Limited Stock
MDN4083LEA0422NMNKNENKMSX
MDN4083LEA0422NMNKNENKMSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNKNENKMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MPA41F1001030
MPA41F1001030
General Electric - Insulated Case
MPA41F1001030, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 24/30V dc motor operator and 110/130V dc/ac shunt trip, 4P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
708471-T14
708471-T14
ABB - Under Voltage Release
708471-T14, ABB, BBC, ITE, K-Line, Undervoltage Trip Device, Time Delay Trip, 48VDC, suitable for All K-3000/K-4000
From Get Price
Limited Stock
SHD1G223F
SHD1G223F
General Electric - Insulated Case
SHD1G223F, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communication & ZSI features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB1G1Z8B
SHB1G1Z8B
General Electric - Insulated Case
SHB1G1Z8B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNANYNHMSX
MDN4083LEA0122NMNANYNHMSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNANYNHMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
E4V-A32-3P-2000A-DO-EO-LI
E4V-A32-3P-2000A-DO-EO-LI
ABB - Insulated Case
E4V-A32-3P-2000A-DO-EO-LI, ABB, EMax, type , 3P, 3PH, 3200A frame, 2000A rating plug, 600V, 100kA@480V, Draw-Out, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
PEEB3ATAL0125
PEEB3ATAL0125
General Electric - Molded Case
PEEB3ATAL0125, General Electric, GuardEon, type , 3PH, 3P, 600V, 38-125A, 18kA@480V, 100% UL rated, front connection/Feed-Thru, toggle mechanism, complete with PremEon G interchangeable trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
DS206E-300A-EO-BO-LSI
DS206E-300A-EO-BO-LSI
Cutler Hammer - Air
DS206E-300A-EO-BO-LSI, Cutler Hammer, DS Series, type , 800A frame size, 50-800A trip range, electrically operated/Bolt-On, 3P, 3PH, 300A current sensor rating, 600V, 65kA@480V, extra interrupting, available with solid state trip unit, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
SKSS3408L3N8
SKSS3408L3N8
General Electric - Molded Case
SKSS3408L3N8, General Electric, Spectra Series, type , 3P, 3PH, 800A, 480V, 100kA@480V, standard interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIZ - Long-Time, Short-Time, Instantaneous and ZSI trip functions with extended instantaneous, advanced metering + modbus + waveform capture + relays, Solid State with RELT and neutral protection, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNHNENRMPX
MDN4083LEA0522NMNHNENRMPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNHNENRMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNR4NCNDCX
MDN4083LEA0122NMNR4NCNDCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNR4NCNDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNX4YHNNSX
MDN4083LEA0222NMNX4YHNNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNX4YHNNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSF5G8J91
SSF5G8J91
General Electric - Insulated Case
SSF5G8J91, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication & relays features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD2G567P
SSD2G567P
General Electric - Insulated Case
SSD2G567P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNANYNYDCX
MDN4083LEA0222NMNANYNYDCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNANYNYDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNHNNNKNWX
MDN4083LEA0822NMNHNNNKNWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNHNNNKNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
LG3450WS89
LG3450WS89
Cutler Hammer - Molded Case
LG3450WS89, Westinghouse, Cutler Hammer, Eaton, Series G, type , 3P, 3PH, 450A, 600V, 14kA@480V, standard interrupting capacity, Bolt-On, suitable for reverse feed applications, magnetic pickup range 500-2500, complete with right-pole mounted 48-60Vdc, 50/60Hz rear mount shunt trip, I - Instantaneous trip functions, lugs not included, Solid State electronic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNC4ENNCCX
MDN4083LEA0122NMNC4ENNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC4ENNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNR2ENHMAX
MDN4083LEA0522NMNR2ENHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR2ENHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHF1G3J2H
SHF1G3J2H
General Electric - Insulated Case
SHF1G3J2H, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, modbus communication & relays features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNENNNLDSX
MDN4083LEA0522NMNENNNLDSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNENNNLDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNA4NNHDPX
MDN4083LEA0222NMNA4NNHDPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNA4NNHDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNKNYNKMPX
MDN4083LEA0822NMNKNYNKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNKNYNKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price