1. Home / 
  2. square d breaker

SORT BY
Limited Stock
SHD1G388J
SHD1G388J
General Electric - Insulated Case
SHD1G388J, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MPA31F10N1010
MPA31F10N1010
General Electric - Insulated Case
MPA31F10N1010, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 24/30V dc motor operator and 24/30V dc shunt trip, 3P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SSB3G6W7N
SSB3G6W7N
General Electric - Insulated Case
SSB3G6W7N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
TQC3410
TQC3410
General Electric - Molded Case
TQC3410, General Electric, Q-Line, type , 3P, 3PH, 380V, 10A, 5kA@220V, UL listed, standard interrupting capacity, Feed-Thru, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
WLS2F308HE
WLS2F308HE
Siemens - Insulated Case
WLS2F308HE, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 800A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFA48, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 450A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNH2YNKCAX
MDN4083LEA0222NMNH2YNKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH2YNKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNHNENKMPX
MDN4083LEA0622NMNHNENKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNHNENKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNG2NNCDSX
MDN4083LEA0622NMNG2NNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNG2NNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MPA41F12V2050
MPA41F12V2050
General Electric - Insulated Case
MPA41F12V2050, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 48V dc motor operator, 380/400V ac shunt trip, 4P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
THHQB2160HM
THHQB2160HM
General Electric - Molded Case
THHQB2160HM, General Electric, Q-Line, type , 2P, 1PH, 60A, 120/240V, 22kA@120V, 40°C, UL listed, Bolt-On, Thermal Magnetic, high magnetic pickup, LI - Long-Time and Instantaneous trip functions and load side lug terminal, molded case circuit breaker
From Get Price
Limited Stock
MDN4083LEA0322NMNG4NNYCCX
MDN4083LEA0322NMNG4NNYCCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG4NNYCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNG4YNYCWX
MDN4083LEA0622NMNG4YNYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNG4YNYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNX2ENCDCX
MDN4083LEA0222NMNX2ENCDCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNX2ENCDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHB2G558R
SHB2G558R
General Electric - Insulated Case
SHB2G558R, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0422NMNCNYNLMSX
MDN4083LEA0422NMNCNYNLMSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNYNLMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNNNENCMCX
MDN4083LEA0222NMNNNENCMCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNNNENCMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, lower terminal voltage connection, castell keylock, Solid State, low voltage power insulated case circuit breakers, shipped in narrow cassette, without shutters and unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNJ4ENNDSX
MDN4083LEA0722NMNJ4ENNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ4ENNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNGNEMKNWX
MDN4083LEA0122NMNGNEMKNWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNGNEMKNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNRNNNKDCX
MDN4083LEA0422NMNRNNNKDCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNRNNNKDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSD1G221D
SSD1G221D
General Electric - Insulated Case
SSD1G221D, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 225A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG32G0250P2ML
PDG32G0250P2ML
Cutler Hammer - Molded Case
PDG32G0250P2ML, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 250A, 35kA@480V, Bolt-On, load side lug terminals, complete with PXR25 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0722NMNC2NNAMCX
MDN4083LEA0722NMNC2NNAMCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC2NNAMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNFNENKNSX
MDN4083LEA0722NMNFNENKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNFNENKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSD6G9N72
SSD6G9N72
General Electric - Insulated Case
SSD6G9N72, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price