1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0222NMNH4NNYCSX
MDN4083LEA0222NMNH4NNYCSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH4NNYCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNXNNNRDWX
MDN4083LEA0422NMNXNNNRDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNXNNNRDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
S281UC-Z2
S281UC-Z2
ABB - Molded Case
S281UC-Z2, ABB, S 280 Series, type , 1P, 1PH, 2A, 500Vdc, 4.5kA@500Vdc, standard interrupting capacity, current limiting, DIN rail mounted, Feed-Thru, suitable for reverse feed, UL/CSA/IEC approval, branch circuit protection, Z trip characteristic, Thermal Magnetic trip functions, Thermal Magnetic, miniature molded case circuit breakers and supplemental protectors
From Get Price
Limited Stock
WLL2D308GR
WLL2D308GR
Siemens - Insulated Case
WLL2D308GR, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 800A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU755 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 400A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
DSII-508-800A-MO-DO-LSI
DSII-508-800A-MO-DO-LSI
Cutler Hammer - Air
DSII-508-800A-MO-DO-LSI, Cutler Hammer, DSII Series, type , 800A frame size, manually operated/Draw-Out, 3P, 3PH, 800A, 600V, 50kA@480V, available with Digitrip RMS solid state trip unit, Solid State electronic, low voltage power air circuit breakers
From Get Price
Limited Stock
SHB2G4F6N
SHB2G4F6N
General Electric - Insulated Case
SHB2G4F6N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G6L3N
SSD4G6L3N
General Electric - Insulated Case
SSD4G6L3N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB3G6F2T
SSB3G6F2T
General Electric - Insulated Case
SSB3G6F2T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering & modbus communication features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
LGE3630NNVH09
LGE3630NNVH09
Cutler Hammer - Molded Case
LGE3630NNVH09, FRAME ONLY, Cutler Hammer, Series G, type , 3P, 3PH, 630A, 600V, 25kA@480V, standard interrupting capacity, for Naval applications 50?, not UL listed, Bolt-On, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
140G-H15H4-C25
140G-H15H4-C25
Allen-Bradley - Molded Case
140G-H15H4-C25, Allen-Bradley, Bulletin 140G, type , 4P, 3PH, 25A, 600V, 150kA@480V, high interrupting capacity, Bolt-On, complete with non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNK2EHNNCX
MDN4083LEA0322NMNK2EHNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK2EHNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNCNYNKDAX
MDN4083LEA0422NMNCNYNKDAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNYNKDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
372D524G03
372D524G03
Eaton - Trip Units And Programmers
372D524G03, Eaton, Naval, Thermal Magnetic trip units and programmers, type -A1601, 3P, 1000A, 500Vac, 2000-6000 instantaneous trip setting, LI - Long-Time and Instantaneous trip functions, suitable for use with AQB-A1601,NQB-A1601 circuit breakers for naval shipboard use
From Get Price
Limited Stock
MDN4083LEA0122NMNCNNNCMCX
MDN4083LEA0122NMNCNNNCMCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNCNNNCMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHB5G889R
SHB5G889R
General Electric - Insulated Case
SHB5G889R, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication, relays & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G7M41
SSD4G7M41
General Electric - Insulated Case
SSD4G7M41, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT, modbus communication & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNG4ENADAX
MDN4083LEA0522NMNG4ENADAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG4ENADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
CFV3100L
CFV3100L
Challenger - Molded Case
CFV3100L, Challenger, CFV Series, type , 3P, 3PH, 100A, 600V, 100kA@480V, current limiting, 40°C, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNX4ENYCAX
MDN4083LEA0422NMNX4ENYCAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNX4ENYCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
WLL2F316BY
WLL2F316BY
Siemens - Insulated Case
WLL2F316BY, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 1600A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU755 programmer + WLGFM76 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 225A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNE4YNRDPX
MDN4083LEA0822NMNE4YNRDPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNE4YNRDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNA4ENLNCX
MDN4083LEA0722NMNA4ENLNCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNA4ENLNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNNNENAMAX
MDN4083LEA0522NMNNNENAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNNNENAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, operations counter, Solid State, low voltage power insulated case circuit breakers, shipped without cassette, unwired
From Get Price
Limited Stock
WLS2F308KY
WLS2F308KY
Siemens - Insulated Case
WLS2F308KY, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 800A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU755 programmer + WLGFM76 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 600A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price