1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0722NMNF2NHNCWX
MDN4083LEA0722NMNF2NHNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNF2NHNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
PDG32K0600P3YJ
PDG32K0600P3YJ
Eaton - Molded Case
PDG32K0600P3YJ, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 600A, 50kA@480V, Feed-Thru, line & load side lug terminals, complete with PXR25 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with Modbus RTU, CAM link, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0122NNAH2YNNNAX
MDN4083LEA0122NNAH2YNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NNAH2YNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, electrically operated with 110-120Vac motor operator and 110-127Vac/dc spring release device (SRD), factory installed 48Vdc UVR, 2A/2B auxiliary switch, mechanical trip indicator & OTS switch, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNF2YNNMPX
MDN4083LEA0122NMNF2YNNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF2YNNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
K808LI
K808LI
General Electric - Trip Units And Programmers
K808LI, General Electric, MicroVersaTrip Plus, trip units and programmers, 800A current sensor rating, Solid State electronic, LI - Long-Time and Instantaneous trip functions, suitable for use with 800A frame WavePro WPS,WPH,WPF,WPX low voltage power circuit breakers
From Get Price
Limited Stock
SKHH3610L4T6
SKHH3610L4T6
General Electric - Molded Case
SKHH3610L4T6 General Electric Spectra Series, type , 3P, 3PH, 1000A, 600V, 50kA@480V, extra high interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIG, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault and ZSI, zone selective interlocking trip functions and advanced metering, modbus & waveform capture communication features, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNE2NHNCWX
MDN4083LEA0522NMNE2NHNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE2NHNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNENNNADSX
MDN4083LEA0422NMNENNNADSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNENNNADSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PDG32M0250E4NL
PDG32M0250E4NL
Cutler Hammer - Molded Case
PDG32M0250E4NL, Cutler Hammer, Eaton, Power Defense, type , 1PH, 2P, 600V, 250A, 65kA@480V, Bolt-On, load side lug terminals, complete with PXR20 trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions , Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0722NMNENYNAMSX
MDN4083LEA0722NMNENYNAMSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNENYNAMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNR4ENYMSX
MDN4083LEA0622NMNR4ENYMSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR4ENYMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
LGX340038GVH09
LGX340038GVH09
Cutler Hammer - Molded Case
LGX340038GVH09, Cutler Hammer, Series G, type , 3P, 3PH, 400A, 600V, 200kA@480V, current limiting, for Naval applications 50°C, not UL listed, Feed-Thru, complete with interchangeable trip, ALSI - Arcflash Reduction, Long-Time, Short-Time and Instantaneous trip functions with arcflash reduction maintenance system and line & load side lug terminals, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNX2ENCDAX
MDN4083LEA0322NMNX2ENCDAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNX2ENCDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNXNYNYMAX
MDN4083LEA0622NMNXNYNYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNXNYNYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
WLL2F312GN
WLL2F312GN
Siemens - Insulated Case
WLL2F312GN, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 1200A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU748 programmer + WLLCD48 LCD display + WLGFA48 ground fault module, LSGA - Long-Time, Short-Time and Ground Fault Alarm trip functions and 400A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SHB4G668P
SHB4G668P
General Electric - Insulated Case
SHB4G668P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communcation & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNCNYNLDWX
MDN4083LEA0322NMNCNYNLDWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNCNYNLDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNG2YNLMWX
MDN4083LEA0222NMNG2YNLMWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG2YNLMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNH2NNRMCX
MDN4083LEA0722NMNH2NNRMCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH2NNRMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MPA41F0803130
MPA41F0803130
General Electric - Insulated Case
MPA41F0803130, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 110/130V dc/ac motor operator, 24/30V dc closing coil and 110/130V dc/ac shunt trip, 4P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNCNYNNCWX
MDN4083LEA0622NMNCNYNNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNCNYNNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SSD1G2X1E
SSD1G2X1E
General Electric - Insulated Case
SSD1G2X1E, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering features and 250A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNG2YNKDAX
MDN4083LEA0322NMNG2YNKDAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG2YNKDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNH2NNKMCX
MDN4083LEA0422NMNH2NNKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH2NNKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price