


- Home /
15 amp breaker
916,382 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0422NMNK4NCNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK4NCNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

HDA36100AEBHSK
Square D - Molded Case
HDA36100AEBHSK, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 100A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch low-level, 24 VAC shunt trip, molded case circuit breakers
From $1,995.00

SEHF363200LSES8C8
Schneider Electric - Insulated Case
SEHF363200LSES8C8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SED362500ES6
Square D - Insulated Case
SED362500ES6, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

HDL26150AFBCUR
Square D - Molded Case
HDL26150AFBCUR, Square D, PowerPact, type , 2P, 1PH, 150A, 600V, 18kA@480V, standard interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 2A/2B low-level aux switch, alarm switch, 125 VDC under voltage release (UVR), molded case circuit breakers
From $1,683.97

TPSS6616BDG
General Electric - Insulated Case
TPSS6616BDG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 1600A, inverted construction, with ground-fault protection, 1-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

PDG34F0250D4WN
Cutler Hammer - Molded Case
PDG34F0250D4WN, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 250A, 25kA@480V, Bolt-On, no lug terminals, complete with PXR20D trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

SEHD361600LIES3E4
Schneider Electric - Insulated Case
SEHD361600LIES3E4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1600A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SED36200LST3
Schneider Electric - Insulated Case
SED36200LST3, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, complete with 48VDC shunt trip & 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0222NMNN4YCNCPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNN4YCNCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

CMHFE46125LI
Merlin Gerin - Insulated Case
CMHFE46125LI, Schneider Electric, Merlin Gerin, insulated case circuit breaker, Compact CM, type , Bolt-On, 4P, 3PH, 1250A, 600V, 85kA@480V, Solid State electronic, STCM1 trip unit, LI - Long-Time and Instantaneous functions
From Get Price

MDN4083LEA0422NMNE2NHNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNE2NHNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

WLL2D316D
Siemens - Insulated Case
WLL2D316D, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 1600A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state programmer with LSI - Long-Time, Short-Time and Instantaneous trip functions and 300A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

EEKD210400SB2
Cutler Hammer - Mounting Hardware
EEKD210400SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 400A, AC phase connection, 120V max, Copper, Single Branch mounting style, suitable for use with KD,HKD,KDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

MDN4083LEA0322NMNCNNCNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNCNNCNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

SEF36400LSIES5F4
Schneider Electric - Insulated Case
SEF36400LSIES5F4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

25829
Merlin Gerin - Molded Case
25829, Square D, Schneider Electric, Merlin Gerin, Multi9, type , 3P, 3PH, 6A, 440V, 6kA@415V, C curve, standard interrupting capacity, Feed-Thru, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, miniature molded case circuit breakers
From Get Price

PJL26000S80BC
Schneider Electric - Molded Case
PJL26000S80BC, Square D, Schneider Electric, PowerPact, type , 2P, 1PH, 800A, 600V, 65kA@480V, UL listed, high interrupting capacity, Feed-Thru, complete with 1A/1B alarm switch, NA - No Overcurrent Protection, Non-Automatic switch, line & load side lug terminals, molded case circuit breakers
From Get Price

SED36600LIB4
Schneider Electric - Insulated Case
SED36600LIB4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 600A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0422NMNF2YNRNPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF2YNRNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

HJA36060AEBESLYP
Square D - Molded Case
HJA36060AEBESLYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 60A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, 48 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,962.87

SEHD361600LSIGES8E4
Schneider Electric - Insulated Case
SEHD361600LSIGES8E4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1600A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEF361000ES6E4
Schneider Electric - Insulated Case
SEF361000ES6E4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1000A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete
From Get Price

PDG34M0125B2NJ
Cutler Hammer - Molded Case
PDG34M0125B2NJ, Cutler Hammer, Eaton, Power Defense, type , 3PH, 4P, 600V, 125A, 65kA@480V, Feed-Thru, line & load side lug terminals, complete with PXR10 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price