1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0722NMNN2NNYCCX
MDN4083LEA0722NMNN2NNYCCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN2NNYCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNENENCCSX
MDN4083LEA0122NMNENENCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNENENCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNHNYNCMCX
MDN4083LEA0822NMNHNYNCMCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNHNYNCMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SED361800LSES5D5
SED361800LSES5D5
Schneider Electric - Insulated Case
SED361800LSES5D5, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1800A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PDG62N2000P5WN
PDG62N2000P5WN
Eaton - Molded Case
PDG62N2000P5WN, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 2000A, 85kA@480V, Bolt-On, no terminals, complete with PXR25 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault with ARMS trip functions with relays, modbus & ZSI option, Solid State electronic, molded case circuit breakers; globally rated
From Get Price
Limited Stock
SEF361600LIGES5E8
SEF361600LIGES5E8
Square D - Insulated Case
SEF361600LIGES5E8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SED362000LIES9C8
SED362000LIES9C8
Schneider Electric - Insulated Case
SED362000LIES9C8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PJF36025U43BYP
PJF36025U43BYP
Schneider Electric - Molded Case
PJF36025U43BYP, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 250A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with fixed handle padlocking device, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNR4NNHNCX
MDN4083LEA0422NMNR4NNHNCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR4NNHNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PDG34P0125D5WK
PDG34P0125D5WK
Cutler Hammer - Molded Case
PDG34P0125D5WK, Cutler Hammer, Eaton, Power Defense, type , 3PH, 4P, 600V, 125A, 100kA@480V, Bolt-On, line side lug terminals, complete with PXR20D ARMS trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and Modbus RTU, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0422NMNR4YNYDCX
MDN4083LEA0422NMNR4YNYDCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR4YNYDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
S47432
S47432
Square D - Auxiliary
S47432, Square D, Masterpact, type , auxiliary, 1A/1B ready-to-close contact (PF), suitable for use with T-frame drawout style NT frame insulated case circuit breakers
From Get Price
Limited Stock
EB3100SN
EB3100SN
Cutler Hammer - Molded Case
EB3100SN, Cutler Hammer, Westinghouse, AB DE-ION, type , 3P, 3PH, 100A, 240V, 10kA@240V, standard interrupting capacity, Bolt-On, NA - No Overcurrent Protection, complete with Saf-T-Vue, load side lug terminals, Non-Automatic switch, molded case circuit breakers; these switches are now obsolete; however, we still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNC4NNRNWX
MDN4083LEA0822NMNC4NNRNWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC4NNRNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNA2NHNDAX
MDN4083LEA0522NMNA2NHNDAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA2NHNDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SEF361200LSGB4
SEF361200LSGB4
Square D - Insulated Case
SEF361200LSGB4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHD362000LSIES8D4
SEHD362000LSIES8D4
Schneider Electric - Insulated Case
SEHD362000LSIES8D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
WLS2D308CW
WLS2D308CW
Siemens - Insulated Case
WLS2D308CW, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 800A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU755 programmer + WLGFA76 ground fault module, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 250A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNE4NNKDSX
MDN4083LEA0522NMNE4NNKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE4NNKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SED36400LSIES7C8
SED36400LSIES7C8
Square D - Insulated Case
SED36400LSIES7C8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete
From Get Price
Limited Stock
E1030VL
E1030VL
Westinghouse - Molded Case
E1030VL, Westinghouse, E Series, type , 1P, 1PH, 30A, 120V, 7kA@120V, standard interrupting capacity, 50°C, Feed-Thru, complete with LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers; these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PDG33G0175VFAN
PDG33G0175VFAN
Cutler Hammer - Molded Case
PDG33G0175VFAN, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 175A, 35kA@480V, Bolt-On, lug terminals not included, complete with LI - Long-Time and Instantaneous trip functions, 50ºC Thermal Magnetic, molded case circuit breakers; CSA, IEC, UL, CCC certifications; non-UL listed
From Get Price
Limited Stock
MPA31F12W1400
MPA31F12W1400
General Electric - Insulated Case
MPA31F12W1400, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc motor operator and 220/250V dc/ac closing coil, 3P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNJ2YNKMCX
MDN4083LEA0522NMNJ2YNKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ2YNKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price