1. Home / 
  2. square d breaker

SORT BY
Limited Stock
XT3SQ3100AFF000XXX
XT3SQ3100AFF000XXX
ABB - Molded Case
XT3SQ3100AFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 100A, 600V, 10kA@600Y/347V, Thermal Magnetic Fixed (TMF), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price
Limited Stock
SHT-A-120V
SHT-A-120V
LS Electric - Shunt Trip
SHT-A-120V, LS Electric, shunt trip, 130 - 130V AC/DC, suitable for use with UTE100 frame molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNJ2YNCDCX
MDN4083LEA0322NMNJ2YNCDCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNJ2YNCDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNRNNNLMSX
MDN4083LEA0722NMNRNNNLMSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNRNNNLMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSD2G5X4Q
SSD2G5X4Q
General Electric - Insulated Case
SSD2G5X4Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG32G0400E2ZN
PDG32G0400E2ZN
Eaton - Molded Case
PDG32G0400E2ZN, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 400A, 35kA@480V, Bolt-On, no lug terminals, complete with PXR20 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions with ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0322NMNC4ENKCAX
MDN4083LEA0322NMNC4ENKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNC4ENKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHF1G1Q2B
SHF1G1Q2B
General Electric - Insulated Case
SHF1G1Q2B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT, modbus communication & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0422NMNF4ECNMCX
MDN4083LEA0422NMNF4ECNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF4ECNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PEEC4ATAK0125
PEEC4ATAK0125
General Electric - Molded Case
PEEC4ATAK0125, General Electric, GuardEon, type , 3PH, 4P, 600V, 38-125A, 25kA@480V, 100% UL rated, front connection/Feed-Thru, toggle mechanism, complete with PremEon G interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
SHF4G6F2N
SHF4G6F2N
General Electric - Insulated Case
SHF4G6F2N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB4G6B7U
SSB4G6B7U
General Electric - Insulated Case
SSB4G6B7U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, RELT & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNENNNYDAX
MDN4083LEA0122NMNENNNYDAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNENNNYDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNA2YNRDSX
MDN4083LEA0822NMNA2YNRDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA2YNRDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSB2G592Q
SSB2G592Q
General Electric - Insulated Case
SSB2G592Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNK4YNRMAX
MDN4083LEA0222NMNK4YNRMAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK4YNRMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNG4ENKDCX
MDN4083LEA0522NMNG4ENKDCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG4ENKDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MPA41F0804300
MPA41F0804300
General Electric - Insulated Case
MPA41F0804300, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 220/250V dc/ac motor operator and 110/130V dc/ac closing coil, 4P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
MPA31F2003150
MPA31F2003150
General Electric - Insulated Case
MPA31F2003150, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 110/130V dc/ac motor operator, 24/30V dc closing coil and 380/400V ac shunt trip, 3P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNCNYNYDSX
MDN4083LEA0122NMNCNYNYDSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNCNYNYDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
B210LSIGD
B210LSIGD
General Electric - Trip Units And Programmers
B210LSIGD, General Electric, MicroVersaTrip Plus, type , trip units and programmers, 1000A current sensor rating, Solid State electronic, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, ground fault defeatable, trip functions, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNENENADCX
MDN4083LEA0322NMNENENADCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNENENADCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNCNECNDWX
MDN4083LEA0522NMNCNECNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNCNECNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNXNENRMCX
MDN4083LEA0822NMNXNENRMCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNXNENRMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price