1. Home / 
  2. square d breaker

SORT BY
Limited Stock
SSF5G8W7R
SSF5G8W7R
General Electric - Insulated Case
SSF5G8W7R, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
E6L-A50-3P-2000A-BO-EO-LI
E6L-A50-3P-2000A-BO-EO-LI
ABB - Insulated Case
E6L-A50-3P-2000A-BO-EO-LI, ABB, EMax, type , 3P, 3PH, 5000A frame, 2000A rating plug, 600V, 150kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SHD1G3B1L
SHD1G3B1L
General Electric - Insulated Case
SHD1G3B1L, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT, & modbus communication features and 700A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
FS360050B
FS360050B
Cutler Hammer - Molded Case
FS360050B, Cutler Hammer, FS Series, type , 3P, 3PH, 50A, 600V, 40°C, 14kA@480V, standard interrupting capacity, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNENNNKMPX
MDN4083LEA0622NMNENNNKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNENNNKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNG2ENLCPX
MDN4083LEA0222NMNG2ENLCPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG2ENLCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MPA31F16W2240
MPA31F16W2240
General Electric - Insulated Case
MPA31F16W2240, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 48V dc motor operator, 48V dc closing coil, 220/250V dc/ac shunt trip, 3P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
NGS308039EVH09
NGS308039EVH09
Eaton - Molded Case
NGS308039EVH09, Cutler Hammer, Eaton, Series G, type , 3P, 3PH, 800A, 600V, 50kA@480V, standard interrupting capacity, for Naval applications 50°C, not UL listed, Bolt-On, complete with Digitrip RMS 310+ trip, ALSIG - Arcflash Reduction, Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and imperial tapped line/load conductors, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SHB2G5N9Q
SHB2G5N9Q
General Electric - Insulated Case
SHB2G5N9Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communication & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNJNNNNNPX
MDN4083LEA0122NMNJNNNNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJNNNNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNRNYNRDSX
MDN4083LEA0122NMNRNYNRDSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNRNYNRDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
GNH3125T35WP01
GNH3125T35WP01
Cutler Hammer - Molded Case
GNH3125T35WP01, Cutler Hammer, Series G, type , 1250A frame, 3P, 3PH, 600V, 65kA@480V, high interrupting capacity, Bolt-On, complete with Digitrip RMS 310 trip, LSG - Long-Time, Short-Time and Ground Fault trip functions, 1250A fixed rating plug, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
GUT45F16BLA
GUT45F16BLA
General Electric - Part And Accessory
GUT45F16BLA, General Electric, EntellEon, type , Panelboard Assemblies, gutter cover, Type 1 door, suitable for use with EntellEon 45 width enclosure with offset orientation and 16X bus height with bolted lugs
From Get Price
Limited Stock
FNT409632RSG5CB
FNT409632RSG5CB
General Electric - Part And Accessory
FNT409632RSG5CB, General Electric, EntellEon, type , panelboard front, Type 1 non-vented, bottom, 40 enclosure width
From Get Price
Limited Stock
MDN4083LEA0722NMNK4ENHCSX
MDN4083LEA0722NMNK4ENHCSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNK4ENHCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNENYNYNAX
MDN4083LEA0822NMNENYNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNENYNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SPD347Y10SE01
SPD347Y10SE01
General Electric - Part And Accessory
SPD347Y10SE01, General Electric, EntellEon, type , Surge Protection device kit, 347Y, 100kA max single impulse surge current, SE disconnect device, SPD Type 1, suitable for use with EntellEon panelboards and can be mounted on the offset side of a 40 or 45 wide enclosure and interior frame
From Get Price
Limited Stock
MDN4083LEA0322NMNA2NNKDCX
MDN4083LEA0322NMNA2NNKDCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA2NNKDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSB6G9W9U
SSB6G9W9U
General Electric - Insulated Case
SSB6G9W9U, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication, relays & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF1G2Z9F
SHF1G2Z9F
General Electric - Insulated Case
SHF1G2Z9F, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & ZSI features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
TJK436TM2225
TJK436TM2225
General Electric - Trip Units And Programmers
TJK436TM2225, General Electric, J600 Line, type , J600 Line, interchangeable trip, Magnetic Only, I - Instantaneous protection only, rated for 225A, 1200-4000 mag range, suitable for 400A frame- TJK,THJK molded case circuit breaker frame types
From Get Price
Limited Stock
MDN4083LEA0322NMNE4ENADAX
MDN4083LEA0322NMNE4ENADAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNE4ENADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA41F25V3010
MPA41F25V3010
General Electric - Insulated Case
MPA41F25V3010, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 110/130V dc/ac motor operator and 24/30V dc shunt trip, 4P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNF4NNADCX
MDN4083LEA0122NMNF4NNADCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF4NNADCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price