1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0722NMNE4NCNMAX
MDN4083LEA0722NMNE4NCNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNE4NCNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNHNNNKMSX
MDN4083LEA0522NMNHNNNKMSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNHNNNKMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
KDON-600-MO-DO-LSG
KDON-600-MO-DO-LSG
ABB - Air
KDON-600-MO-DO-LSG, ABB, K-Line, type , 600A fused frame size, manually operated/Draw-Out, 3P, 3PH, 600A, 600V, 200kA@480V, originally supplied with OD electro-mechanical overcurrent trip device, SS, MPS or MPS-C trip device but can also be retrofitted with a modern Solid State electronic trip unit with LSG - Long-Time, Short-Time and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
RMS-TSG-TZ-CNP
RMS-TSG-TZ-CNP
Siemens - Trip Units And Programmers
RMS-TSG-TZ-CNP, Siemens, Static Trip III, type current sensing, programmable to any amperage requirement 150A-5000A, 600V, 3P, LCD display, LSG - Long-Time, Short-Time and Ground Fault trip functions, zone interlocking and communications capability, neutral current and power metering, suitable for use with type RL,RLE,RLI,RLF low voltage power circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNANNNYNSX
MDN4083LEA0822NMNANNNYNSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNANNNYNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNX2ENHNPX
MDN4083LEA0422NMNX2ENHNPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNX2ENHNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNCNYNHMAX
MDN4083LEA0422NMNCNYNHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNYNHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
GRC320T33WP15
GRC320T33WP15
Cutler Hammer - Molded Case
GRC320T33WP15, Cutler Hammer, Series G, type , 2000A frame, 3P, 3PH, 600V, 100kA@480V, very high interrupting capacity, Bolt-On, complete with Digitrip RMS 310 trip, LS - Long-Time and Short-Time trip functions, 1000A fixed rating plug, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNANYNKNPX
MDN4083LEA0122NMNANYNKNPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNANYNKNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSB4G4B1N
SSB4G4B1N
General Electric - Insulated Case
SSB4G4B1N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNJ4ENYCPX
MDN4083LEA0522NMNJ4ENYCPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ4ENYCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNJNENYNSX
MDN4083LEA0322NMNJNENYNSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNJNENYNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSB4G6N6M
SSB4G6N6M
General Electric - Insulated Case
SSB4G6N6M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, modbus communcation & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
GB102L4XXXRXXXX
GB102L4XXXRXXXX
General Electric - Trip Units And Programmers
GB102L4XXXRXXXX, General Electric, EntelliGuard replacement trip units and programmers, 3P, 600V, 200A sensor rating, 800A frame rating, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, suitable for use with Power Break II SSB,SHB,SHD,SHF,SSD,SSF insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNR4YNLCAX
MDN4083LEA0722NMNR4YNLCAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR4YNLCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNHNYNKMAX
MDN4083LEA0822NMNHNYNKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNHNYNKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNKNNNLDCX
MDN4083LEA0422NMNKNNNLDCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNKNNNLDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions,load side lug terminals, mechanical trip indicator, Castell key interlock & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MPA41F16V0024
MPA41F16V0024
General Electric - Insulated Case
MPA41F16V0024, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 48V dc shunt trip and 380/440V ac undervoltage trip, 4P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNC2NHNMCX
MDN4083LEA0222NMNC2NHNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNC2NHNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNKNYNKMSX
MDN4083LEA0722NMNKNYNKMSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNKNYNKMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNXNEMNNSX
MDN4083LEA0522NMNXNEMNNSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNXNEMNNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNX4ECNDWX
MDN4083LEA0222NMNX4ECNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNX4ECNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNCNECNMSX
MDN4083LEA0822NMNCNECNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNCNECNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNF4NNKCSX
MDN4083LEA0722NMNF4NNKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNF4NNKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price