Limited Stock
MDN4083LEA0822NMNC2NNRCWX
MDN4083LEA0822NMNC2NNRCWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2NNRCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
EE3L090L
EE3L090L
ITE - Molded Case
EE3L090L, ITE, Siemens, EE Series, type , 3P, 3PH, 90A, 240V, 10kA@240V, standard interrupting capacity, Feed-Thru, complete with I - Instantaneous protection only and line & load side lug terminals, low magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers
From Get Price
Limited Stock
MPA41F16V1110
MPA41F16V1110
General Electric - Insulated Case
MPA41F16V1110, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 24/30V dc motor operator, 24/30V dc closing coil and 24/30V dc shunt trip, 4P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SNT1RB03
SNT1RB03
Cutler Hammer - Shunt Trip
SNT1RB03, Cutler Hammer, Series C, factory mounted shunt trip, 24 - 24V, right or neutral pole mounted, rear side connected, pigtail style leads, suitable for use with Series C FDB,FD,HFD,HFDDC,FDC,FG,E2F,E2FM and F-frame HMCP molded case circuit breaker frames
From Get Price
Limited Stock
SGHC3606L3P6
SGHC3606L3P6
General Electric - Molded Case
SGHC3606L3P6 General Electric Spectra Series, type , 3P, 3PH, 600A, 600V, 35kA@480V, standard interrupting capacity, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSI, LSI - Long-Time, Short-Time and Instantaneous and ZSI, zone selective interlocking & RELT, reduced energy let-through trip functions and advanced metering, modbus & waveform capture communication features, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNF2YNYNAX
MDN4083LEA0522NMNF2YNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNF2YNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
PDG32F0250E3RJ
PDG32F0250E3RJ
Cutler Hammer - Molded Case
PDG32F0250E3RJ, Cutler Hammer, Eaton, Power Defense, type , 1PH, 2P, 600V, 250A, 25kA@480V, Feed-Thru, line & load side lug terminals, complete with PXR20 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
SSF3G6E3T
SSF3G6E3T
General Electric - Insulated Case
SSF3G6E3T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT & modbus communication features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0422NMNK2NNYDWX
MDN4083LEA0422NMNK2NNYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK2NNYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
DSLII-632-3000A-MO-DO-LSIG
DSLII-632-3000A-MO-DO-LSIG
Cutler Hammer - Air
DSLII-632-3000A-MO-DO-LSIG, Cutler Hammer, DSLII Series, type , 3200A frame size, manually operated/Draw-Out, 3P, 3PH, 3000A, 600V, 200kA@480V, available with Digitrip RMS solid state trip unit, Solid State electronic, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNH4YNYMCX
MDN4083LEA0322NMNH4YNYMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNH4YNYMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
B204LIGDPMR
B204LIGDPMR
General Electric - Trip Units And Programmers
B204LIGDPMR, General Electric, MicroVersaTrip PM, type , replacement trip units and programmers, 400A current sensor rating, Solid State electronic, LIG - Long-Time, Instantaneous and Ground Fault, ground fault defeatable, trip functions, protective relays, metering & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price
Limited Stock
MPA41F25N4320
MPA41F25N4320
General Electric - Insulated Case
MPA41F25N4320, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 220/250V dc/ac motor operator, 110/130V dc/ac closing coil and 48V dc shunt trip, 4P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
PDF43K0800P2WK
PDF43K0800P2WK
Cutler Hammer - Molded Case
PDF43K0800P2WK, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 800A, 50kA@480V, Bolt-On, line side lug terminals, complete with PXR25 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions, relays, modbus and ZSI, Solid State electronic, molded case circuit breakers; globally rated, 100% UL rated
From Get Price
Limited Stock
MDN4083LEA0622NMNX4NNYNPX
MDN4083LEA0622NMNX4NNYNPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX4NNYNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNRNYNRDSX
MDN4083LEA0222NMNRNYNRDSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNRNYNRDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNN2NNKCPX
MDN4083LEA0322NMNN2NNKCPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN2NNKCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHD4G4C7P
SHD4G4C7P
General Electric - Insulated Case
SHD4G4C7P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering & modbus communication features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB1G2H1B
SSB1G2H1B
General Electric - Insulated Case
SSB1G2H1B, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communication and relays features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF5G8W62
SSF5G8W62
General Electric - Insulated Case
SSF5G8W62, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, RELT, modbus communication, relays & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
609906-T007
609906-T007
ABB - Trip Units And Programmers
609906-T007, ABB, BBC, ITE, K-Line, Power Shield Assembly Trip Device Type SS-7, 4000A, Instantaneous, No Target, suitable for K-4000S
From Get Price
Limited Stock
SSF3G6C4M
SSF3G6C4M
General Electric - Insulated Case
SSF3G6C4M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & modbus communication features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG24G0225E2CJ
PDG24G0225E2CJ
Eaton - Molded Case
PDG24G0225E2CJ, Cutler Hammer, Eaton, Power Defense, type , 3PH, 4P, 600V, 225A, 35kA@480V, Feed-Thru, line & load side lug terminals, complete with Xpert Release PXR20 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions, relays and CAM, Solid State electronic, molded case circuit breakers; globally rated
From Get Price
Limited Stock
MPA31F2003310
MPA31F2003310
General Electric - Insulated Case
MPA31F2003310, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 110/130V dc/ac motor operator, 110/130V dc/ac closing coil and 24/30V dc shunt trip, 3P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price