MPA41F12W4310
General Electric - Insulated Case
MPA41F12W4310, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 220/250V dc/ac motor operator, 110/130V dc/ac closing coil, 24/30V dc shunt trip, 4P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MPA31F20V1330
MPA31F20V1330
General Electric - Insulated Case
MPA31F20V1330, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 24/30V dc motor operator, 110/130V dc/ac closing coil and 110/130V dc/ac shunt trip, 3P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNHNENCDAX
MDN4083LEA0222NMNHNENCDAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNHNENCDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA41F12W2110
MPA41F12W2110
General Electric - Insulated Case
MPA41F12W2110, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 48V dc motor operator, 24/30V dc closing coil and 24/30V dc shunt trip, 4P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNK4ENLNAX
MDN4083LEA0122NMNK4ENLNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK4ENLNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNK2ENAMAX
MDN4083LEA0722NMNK2ENAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNK2ENAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNKNENKDAX
MDN4083LEA0122NMNKNENKDAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNKNENKDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA32F32W1330
MPA32F32W1330
General Electric - Insulated Case
MPA32F32W1330, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc motor operator, 110/130V dc/ac closing coil, 110/130V dc/ac shunt trip, 3P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
KDON-1600-MO-BO-LI
KDON-1600-MO-BO-LI
ABB - Air
KDON-1600-MO-BO-LI, ABB, K-Line, type , 1600A fused frame size, manually operated/Bolt-On, 3P, 3PH, 1600A, 600V, 200kA@480V, originally supplied with OD electro-mechanical overcurrent trip device, SS, MPS or MPS-C trip device but can also be retrofitted with a modern Solid State electronic trip unit with LI - Long-Time and Instantaneous trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNFNNNCNAX
MDN4083LEA0822NMNFNNNCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNFNNNCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price