Limited Stock
SHB6G9J6W
SHB6G9J6W
General Electric - Insulated Case
SHB6G9J6W, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, modbus communication & relays features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD3G6X1M
SSD3G6X1M
General Electric - Insulated Case
SSD3G6X1M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNHNENRCSX
MDN4083LEA0222NMNHNENRCSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNHNENRCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNJNENYDWX
MDN4083LEA0222NMNJNENYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNJNENYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SSD2G5H9U
SSD2G5H9U
General Electric - Insulated Case
SSD2G5H9U, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & relays features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB2G5F6N
SSB2G5F6N
General Electric - Insulated Case
SSB2G5F6N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNN2NNKMAX
MDN4083LEA0322NMNN2NNKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN2NNKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
DA-75-EO-DO-LIG
DA-75-EO-DO-LIG
Westinghouse - Air
DA-75-EO-DO-LIG, Westinghouse, DA Series, type , 3000A frame size, electrically operated/Draw-Out, 3P, 3PH, 3000A max current sensor rating, 600V, 75kA@480V, originally supplied with electro-mechanical oil dashpot trip device but can be retrofitted with a modern Solid State electronic trip unit with LIG - Long-Time, Instantaneous and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
DS416-800A-MO-DO-LI
DS416-800A-MO-DO-LI
Cutler Hammer - Air
DS416-800A-MO-DO-LI, Cutler Hammer, DS Series, type , 1600A frame size, 400-1000A trip range, manually operated/Draw-Out, 3P, 3PH, 800A, 600V, 50kA@480V, available with solid state trip unit, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNC2NNCCSX
MDN4083LEA0522NMNC2NNCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNC2NNCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNK2ENHDCX
MDN4083LEA0822NMNK2ENHDCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNK2ENHDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
NZMN3-4-A500/320
NZMN3-4-A500/320
Klockner Moeller - Molded Case
NZMN3-4-A500/320, Eaton, Klockner Moeller, NZM3 Series, type , 4P, 3PH, 690V, 500A, 50kA@415V, normal switching capacity, Bolt-On/fixed mounting, with screw terminals, Thermal Magnetic, molded case circuit breakers, IEC rated/UL listed
From Get Price
Limited Stock
MDN4083LEA0822NMNR2ENANSX
MDN4083LEA0822NMNR2ENANSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNR2ENANSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
RLE-800A-EO-BO-LSG
RLE-800A-EO-BO-LSG
Siemens-Allis - Air
RLE-800A-EO-BO-LSG, Siemens-Allis, RL Series, type , 800A frame size, electrically operated/stationary mounted, 3P, 3PH, 150-800A current sensor rating, 600V, 65kA@480V, originally supplied with StaticTrip III RMS trip device but can also be retrofitted with a modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNJ2ENCCSX
MDN4083LEA0522NMNJ2ENCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ2ENCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSB4G7J8W
SSB4G7J8W
General Electric - Insulated Case
SSB4G7J8W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & relays features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNRNNCNNAX
MDN4083LEA0722NMNRNNCNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNRNNCNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
PEBN3ATGR0150
PEBN3ATGR0150
General Electric - Molded Case
PEBN3ATGR0150, General Electric, GuardEon, type , 3PH, 3P, 600V, 150A, 65kA@480V, 100% rated, front connection/Feed-Thru, toggle mechanism, complete with GTM interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
SHD6G9F9W
SHD6G9F9W
General Electric - Insulated Case
SHD6G9F9W, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering & modbus communication features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNENECNMCX
MDN4083LEA0122NMNENECNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNENECNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNA4NNRCPX
MDN4083LEA0322NMNA4NNRCPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA4NNRCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNG4ECKNPX
MDN4083LEA0222NMNG4ECKNPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG4ECKNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & Kirk keylock & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNE4YNHDCX
MDN4083LEA0722NMNE4YNHDCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNE4YNHDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
DSLII-308-600A-MO-DO-LSIG
DSLII-308-600A-MO-DO-LSIG
Cutler Hammer - Air
DSLII-308-600A-MO-DO-LSIG, Cutler Hammer, DSLII Series, type , 800A frame size, manually operated/Draw-Out, 3P, 3PH, 600A, 600V, 200kA@480V with current limiters, available with Digitrip RMS solid state trip unit, Solid State electronic, air circuit breakers