1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0822NMNK4NNKCSX
MDN4083LEA0822NMNK4NNKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNK4NNKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNK2ENLCCX
MDN4083LEA0522NMNK2ENLCCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK2ENLCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNC4YNKMCX
MDN4083LEA0422NMNC4YNKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNC4YNKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
In Stock
HJA36070ABBHUKYP
HJA36070ABBHUKYP
Square D - Molded Case
HJA36070ABBHUKYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 70A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch low-level, 24 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,031.12
Limited Stock
SEF36250LSMR
SEF36250LSMR
Square D - Insulated Case
SEF36250LSMR, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 250A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, motor ready for electrical operation, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
WLH1D308NH
WLH1D308NH
Siemens - Insulated Case
WLH1D308NH, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 800A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU745 programmer + WLLCD48 LCD display + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 800A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122RPRR2NNNNAX
MDN4083LEA0122RPRR2NNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122RPRR2NNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 208-250Vdc shunt trip (ST), 208-240Vac UVR, 2A/2B auxiliary switch & mechanical trip indicator, electrically operated with factory installed 220-240Vac motor operator & 208-250Vac spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price
In Stock
HDA260702AABKUP
HDA260702AABKUP
Square D - Molded Case
HDA260702AABKUP, Square D, PowerPact, type , 1PH, 2P, A & C phase connection, 70A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B aux switch, alarm switch and overcurrent trip switch, low-level, 48 VDC under voltage release (UVR), molded case circuit breakers
From $1,740.90
Limited Stock
PDG33FH400E2XJ
PDG33FH400E2XJ
Eaton - Molded Case
PDG33FH400E2XJ, Eaton, Cutler Hammer, Power Defense, type , 3PH, 3P, 600V, 400A, High Override, 25kA@480V, Feed-Thru, line & load side lug terminals, complete with PXR20 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions with CAM link, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
PDG13M0125KNSN
PDG13M0125KNSN
Eaton - Molded Case
PDG13M0125KNSN, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 125A, 65kA@480V, Bolt-On, no lug terminals, Non-Automatic, molded case switch, NA - No Overcurrent Protection; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
PGD36025U41ABC
PGD36025U41ABC
Square D - Molded Case
PGD36025U41ABC, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 250A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with 1A/1B alarm switch, micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNX2NHNNWX
MDN4083LEA0522NMNX2NHNNWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNX2NHNNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SEHF361800ES4E4
SEHF361800ES4E4
Square D - Insulated Case
SEHF361800ES4E4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1800A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNRNYNYNSX
MDN4083LEA0622NMNRNYNYNSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNRNYNYNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SV-9968.179
SV-9968.179
Rittal - Part And Accessory
SV-9968.179, Rittal part and accessory
From Get Price
Limited Stock
MDN4083LEA0822NMNA4YNCDSX
MDN4083LEA0822NMNA4YNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA4YNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
QJ2200
QJ2200
Murray Corporation - Molded Case
QJ2200, Murray Corporation, QJ Series, type , 2P, 1PH, 200A, 240V, 10kA@240V, standard interrupting capacity, Bolt-On, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SED364000LIGET3
SED364000LIGET3
Schneider Electric - Insulated Case
SED364000LIGET3, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 4000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
LGN34600WU44X
LGN34600WU44X
Square D - Molded Case
LGN34600WU44X, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 600A, 480V, 35kA@480V, high interrupting capacity, UL listed, Plug-In, suitable for reverse connection, complete with non-interchangeable mission critical ammeter 6.3A-W trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
CKS2300
CKS2300
Challenger - Molded Case
CKS2300, Challenger, CKS Series, type , 2P, 1PH, 300A, 600V, 35kA@480V, standard interrupting, 40°C, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
AKRT-6S-50-EO-BI-LI
AKRT-6S-50-EO-BI-LI
General Electric - Air
AKRT-6S-50-EO-BI-LI, General Electric, Electrically Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAV}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
MDN4083LEA0322NMNGNNNYCSX
MDN4083LEA0322NMNGNNNYCSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNGNNNYCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MPA42F32V0047
MPA42F32V0047
General Electric - Insulated Case
MPA42F32V0047, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50L trip unit, 220/250V dc/ac shunt trip and 380/440V ac undervoltage trip with delay, 4P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNX2YNLDAX
MDN4083LEA0122NMNX2YNLDAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNX2YNLDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price