Limited Stock
MPA41F25W0150
MPA41F25W0150
General Electric - Insulated Case
MPA41F25W0150, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc closing coil and 380/400V ac shunt trip, 4P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNR4ENRNAX
MDN4083LEA0122NMNR4ENRNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNR4ENRNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
E4H-A36-3P-2500A-BO-EO-LSI
E4H-A36-3P-2500A-BO-EO-LSI
ABB - Insulated Case
E4H-A36-3P-2500A-BO-EO-LSI, ABB, EMax, type , 3P, 3PH, 3600A frame, 2500A rating plug, 600V, 85kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
TS3N025TW-2
TS3N025TW-2
ABB - Molded Case
TS3N025TW-2, ABB, SACE Tmax, type , 2P, 1PH, 25A, 480V, 25kA@480V, 35kA@415V, Bolt-On, suitable for reverse feed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
F63T080
F63T080
ITE - Trip Units And Programmers
F63T080, ITE, Siemens, F Series, trip units and programmers, 3P, 600V, 80A, Thermal Magnetic, LI - Long-Time and Instantaneous functions, suitable for ITE F6 frame breakers
From Get Price
Limited Stock
SHF1G3W8F
SHF1G3W8F
General Electric - Insulated Case
SHF1G3W8F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNG2ENYCWX
MDN4083LEA0722NMNG2ENYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNG2ENYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNH2YHNCCX
MDN4083LEA0822NMNH2YHNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH2YHNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNCNENKNWX
MDN4083LEA0722NMNCNENKNWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNCNENKNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNE4ENKDWX
MDN4083LEA0622NMNE4ENKDWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNE4ENKDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNC2YNYDWX
MDN4083LEA0122NMNC2YNYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2YNYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNG2ENHMWX
MDN4083LEA0222NMNG2ENHMWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG2ENHMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNF2EHNNAX
MDN4083LEA0722NMNF2EHNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNF2EHNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNK4NNRCAX
MDN4083LEA0422NMNK4NNRCAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK4NNRCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNG4NNNMSX
MDN4083LEA0122NMNG4NNNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNG4NNNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
GLC3500AAM
GLC3500AAM
Cutler Hammer - Molded Case
GLC3500AAM, Cutler Hammer, Series G, type , 3P, 3PH, 500A, 600V, 100kA@480V, very high interrupting capacity, 40°C, Bolt-On, complete with interchangeable trip unit, metric end caps, adjustable Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNRNNNHDPX
MDN4083LEA0722NMNRNNNHDPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNRNNNHDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MPA42F32V1110
MPA42F32V1110
General Electric - Insulated Case
MPA42F32V1110, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50L trip unit, 24/30V dc motor operator, 24/30V dc closing coil and 24/30V dc shunt trip, 4P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNFNENNCSX
MDN4083LEA0722NMNFNENNCSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNFNENNCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals and latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, with shutters, unwired
From Get Price
Limited Stock
WLL3F340PK
WLL3F340PK
Siemens - Insulated Case
WLL3F340PK, Siemens, WL Series, type , frame size III, fixed mount, 3P, 3PH, 4000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU748 programmer + WLLCD48 LCD display, LS - Long-Time and Short-Time trip functions and 1000A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNA2YNCNSX
MDN4083LEA0722NMNA2YNCNSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNA2YNCNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNK4YNAMPX
MDN4083LEA0322NMNK4YNAMPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK4YNAMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
M3N250T3L
M3N250T3L
Noark Electric - Molded Case
M3N250T3L, Noark Electric, Ex9 Series, type , 3PH, 3P, 600V, 250A, 100kA@240V, complete with LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SSD5G8R3U
SSD5G8R3U
General Electric - Insulated Case
SSD5G8R3U, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems