1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
SEHF361800LIGES8F4
SEHF361800LIGES8F4
Square D - Insulated Case
SEHF361800LIGES8F4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1800A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0722NMNXNNNNNWX
MDN4083LEA0722NMNXNNNNNWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNXNNNNNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters and pre-wired
From Get Price
Limited Stock
SEF36400LSGES3C4
SEF36400LSGES3C4
Schneider Electric - Insulated Case
SEF36400LSGES3C4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNNNENRMAX
MDN4083LEA0822NMNNNENRMAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNNNENRMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Ronis keylock, Solid State, low voltage power insulated case circuit breakers, shipped without cassette, unwired
From Get Price
Limited Stock
PDG32F0600D5YN
PDG32F0600D5YN
Eaton - Molded Case
PDG32F0600D5YN, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 600A, 25kA@480V, Bolt-On, no lug terminals, complete with PXR20D ARMS trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and Modbus RTU, CAM Link, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
SEF36400S3
SEF36400S3
Square D - Insulated Case
SEF36400S3, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 400A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 48VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
FP50-2000A-EO-BO-LI
FP50-2000A-EO-BO-LI
Federal Pacific - Air
FP50-2000A-EO-BO-LI, Federal Pacific, FP Series, type , 2000A frame size, electrically operated/Bolt-On, 3P, 3PH, 2000A, 600V, 50kA@480V, originally supplied with electro-mechanical TD-1 or TD-2 overcurrent trip device, but can also be retrofitted with modern Solid State electronic trip unit with LI - Long-Time and Instantaneous trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
LGU440035GVH09
LGU440035GVH09
Cutler Hammer - Molded Case
LGU440035GVH09, Cutler Hammer, Series G, type , 3P, 3PH, 400A, 600V, 150kA@480V, current limiting, for Naval applications 50°C, not UL listed, Feed-Thru, complete with interchangeable trip, LSG - Long-Time, Short-Time and Ground Fault trip functions and line & load side lug terminals, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
SED363200LIGES7D8
SED363200LIGES7D8
Square D - Insulated Case
SED363200LIGES7D8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PJL36120CU74BE1AC
PJL36120CU74BE1AC
Square D - Molded Case
PJL36120CU74BE1AC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1200A, 600V, 65kA@480V, UL listed, high interrupting capacity, Feed-Thru, 100% rated, complete with 3A/3B auxiliary switch, micrologic interchangeable harmonic 6.0H trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNC2NNNMAX
MDN4083LEA0622NMNC2NNNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC2NNNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SEHF36250LSIES5A8
SEHF36250LSIES5A8
Schneider Electric - Insulated Case
SEHF36250LSIES5A8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 250A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNA2YNKNAX
MDN4083LEA0522NMNA2YNKNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA2YNKNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSD6G9N82
SSD6G9N82
General Electric - Insulated Case
SSD6G9N82, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0422NMNH2ENYMWX
MDN4083LEA0422NMNH2ENYMWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH2ENYMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
JGE3090FAGVH09
JGE3090FAGVH09
Cutler Hammer - Molded Case
JGE3090FAGVH09, Cutler Hammer, Series G, type , 3P, 3PH, 90A, 600V, 25kA@480V, standard interrupting capacity, for Naval applications 50°C, not UL listed, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNR2YNYCCX
MDN4083LEA0622NMNR2YNYCCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR2YNYCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SEHD36350LIGET5
SEHD36350LIGET5
Schneider Electric - Insulated Case
SEHD36350LIGET5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MPA41F12V0240
MPA41F12V0240
General Electric - Air
MPA41F12V0240, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 48V dc closing coil and 220/250V dc/ac shunt trip, 4P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
TS253T18
TS253T18
General Electric - Trip Units And Programmers
TS253T18, General Electric, Power Break I, type , interchangeable Dual Magnetic trip units and programmers, LI - Long-Time and Instantaneous trip functions, rated for 1800A, 3-pole, suitable for Power Break I manually operated 2500A frame- TS,TPS,THS frames, insulated case circuit breakers
From Get Price
Limited Stock
PEEB3ATEJ0150
PEEB3ATEJ0150
General Electric - Molded Case
PEEB3ATEJ0150, General Electric, GuardEon, type , 3PH, 3P, 600V, 45-150A, 18kA@480V, 100% UL rated, front connection/Feed-Thru, toggle mechanism, complete with PremEon G advanced metering interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
AKR-10S-75
AKR-10S-75
General Electric - Air
AKR-10S-75, General Electric, AKR Series, type , 3200A frame, 3PH, 3P, 635Vac, 3200A sensor rating, 65kA@508V, Bolt-On/stationary, available either mechanically or electrically operated, with MVT+, MVT PM programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, optional functions available, Solid State electronic, low voltage air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNRNNNRMSX
MDN4083LEA0722NMNRNNNRMSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNRNNNRMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNR2YNYCCX
MDN4083LEA0322NMNR2YNYCCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNR2YNYCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price