1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0122NMNK4YNHMSX
MDN4083LEA0122NMNK4YNHMSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK4YNHMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHD1G1A4C
SHD1G1A4C
General Electric - Insulated Case
SHD1G1A4C, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & RELT features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MPA31F08W1330
MPA31F08W1330
General Electric - Insulated Case
MPA31F08W1330, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc motor operator, 110/130V dc/ac closing coil, 110/130V dc/ac shunt trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNC4NNRMSX
MDN4083LEA0322NMNC4NNRMSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNC4NNRMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHD5G859W
SHD5G859W
General Electric - Insulated Case
SHD5G859W, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNC4YNNDWX
MDN4083LEA0522NMNC4YNNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNC4YNNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNRNENYNAX
MDN4083LEA0722NMNRNENYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNRNENYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
TJS2AB1UV1
TJS2AB1UV1
General Electric - Under Voltage Release
TJS2AB1UV1, General Electric, TJS Series, type , under voltage release, UVR with 1 auxiliary switch rated for 250V, 120V, suitable for use with TJS,THJS,THJSS frame molded case circuit breakers
From Get Price
Limited Stock
MPA31F20V0040
MPA31F20V0040
General Electric - Insulated Case
MPA31F20V0040, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit and 220/250V dc/ac shunt trip, 3P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SHB1G2N3C
SHB1G2N3C
General Electric - Insulated Case
SHB1G2N3C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNF2ENNNWX
MDN4083LEA0122NMNF2ENNNWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF2ENNNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions & load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNJ2NNRCAX
MDN4083LEA0122NMNJ2NNRCAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJ2NNRCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNR4ENANSX
MDN4083LEA0422NMNR4ENANSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR4ENANSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSF4G6Q8M
SSF4G6Q8M
General Electric - Insulated Case
SSF4G6Q8M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communcation & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
TFLASA6AB1LB
TFLASA6AB1LB
General Electric - Auxiliary
TFLASA6AB1LB, General Electric, F225 Series, type , auxiliary, rated for 600Vac/250Vdc, 1A/1B, left pole mounted, lead exit from back of breaker, red/white, brown/white wires, suitable for use with F225 Series- TFL frame molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNX2YNNMCX
MDN4083LEA0622NMNX2YNNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX2YNNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSF4G6L9W
SSF4G6L9W
General Electric - Insulated Case
SSF4G6L9W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
E4H-A36-4P-1200A-BO-EO-LI
E4H-A36-4P-1200A-BO-EO-LI
ABB - Insulated Case
E4H-A36-4P-1200A-BO-EO-LI, ABB, EMax, type , 4P, 3PH, 3600A frame, 1200A rating plug, 600V, 85kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SSB1G2E2C
SSB1G2E2C
General Electric - Insulated Case
SSB1G2E2C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT & modbus communication features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
XT2SQ4040TFF000XXX
XT2SQ4040TFF000XXX
ABB - Molded Case
XT2SQ4040TFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 40A, 600V, 22kA@600V, Ekip Hi-Touch LSI, UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No
From Get Price
Limited Stock
MPA31F0804234
MPA31F0804234
General Electric - Insulated Case
MPA31F0804234, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 220/250V dc/ac motor operator, 48V dc closing coil, 110/130V dc/ac shunt trip and 380/440V ac undervoltage trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
5925-01-330-7615
5925-01-330-7615
Eaton - Molded Case
5925-01-330-7615, Eaton, Naval, type , 3P, 3PH, 160A, 500Vac, 20kA@500V, Plug-In, 400 cycle, 2020-3420 instantaneous trip setting, interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case generator circuit breakers for naval shipboard use
From Get Price
Limited Stock
SSF2G5R6T
SSF2G5R6T
General Electric - Insulated Case
SSF2G5R6T, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, modbus communication & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNKNENKDSX
MDN4083LEA0722NMNKNENKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNKNENKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price