Limited Stock
MDN4083LEA0722NMNJ2ENYDPX
MDN4083LEA0722NMNJ2ENYDPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ2ENYDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSD4G684W
SSD4G684W
General Electric - Insulated Case
SSD4G684W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communcation, relays & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PKF36025U41BRE10
PKF36025U41BRE10
Schneider Electric - Molded Case
PKF36025U41BRE10, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 250A, 600V, 50kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with door mounted standard black handle, micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
In Stock
HDA36035AESV
HDA36035AESV
Square D - Molded Case
HDA36035AESV, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 35A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B low-level aux switch, 60 VDC shunt trip, molded case circuit breakers
From $1,774.50
In Stock
HJA260304BCSHYP
HJA260304BCSHYP
Square D - Molded Case
HJA260304BCSHYP, Square D, PowerPact, type , 1PH, 2P, B & C phase connection, 30A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with alarm switch, 380/480 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,887.27
Limited Stock
MDN4083LEA0822NMNC2NNCMWX
MDN4083LEA0822NMNC2NNCMWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2NNCMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SEHF361600ES2D4
SEHF361600ES2D4
Square D - Insulated Case
SEHF361600ES2D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1600A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNC2EHNMAX
MDN4083LEA0822NMNC2EHNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2EHNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNG4ECKCWX
MDN4083LEA0522NMNG4ECKCWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG4ECKCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, 4A/4B auxiliary switch, latch check switch for external wiring, load side lug terminals & Kirk keylock Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SSB1G136A
SSB1G136A
General Electric - Insulated Case
SSB1G136A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, modbus communication & ZSI features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHF361000ES3D5
SEHF361000ES3D5
Square D - Insulated Case
SEHF361000ES3D5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
In Stock
HRA36100U31XAFBEUPYP
HRA36100U31XAFBEUPYP
Square D - Molded Case
HRA36100U31XAFBEUPYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 100A, 600V, 200kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2 non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch and overcurrent trip switch, 48 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $3,929.12
Limited Stock
PEBE4ATGR0125
PEBE4ATGR0125
General Electric - Molded Case
PEBE4ATGR0125, General Electric, GuardEon, type , 3PH, 4P, 600V, 125A, 35kA@480V, factory set to 100% neutral protection, 100% rated, front connection/Feed-Thru, toggle mechanism, complete with GTM interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
In Stock
HDA36100ABBCSNYP
HDA36100ABBCSNYP
Square D - Molded Case
HDA36100ABBCSNYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 100A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch, 12 VDC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,701.00
Limited Stock
MDN4083LEA0322NMNG2YHKCSX
MDN4083LEA0322NMNG2YHKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG2YHKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
FCS326TE020R
FCS326TE020R
General Electric - Molded Case
FCS326TE020R General Electric Record Plus, type , FC100 frame, 2P in 3P envelope, 1PH, 20A, 600V, 25kA@480V, standard interrupting capacity, Bolt-On, complete with LI - Long-Time and Instantaneous trip functions, lugs not included, fixed Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNENNNLCSX
MDN4083LEA0622NMNENNNLCSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNENNNLCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PJD36025CU73AE1AA
PJD36025CU73AE1AA
Schneider Electric - Molded Case
PJD36025CU73AE1AA, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 250A, 600V, 65kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with 1A/1B auxiliary switch, micrologic interchangeable harmonic 5.0H trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNR2NNKMAX
MDN4083LEA0722NMNR2NNKMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR2NNKMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
S5H400MW
S5H400MW
ABB - Molded Case
S5H400MW, ABB, SACE Isomax, type , 3P, 3PH, 400A, 600V, 65kA@480V, UL listed, Bolt-On, suitable for reverse feed applications, complete with I - Instantaneous protection only and load side lug terminals, MCP, motor circuit protectors, magnetic range 600-4800A, Magnetic Only, molded case circuit breakers
From Get Price
In Stock
TEF134010
TEF134010
General Electric - Molded Case
TEF134010, General Electric, TEF Series, type , 3P, 3PH, 10A, 480V, 14kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with LI - Long-Time and Instantaneous trip functions, lugs not included, Thermal Magnetic, molded case circuit breakers; these breakers are obsolete however we still stock them
From $330.54
In Stock
HGA36150ABBESKYP
HGA36150ABBESKYP
Square D - Molded Case
HGA36150ABBESKYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 150A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch and overcurrent trip switch, 24 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,850.41
Limited Stock
MDN4083LEA0322NMNN4NNNNPX
MDN4083LEA0322NMNN4NNNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN4NNNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
E3V-A16-4P-400A-BO-EO-LI
E3V-A16-4P-400A-BO-EO-LI
ABB - Insulated Case
E3V-A16-4P-400A-BO-EO-LI, ABB, EMax, type , 4P, 3PH, 1600A frame, 400A rating plug, 600V, 125kA@480V, fixed mount/Bolt-On, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price