1. Home / 
  2. square d breaker

SORT BY
Limited Stock
SSF5G827W
SSF5G827W
General Electric - Insulated Case
SSF5G827W, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communication & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD1G1H9A
SHD1G1H9A
General Electric - Insulated Case
SHD1G1H9A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication and relays features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB4G6Q1N
SHB4G6Q1N
General Electric - Insulated Case
SHB4G6Q1N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communcation & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SPB50-3P-600A-MO-DO-LS
SPB50-3P-600A-MO-DO-LS
Cutler Hammer - Insulated Case
SPB50-3P-600A-MO-DO-LS, Cutler Hammer, Systems Pow-R, type , 800A frame size, 3P, 3PH, 600A, 600V, 50kA@480V, standard interrupting capacity, Draw-Out, manually operated, available with Pow-R Trip, Pow-R Trip 7, Digitrip RMS 510, 610, 810, 910, Digitrip OPTIM 750 and 1050, LS - Long-Time and Short-Time trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
SHD1G2Q3D
SHD1G2Q3D
General Electric - Insulated Case
SHD1G2Q3D, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 225A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
E4L-A36-3P-1200A-DO-EO-LSIG
E4L-A36-3P-1200A-DO-EO-LSIG
ABB - Insulated Case
E4L-A36-3P-1200A-DO-EO-LSIG, ABB, EMax, type , 3P, 3PH, 3600A frame, 1200A rating plug, 600V, 125kA@480V, Draw-Out, electrically operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SSB4G7H6U
SSB4G7H6U
General Electric - Insulated Case
SSB4G7H6U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, RELT, modbus communication & relays features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD2G584Q
SHD2G584Q
General Electric - Insulated Case
SHD2G584Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication, relays & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNXNYNANSX
MDN4083LEA0822NMNXNYNANSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNXNYNANSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHD3G664R
SHD3G664R
General Electric - Insulated Case
SHD3G664R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNH2EHNMPX
MDN4083LEA0122NMNH2EHNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNH2EHNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNK4EHNMWX
MDN4083LEA0422NMNK4EHNMWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK4EHNMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
K108LSIGZ2PM
K108LSIGZ2PM
General Electric - Trip Units And Programmers
K108LSIGZ2PM, General Electric, MicroVersaTrip PM, trip units and programmers, 800A current sensor rating, Solid State electronic, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, ground fault and short-time zone-selective interlock, protective relays, metering and communications, suitable for use with 1600A frame WavePro WPS,WPH,WPF,WPX low voltage power circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNN4YNRNPX
MDN4083LEA0722NMNN4YNRNPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4YNRNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNE2EHNMWX
MDN4083LEA0722NMNE2EHNMWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNE2EHNMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNXNNNACPX
MDN4083LEA0722NMNXNNNACPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNXNNNACPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNC2ENHMWX
MDN4083LEA0822NMNC2ENHMWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2ENHMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SSD2G5N3Q
SSD2G5N3Q
General Electric - Insulated Case
SSD2G5N3Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0422NMNR2ENKNAX
MDN4083LEA0422NMNR2ENKNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR2ENKNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA31F16N2240
MPA31F16N2240
General Electric - Insulated Case
MPA31F16N2240, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 48V dc motor operator, 48V dc closing coil, 220/250V dc/ac shunt trip, 3P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNCNNNKCSX
MDN4083LEA0522NMNCNNNKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNCNNNKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNF2NHNCPX
MDN4083LEA0422NMNF2NHNCPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF2NHNCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNCNYNCDWX
MDN4083LEA0422NMNCNYNCDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNYNCDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNA4YNYCCX
MDN4083LEA0622NMNA4YNYCCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNA4YNYCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price