


- Home /
square d breaker
961,107 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0222NMNF2YNCCCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNF2YNCCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

SSD4G613U
General Electric - Insulated Case
SSD4G613U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0822NMNG4NHNCSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG4NHNCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0622NMNR2EHNDAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR2EHNDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

WLL2D325AL
Siemens - Insulated Case
WLL2D325AL, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 2500A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU748 programmer + WLGFA48 ground fault module, LSGA - Long-Time, Short-Time and Ground Fault Alarm trip functions and 200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

MDN4083LEA0522NMNHNNNCNWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNHNNNCNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0122NMNRNENRCWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNRNENRCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0222NMNR2ENKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNR2ENKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

B325LSHGZ2P
General Electric - Trip Units And Programmers
B325LSHGZ2P, General Electric, MicroVersaTrip PM, type , trip units and programmers, 2500A current sensor rating, Solid State electronic, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, high-range instantaneous, trip functions, short-time selective interlock, protective relays & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price

MDN4083LEA0222NMNK2YNHDAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK2YNHDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0522NMNHNENHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNHNENHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price

SKTT3408L4S6
General Electric - Molded Case
SKTT3408L4S6, General Electric, Spectra Series, type , 3P, 3PH, 800A, 480V, 65kA@480V, standard interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault + ZSI trip functions with extended instantaneous, advanced metering + modbus features + waveform capture, Solid State with neutral protection, molded case circuit breakers
From Get Price

SSB1G3M8J
General Electric - Insulated Case
SSB1G3M8J, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communication & ZSI features and 500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0222NMNGNYNHDCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNGNYNHDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0722NMNGNNNNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNGNNNNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

SSF4G4Z8K
General Electric - Insulated Case
SSF4G4Z8K, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SHD4G7M41
General Electric - Insulated Case
SHD4G7M41, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT, modbus communication & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

E3X-A08-4P-400A-BO-MO-LSIG
ABB - Insulated Case
E3X-A08-4P-400A-BO-MO-LSIG, ABB, EMax, type , 4P, 3PH, 800A frame, 400A rating plug, 600V, 200kA@480V, fixed mount/Bolt-On, manually operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price

MPA31F0803443
General Electric - Insulated Case
MPA31F0803443, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 110/130V dc/ac motor operator, 220/250V dc/ac closing coil, 220/250V dc/ac shunt trip and 220/250V ac undervoltage trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price

M2N150T2
Noark Electric - Molded Case
M2N150T2, Noark Electric, Ex9 Series, type , 1PH, 2P, 600V, 150A, 100kA@240V, complete with LI - Long-Time and Instantaneous trip functions and bus bar connection, Thermal Magnetic, molded case circuit breakers
From Get Price

MDN4083LEA0822NMNC2NNRCSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2NNRCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0222NMNCNENACAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNCNENACAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0622NMNXNNNKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNXNNNKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price

SSB4G6B9P
General Electric - Insulated Case
SSB4G6B9P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price