1. Home / 
  2. 15 amp breaker

SORT BY
In Stock
HDA36035AABKUHYP
HDA36035AABKUHYP
Square D - Molded Case
HDA36035AABKUHYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 35A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B aux switch, alarm switch and overcurrent trip switch, low-level, 380/480 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,687.77
In Stock
HDL26020ABBEUDYP
HDL26020ABBEUDYP
Square D - Molded Case
HDL26020ABBEUDYP, Square D, PowerPact, type , 2P, 1PH, 20A, 600V, 18kA@480V, standard interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch and overcurrent trip switch, 208/277 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $955.50
Limited Stock
MDN4083LEA0522NMNX2NHNNSX
MDN4083LEA0522NMNX2NHNNSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNX2NHNNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNC2NNACSX
MDN4083LEA0822NMNC2NNACSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2NNACSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNGNYNNDPX
MDN4083LEA0222NMNGNYNNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNGNYNNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHF1G326N
SHF1G326N
General Electric - Insulated Case
SHF1G326N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG42M0700VFAK
PDG42M0700VFAK
Cutler Hammer - Molded Case
PDG42M0700VFAK, Cutler Hammer, Eaton, Power Defense, type , 50º C non-UL listed, 1PH, 2P, 600V, 700A, 65kA@480V, Bolt-On, line side lug terminals, complete with LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; globally rated non-UL listed
From Get Price
Limited Stock
609907-T204
609907-T204
ABB - Trip Units And Programmers
609907-T204, ABB, Power Shield trip units and programmers, type , 300A - 800A, Solid State with LSG - Long-Time, Short-Time and Ground Fault functions; suitable for use with K-800S,K-DON800S air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNC4ECNNCX
MDN4083LEA0322NMNC4ECNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNC4ECNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNRNNNYCSX
MDN4083LEA0422NMNRNNNYCSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNRNNNYCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNH2ENAMPX
MDN4083LEA0222NMNH2ENAMPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH2ENAMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
PLM34080CU74AE1BD
PLM34080CU74AE1BD
Square D - Molded Case
PLM34080CU74AE1BD, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 800A, 480V, 100kA@480V, UL listed, extra high interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B overcurrent trip switch, micrologic interchangeable harmonic 6.0H trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
In Stock
HGA36035ABBKUAYP
HGA36035ABBKUAYP
Square D - Molded Case
HGA36035ABBKUAYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 35A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch and overcurrent trip switch, low-level, 120 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,840.45
Limited Stock
SSD3G6E6T
SSD3G6E6T
General Electric - Insulated Case
SSD3G6E6T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, RELT & modbus communication features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
BGF46050
BGF46050
Square D - Molded Case
BGF46050, Square D, Schneider Electric, PowerPact, type , 3PH, 4P, 600Y/347Vac, 50A, 35kA@480V, Bolt-On with terminal nut connectors, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNC4YNKCSX
MDN4083LEA0222NMNC4YNKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNC4YNKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
NQOD484L600
NQOD484L600
Square D - Panel Board
NQOD484L600, Square D, NQOD, Main Lug Only, lighting panel board, 240V, 3-phase, 4-wire, 600A, interior only, Aluminum bus, accepts max 84 single pole QO/QOB branch circuit breakers
From Get Price
Limited Stock
JE3250U33X
JE3250U33X
Square D - Trip Units And Programmers
JE3250U33X, Square D, PowerPact, type , interchangeable 3.2S trip unit with LSI, LSI - Long-Time, Short-Time and Instantaneous trip functions, rated for 250A, suitable for J Frame 250A- JDL,JGL,JJL,JLL molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price
Limited Stock
MPA41F2001050
MPA41F2001050
General Electric - Insulated Case
MPA41F2001050, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 24/30V dc motor operator and 380/400V ac shunt trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNXNNNYNSX
MDN4083LEA0222NMNXNNNYNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNXNNNYNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNG2ENNMAX
MDN4083LEA0822NMNG2ENNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG2ENNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions,& load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
31T-115-R
31T-115-R
Eaton - Bell Alarm
31T-115-R, Eaton bell alarm
From Get Price
Limited Stock
SEHD363200LSIGES7F4
SEHD363200LSIGES7F4
Schneider Electric - Insulated Case
SEHD363200LSIGES7F4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0322NMNGNENLDAX
MDN4083LEA0322NMNGNENLDAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNGNENLDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Castell key interlock & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price