1. Home / 
  2. square d breaker

SORT BY
Limited Stock
SHB1G2W6D
SHB1G2W6D
General Electric - Insulated Case
SHB1G2W6D, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, RELT, modbus communication, relays & ZSI features and 225A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF4G611T
SSF4G611T
General Electric - Insulated Case
SSF4G611T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
3VA9471-0WK40
3VA9471-0WK40
Siemens - Part And Accessory
3VA9471-0WK40, Siemens, SENTRON 3VA, Connection Devices, rear insulating plate offset, suitable for use with 4-pole 3VA63,3VA64 400A/600A frame circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNC4YNLNAX
MDN4083LEA0522NMNC4YNLNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNC4YNLNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNN4YNCMAX
MDN4083LEA0322NMNN4YNCMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN4YNCMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNE2EHNNSX
MDN4083LEA0622NMNE2EHNNSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNE2EHNNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNENYNLNAX
MDN4083LEA0522NMNENYNLNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNENYNLNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch, & Castell key interlock, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNJ2YNKCWX
MDN4083LEA0522NMNJ2YNKCWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ2YNKCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNR2NNKNWX
MDN4083LEA0422NMNR2NNKNWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR2NNKNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MPA31F10N2050
MPA31F10N2050
General Electric - Insulated Case
MPA31F10N2050, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 48V dc motor operator and 380/400V ac shunt trip, 3P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
140G-JTC3-C30
140G-JTC3-C30
Allen-Bradley - Trip Units And Programmers
140G-JTC3-C30, Allen-Bradley, Bulletin 140G, trip units and programmers, type , 3P, 30A, 600V, LI - Long-Time and Instantaneous trip functions, suitable for use with 140G-J 250A Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
2607D97G44
2607D97G44
Westinghouse - Motor Operator
2607D97G44, Westinghouse, TRI-PAC, motor operator, 125Vdc, UL listed, suitable for use with LA frame molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNC2NNYMCX
MDN4083LEA0122NMNC2NNYMCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2NNYMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
WHM2R12
WHM2R12
Cutler Hammer - Part And Accessory
WHM2R12, Cutler Hammer, Series C, part and accessory, IEC rated Operating Handles, IEC IP65, rotary through-the-door handle mechanism, includes handle, mechanism, shaft & support brace/bracket, 12-inch shaft length, suitable for use with JDB,JD,HJD,JDC molded case circuit breaker frames
From Get Price
Limited Stock
B330LSHMR
B330LSHMR
General Electric - Trip Units And Programmers
B330LSHMR, General Electric, MicroVersaTrip PM, type , replacement trip units and programmers, 3000A current sensor rating, Solid State electronic, LSI - Long-Time, Short-Time and Instantaneous, high range instantaneous, trip functions, metering & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNNNEMCCCX
MDN4083LEA0122NMNNNEMCCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNEMCCCX, Cutler Hammer, Magnum DS, type , drawout mounted, factory installed padlock pushbutton cover on narrow metal frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, latch check switch for external wiring, upper terminal voltage connection, Castell keylock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, without shutters and unwired
From Get Price
Limited Stock
WLL2D312AP
WLL2D312AP
Siemens - Insulated Case
WLL2D312AP, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 1200A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU748 programmer+ WLGFM48 ground fault module, LSG - Long-Time, Short-Time and Ground Fault trip functions and 200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNN4NNNNSX
MDN4083LEA0722NMNN4NNNNSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4NNNNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
THS25316E1
THS25316E1
General Electric - Insulated Case
THS25316E1, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 3P, 3PH, 600V, 1600A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and standard dual magnetic trip unit, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNE2YNCDWX
MDN4083LEA0522NMNE2YNCDWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE2YNCDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNC4NNHCCX
MDN4083LEA0122NMNC4NNHCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC4NNHCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PDF44G0800E3CN
PDF44G0800E3CN
Cutler Hammer - Molded Case
PDF44G0800E3CN, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 800A, 35kA@480V, Bolt-On, no lug terminals, complete with PXR20 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, relays and CAM, Solid State electronic, molded case circuit breakers; globally rated, 100% UL rated
From Get Price
Limited Stock
MDN4083LEA0522NMNKNYMNDWX
MDN4083LEA0522NMNKNYMNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNKNYMNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SSF3G6Q2P
SSF3G6Q2P
General Electric - Insulated Case
SSF3G6Q2P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price