1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0822NMNG4YCNNAX
MDN4083LEA0822NMNG4YCNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG4YCNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
TQD24125
TQD24125
General Electric - Molded Case
TQD24125, General Electric, Q-Line, type , 2P, 1PH, 415V, 125A, 10kA@220V, UL listed, standard interrupting capacity, Bolt-On, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
SSB3G614R
SSB3G614R
General Electric - Insulated Case
SSB3G614R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
1228C79G03
1228C79G03
Cutler Hammer - Rating Plug
1228C79G03, Cutler Hammer, Current Limit-R, type , rating plug element, rated for 250A, suitable for use with 400A - HLCLM mining service molded case circuit breaker frame types, for use with Current Limit-R thermal magnetic trip units & circuit breakers
From Get Price
Limited Stock
MPA31F0804124
MPA31F0804124
General Electric - Insulated Case
MPA31F0804124, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 220/250V dc/ac motor operator, 24/30V dc closing coil, 48V dc shunt trip and 380/440V ac undervoltage trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNC2ENNCWX
MDN4083LEA0122NMNC2ENNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2ENNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, with shutters, pre-wired
From Get Price
Limited Stock
SSF2G4X2N
SSF2G4X2N
General Electric - Insulated Case
SSF2G4X2N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNJ4YNRMSX
MDN4083LEA0822NMNJ4YNRMSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJ4YNRMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSB2G4Y3H
SSB2G4Y3H
General Electric - Insulated Case
SSB2G4Y3H, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication, relays & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNX2YNNCWX
MDN4083LEA0822NMNX2YNNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNX2YNNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNN4NNLNCX
MDN4083LEA0422NMNN4NNLNCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN4NNLNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNN4NNNMWX
MDN4083LEA0122NMNN4NNNMWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN4NNNMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNR2ENYDWX
MDN4083LEA0722NMNR2ENYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR2ENYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
GNS3125T32WP07
GNS3125T32WP07
Cutler Hammer - Molded Case
GNS3125T32WP07, Cutler Hammer, Series G, type , 1250A frame, 3P, 3PH, 600V, 50kA@480V, standard interrupting capacity, Bolt-On, complete with Digitrip RMS 310 trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, 600A fixed rating plug, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SSB1G3C9F
SSB1G3C9F
General Electric - Insulated Case
SSB1G3C9F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & modbus communication features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MPA41F10W4400
MPA41F10W4400
General Electric - Insulated Case
MPA41F10W4400, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 220/250V dc/ac motor operator and 220/250V dc/ac closing coil, 4P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
E4V-A36-4P-1200A-BO-EO-LI
E4V-A36-4P-1200A-BO-EO-LI
ABB - Insulated Case
E4V-A36-4P-1200A-BO-EO-LI, ABB, EMax, type , 4P, 3PH, 3600A frame, 1200A rating plug, 600V, 100kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0522NMNA4NNACCX
MDN4083LEA0522NMNA4NNACCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA4NNACCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MPA31F12N2140
MPA31F12N2140
General Electric - Insulated Case
MPA31F12N2140, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 48V dc motor operator, 24/30V dc closing coil, 220/250V dc/ac shunt trip, 3P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNFNNNCNSX
MDN4083LEA0322NMNFNNNCNSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNFNNNCNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
Q235H00S07
Q235H00S07
Siemens - Molded Case
Q235H00S07 Siemens Q Series, type , 2P, 1PH, 35A, 120/240V, 22kA@240V, high interrupting capacity, with factory installed 24V shunt trip, Plug-In, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
SSD1G3Q9L
SSD1G3Q9L
General Electric - Insulated Case
SSD1G3Q9L, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 700A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNK2YNRDWX
MDN4083LEA0822NMNK2YNRDWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNK2YNRDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
WLS2F308FC
WLS2F308FC
Siemens - Insulated Case
WLS2F308FC, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 800A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer with LSI - Long-Time, Short-Time and Instantaneous trip functions with 350A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price