1. Home / 
  2. square d breaker

SORT BY
Limited Stock
SSB2G518K
SSB2G518K
General Electric - Insulated Case
SSB2G518K, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MPA41F10V3150
MPA41F10V3150
General Electric - Insulated Case
MPA41F10V3150, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 110/130V dc/ac motor operator, 24/30V dc closing coil and 380/400V ac shunt trip, 4P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SSD1G3L4H
SSD1G3L4H
General Electric - Insulated Case
SSD1G3L4H, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MPA41F08N2250
MPA41F08N2250
General Electric - Insulated Case
MPA41F08N2250, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 48Vdc motor operator, 48V dc closing coil and 380/400V ac shunt trip, 4P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
Q240H01
Q240H01
Siemens - Molded Case
Q240H01 Siemens Q Series, type , 2P, 1PH, 40A, 120/240V, 22kA@240V, high interrupting capacity, with factory installed 120V auxiliary switch, Plug-In, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
XT2NQ4020AFF000XXX
XT2NQ4020AFF000XXX
ABB - Molded Case
XT2NQ4020AFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 20A, 600V, 18kA@600V, Thermal Magnetic Fixed (TMF), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No
From Get Price
Limited Stock
MPA31F08N1010
MPA31F08N1010
General Electric - Insulated Case
MPA31F08N1010, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 24/30V dc motor operator and 24/30V dc shunt trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNF4ECNCCX
MDN4083LEA0722NMNF4ECNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNF4ECNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNJNENRDWX
MDN4083LEA0822NMNJNENRDWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJNENRDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
B1NQ1D2T
B1NQ1D2T
Noark Electric - Molded Case
B1NQ1D2T, Noark Electric, UL 489, type , 1PH, 1P, 120/240V, 2A, 10kA@240V, Bolt-On quick connect terminals load side, Thermal Magnetic, D trip curve, din rail mounted molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNR2NNADAX
MDN4083LEA0522NMNR2NNADAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR2NNADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
DSII-632-2400A-EO-DO-LIG
DSII-632-2400A-EO-DO-LIG
Cutler Hammer - Air
DSII-632-2400A-EO-DO-LIG, Cutler Hammer, DSII Series, type , 3200A frame size, electrically operated/Draw-Out, 3P, 3PH, 2400A, 600V, 65kA@480V, available with Digitrip RMS solid state trip unit, Solid State electronic, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNXNNNYMCX
MDN4083LEA0722NMNXNNNYMCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNXNNNYMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSB1G3L1I
SSB1G3L1I
General Electric - Insulated Case
SSB1G3L1I, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & modbus communication features and 450A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB1G2Z7N
SSB1G2Z7N
General Electric - Insulated Case
SSB1G2Z7N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PEAL2ATTN0060
PEAL2ATTN0060
General Electric - Molded Case
PEAL2ATTN0060, General Electric, GuardEon, type , 1PH, 2P in 3P construction, 600V, 60A, 150kA@480V, front connection/Feed-Thru, toggle mechanism, complete with LTM interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
MDN4083LEA0322NMNANENAMWX
MDN4083LEA0322NMNANENAMWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNANENAMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
LG3450S90
LG3450S90
Westinghouse - Molded Case
LG3450S90, Eaton, Westinghouse, Cutler Hammer, Series G, type , 3P, 3PH, 450A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, magnetic pickup range 500-2500, complete with right-pole mounted 48-60Vdc, 50/60Hz left side mount shunt trip, I - Instantaneous trip functions and line & load side lug terminals, Solid State electronic, engine generator molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNC2ENYCAX
MDN4083LEA0622NMNC2ENYCAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC2ENYCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNG2ENRNSX
MDN4083LEA0822NMNG2ENRNSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG2ENRNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHB4G6B9M
SHB4G6B9M
General Electric - Insulated Case
SHB4G6B9M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & modbus communication features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MPA41F10N3330
MPA41F10N3330
General Electric - Insulated Case
MPA41F10N3330, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 110/130V dc/ac motor operator, 110/130V dc/ac closing coil and 110/130V dc/ac shunt trip, 4P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNGNENRNAX
MDN4083LEA0322NMNGNENRNAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNGNENRNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & Ronis keylock, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNANYNYDCX
MDN4083LEA0722NMNANYNYDCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNANYNYDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price