1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0822NMNJNENRDSX
MDN4083LEA0822NMNJNENRDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJNENRDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHB2G596U
SHB2G596U
General Electric - Insulated Case
SHB2G596U, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
FNT406024RSG5CT
FNT406024RSG5CT
General Electric - Part And Accessory
FNT406024RSG5CT, General Electric, EntellEon, type , panelboard fronts, top, 40 enclosure width
From Get Price
Limited Stock
MDN4083LEA0622NMNE2EHNMSX
MDN4083LEA0622NMNE2EHNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNE2EHNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEF36400ES5A4
SEF36400ES5A4
Square D - Insulated Case
SEF36400ES5A4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
EGE4090AFGVH08
EGE4090AFGVH08
Cutler Hammer - Molded Case
EGE4090AFGVH08, Cutler Hammer, Series G, type , 4P, 3PH, 90A, 600V, 25kA@480V, standard interrupting capacity, for Marine applications 50°C, not UL listed, Feed-Thru, complete with interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SSF4G6N6N
SSF4G6N6N
General Electric - Insulated Case
SSF4G6N6N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, modbus communcation & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNG4YNNCAX
MDN4083LEA0722NMNG4YNNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNG4YNNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122ALCF2NNNNAX
MDN4083LEA0122ALCF2NNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122ALCF2NNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 110-127Vac shunt trip (ST), 220-250Vdc UVR, 2A/2B auxiliary switch & mechanical trip indicator, electrically operated with factory installed 24Vdc motor operator & spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SEF363200LSIET3
SEF363200LSIET3
Schneider Electric - Insulated Case
SEF363200LSIET3, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNN4YNAMPX
MDN4083LEA0522NMNN4YNAMPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNN4YNAMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SEF36800LSIE4
SEF36800LSIE4
Square D - Insulated Case
SEF36800LSIE4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 800A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, complete with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHD36200LSGES9A8
SEHD36200LSGES9A8
Square D - Insulated Case
SEHD36200LSGES9A8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 200A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
450D010G18
450D010G18
Westinghouse - Mounting Hardware
450D010G18, Westinghouse, TRI-PAC, mounting hardware, load side plug-in adapter kit, rated for 600A, 600V max, Copper, Single Branch mounting style, suitable for use with 2-pole Tri-Pac LA circuit breaker frames, complete with all associated hardware, screws and cover plates
From Get Price
Limited Stock
SEHD36300LIGES6B8
SEHD36300LIGES6B8
Square D - Insulated Case
SEHD36300LIGES6B8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 300A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNN2ENCCPX
MDN4083LEA0422NMNN2ENCCPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN2ENCCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNXNENCNSX
MDN4083LEA0822NMNXNENCNSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNXNENCNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHB1G323F
SHB1G323F
General Electric - Insulated Case
SHB1G323F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communication & ZSI features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
FAL360701427
FAL360701427
Square D - Molded Case
FAL360701427, Square D, FAL Series, type , 3P, 3PH, 70A, 600V, 18kA@480V, standard interrupting capacity, Feed-Thru, complete with 277/480Vac shunt trip and 2A/2B aux switch, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
SED362500LIES3E4
SED362500LIES3E4
Square D - Insulated Case
SED362500LIES3E4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PDG32M0125E3RN
PDG32M0125E3RN
Eaton - Molded Case
PDG32M0125E3RN, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 125A, 65kA@480V, Bolt-On, no lug terminals, complete with PXR20 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0422NMNA2NNHNWX
MDN4083LEA0422NMNA2NNHNWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNA2NNHNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
3VL8716-1SB36-0AA0
3VL8716-1SB36-0AA0
Siemens - Molded Case
3VL8716-1SB36-0AA0, Siemens, SENTRON 3VL, type , 1P, 1PH, 1600A, 690V, 55kA@415V, Bolt-On/fixed mount with lug terminal, complete with LI - Long-Time and Instantaneous trip functions, ETU10 Solid State electronic trip, molded case circuit breakers
From Get Price
Limited Stock
LJP36400RU53X
LJP36400RU53X
Square D - Molded Case
LJP36400RU53X, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 400A, 600V, 65kA@480V, UL listed, current limiting, 100% rated, Bolt-On, complete with interchangeable micrologic energy 5.3E trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price