- Home /
15 amp breaker
916,382 Results
Refine Results
In Stock
Subcategory
SORT BY

LV429850P
Schneider Electric - Molded Case
LV429850P, Schneider Electric, Compact NSX, type , 4P, 3PH, 100A, 690V, 50kA@415V, Plug-In, complete with NSX100N frame and 3 pole TM100D trip unit, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers
From Get Price

SEHF36400LSGES8A4
Schneider Electric - Insulated Case
SEHF36400LSGES8A4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 400A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SSB6G9E12
General Electric - Insulated Case
SSB6G9E12, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT & modbus communication features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

WLL1D312ME
Siemens - Insulated Case
WLL1D312ME, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 1200A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU745 programmer + WLGFA48, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 700A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

PDG33K0600E5ZN
Cutler Hammer - Molded Case
PDG33K0600E5ZN, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 600A, 50kA@480V, Bolt-On, no lug terminals, complete with PXR20 trip with ARMS LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

MDN4083LEA0122NMNJ4ECNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJ4ECNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0322NMNANENKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNANENKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MPA42F40V3340
General Electric - Insulated Case
MPA42F40V3340, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50L trip unit, 110/130V dc/ac motor operator, 110/130V dc/ac closing coil and 220/250V dc/ac shunt trip, 4P, 3PH, 4000A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price

HDA261504AFSHYP
Square D - Molded Case
HDA261504AFSHYP, Square D, PowerPact, type , 1PH, 2P, B & C phase connection, 150A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B low-level aux switch, 380/480 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,721.37

KLK24NC
Noark Electric - Part And Accessory
KLK24NC, Noark Electric, Ex9 Series, Locking Devices, handle lock, on position, suitable for use with M4 type UL 489 circuit breakers
From Get Price

REF3L010L
Miami Breaker - Molded Case
REF3L010L, Miami Breaker, REF Series, type , 3P, 3PH, 10A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, complete with I - Instantaneous protection only and line & load side lug terminals, low magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

HDY3B110B
Siemens - Molded Case
HDY3B110B, Siemens, VL Series, type , 3P, 3PH, 110A, 600V, 65kA@480V, high interrupting capacity, 40°C, Bolt-On, 100% rated, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price

MDN4083LEA0322NMNH4YNCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNH4YNCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0722NMNX2ENKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX2ENKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price

HGL26070ABBKSNYP
Square D - Molded Case
HGL26070ABBKSNYP, Square D, PowerPact, type , 2P, 1PH, 70A, 600V, 35kA@480V, high interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch and overcurrent trip switch, low-level, 12 VDC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,430.10

3VA6140-6HM41-2AA0
Siemens - Molded Case
3VA6140-6HM41-2AA0, Siemens, SENTRON 3VA, type , 100% rated, 3PH, 4P, 600V, 40A, high breaking capacity, 65kA@480V, Feed-Thru, fixed mounted, complete with ETU330 trip unit, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers
From Get Price

MDN4083LEA0422NMNH2YHNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH2YHNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0522NMNK4ECNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK4ECNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0522NMNRNYNLNCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNRNYNLNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0422NMNH4NCNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH4NCNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SED361400LSES2
Square D - Insulated Case
SED361400LSES2, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1400A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SED36400LSIGES7B4
Square D - Insulated Case
SED36400LSIGES7B4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 400A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

PDG32P0600D4ML
Cutler Hammer - Molded Case
PDG32P0600D4ML, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 600A, 100kA@480V, Bolt-On, load side lug terminals, complete with PXR20D ARMS trip with LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

MPA41F16V0047
General Electric - Insulated Case
MPA41F16V0047, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 220/250V dc/ac shunt trip and 380/440V ac undervoltage trip with delay, 4P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price