Limited Stock
EEFD240070SB2
EEFD240070SB2
Cutler Hammer - Mounting Hardware
EEFD240070SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 70A, AC phase connection, 480V max, Copper, Single Branch mounting style, suitable for use with EHD,FDB,FD,HFD,FDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
THPMM5606
THPMM5606
General Electric - Insulated Case
THPMM5606, General Electric, Power Break I, type , 3P, 3PH, 600V, 600A current sensor rating, 1600A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, with non-interchangeable MagneTrip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNR4ENHDSX
MDN4083LEA0522NMNR4ENHDSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR4ENHDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNX4ENYMPX
MDN4083LEA0422NMNX4ENYMPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNX4ENYMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNK2NNLCWX
MDN4083LEA0622NMNK2NNLCWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK2NNLCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
457D446G03
457D446G03
Eaton - Trip Units And Programmers
457D446G03, Eaton, Naval, Thermal Magnetic trip units and programmers, type -A250, 2P, 125A, 500Vac, 910-1560 instantaneous trip setting, LI - Long-Time and Instantaneous trip functions, suitable for use with AQB-A250,AQB-A250-125NH circuit breakers for naval shipboard use
From Get Price
Limited Stock
MDN4083LEA0422NMNG4ENHDCX
MDN4083LEA0422NMNG4ENHDCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG4ENHDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHB4G6M3W
SHB4G6M3W
General Electric - Insulated Case
SHB4G6M3W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communcation & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF2G5E1P
SSF2G5E1P
General Electric - Insulated Case
SSF2G5E1P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT & modbus communication features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0622NMNENNCNMSX
MDN4083LEA0622NMNENNCNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNENNCNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHB1G354N
SHB1G354N
General Electric - Insulated Case
SHB1G354N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0622NMNH4ENCDWX
MDN4083LEA0622NMNH4ENCDWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNH4ENCDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
EGB4030FFGH08
EGB4030FFGH08
Cutler Hammer - Molded Case
EGB4030FFGH08, Cutler Hammer, Series G, type , 4P, 3PH, 30A, 480V, 18kA@480V, standard interrupting capacity, UL listed for Marine applications 40°C, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SHD6G9N91
SHD6G9N91
General Electric - Insulated Case
SHD6G9N91, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communication & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
E2B-A16-4P-400A-BO-MO-LSIG
E2B-A16-4P-400A-BO-MO-LSIG
ABB - Insulated Case
E2B-A16-4P-400A-BO-MO-LSIG, ABB, EMax, type , 4P, 3PH, 1600A frame, 400A rating plug, 600V, 42kA@480V, fixed/Bolt-On, manually operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
E4L-A36-4P-2000A-DO-MO-LSIG
E4L-A36-4P-2000A-DO-MO-LSIG
ABB - Insulated Case
E4L-A36-4P-2000A-DO-MO-LSIG, ABB, EMax, type , 4P, 3PH, 3600A frame, 2000A rating plug, 600V, 125kA@480V, Draw-Out, manually operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
PDG32M0125E5RK
PDG32M0125E5RK
Cutler Hammer - Molded Case
PDG32M0125E5RK, Cutler Hammer, Eaton, Power Defense, type , 1PH, 2P, 600V, 125A, 65kA@480V, Bolt-On, line side lug terminals, complete with PXR20 trip with ARMS LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
JGS4150FAGH08
JGS4150FAGH08
Cutler Hammer - Molded Case
JGS4150FAGH08, Cutler Hammer, Series G, Type , 4P, 3PH, 150A, 600V, 35kA@480V, standard interrupting capacity, UL listed for Marine applications 40°C, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
SHD4G7W71
SHD4G7W71
General Electric - Insulated Case
SHD4G7W71, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNA2ENKDAX
MDN4083LEA0822NMNA2ENKDAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA2ENKDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPD42C40
MPD42C40
General Electric - Cubicles (Cradles)
MPD42C40, General Electric, M-PACT, type , cubicles (cradles), basic cassette with flat copper terminals rear connected, integral racking handle, safety shutters and lockable safety features, suitable for use with 4000A, 4 pole MPD frame size 2 air circuit breakers
From Get Price
Limited Stock
WLL2D330AU
WLL2D330AU
Siemens - Insulated Case
WLL2D330AU, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 3000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU755 programmer + WLGFM76 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNJNENNDWX
MDN4083LEA0522NMNJNENNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJNENNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals and latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, ships in drawout narrow breakers with shutters, pre-wired
From Get Price
Limited Stock
MPA31F0802255
MPA31F0802255
General Electric - Insulated Case
MPA31F0802255, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 48V dc motor operator, 48V dc closing coil, 380/400V ac shunt trip and 30/48V dc undervoltage trip with delay, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers