1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
NDG2B110L
NDG2B110L
Siemens - Molded Case
NDG2B110L, Siemens, VL Series, type , 2P, 1PH, 110A, 600V, 35kA@480V, standard interrupting capacity, 40ºC, Feed-Thru, complete with LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNGNNNYCWX
MDN4083LEA0622NMNGNNNYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNGNNNYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNE2YHNDWX
MDN4083LEA0122NMNE2YHNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNE2YHNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
LV432539
LV432539
Schneider Electric - Molded Case
LV432539, Schneider Electric, Compact NSX, type , PH, P, V, A, , , complete with trip functions, , molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNX2NNYNCX
MDN4083LEA0622NMNX2NNYNCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX2NNYNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNENNNHCSX
MDN4083LEA0122NMNENNNHCSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNENNNHCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNN4NCNCAX
MDN4083LEA0522NMNN4NCNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNN4NCNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSF4G6E2U
SSF4G6E2U
General Electric - Insulated Case
SSF4G6E2U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNGNYNCCSX
MDN4083LEA0722NMNGNYNCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNGNYNCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEF36600A4
SEF36600A4
Schneider Electric - Insulated Case
SEF36600A4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHF361000LSGES5E8
SEHF361000LSGES5E8
Schneider Electric - Insulated Case
SEHF361000LSGES5E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SSD3G6A2U
SSD3G6A2U
General Electric - Insulated Case
SSD3G6A2U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering & RELT features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MP30-3P-2000A
MP30-3P-2000A
Merlin Gerin - Insulated Case
MP30-3P-2000A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame includes 2000A, 2500A or 3000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SSD6G9N2U
SSD6G9N2U
General Electric - Insulated Case
SSD6G9N2U, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G3W1K
SSD1G3W1K
General Electric - Insulated Case
SSD1G3W1K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communication, relays & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNKNNNRMWX
MDN4083LEA0122NMNKNNNRMWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNKNNNRMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SEHF36300ES7E8
SEHF36300ES7E8
Square D - Insulated Case
SEHF36300ES7E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 300A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
WLL1D312MH
WLL1D312MH
Siemens - Insulated Case
WLL1D312MH, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 1200A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU745 programmer + WLLCD48 LCD display + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 700A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SEHF363200LIGES8D8
SEHF363200LIGES8D8
Schneider Electric - Insulated Case
SEHF363200LIGES8D8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNK4ENRDAX
MDN4083LEA0122NMNK4ENRDAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK4ENRDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SEHD361600LSGES8
SEHD361600LSGES8
Square D - Insulated Case
SEHD361600LSGES8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1600A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNCNNNLDCX
MDN4083LEA0522NMNCNNNLDCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNCNNNLDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PGL36120U74BE1RE10
PGL36120U74BE1RE10
Square D - Molded Case
PGL36120U74BE1RE10, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1200A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Feed-Thru, complete with door mounted standard black handle, micrologic interchangeable harmonic 6.0H trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
PDG32N0600E3MK
PDG32N0600E3MK
Eaton - Molded Case
PDG32N0600E3MK, Cutler Hammer, Eaton, Power Defense, type , 1PH, 2P, 600V, 600A, 85kA@480V, Bolt-On, line side lug terminals, complete with PXR20 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price