1. Home / 
  2. square d breaker

SORT BY
Limited Stock
PDF54M1200D4YN
PDF54M1200D4YN
Cutler Hammer - Molded Case
PDF54M1200D4YN, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 1200A, 65kA@480V, Bolt-On, no terminals, complete with PXR20D trip with LSI - Long-Time, Short-Time and Instantaneous trip with ARMS functions with relays, modbus, ZSI & CAM option, Solid State electronic, molded case circuit breakers; globally rated with 100% UL rating
From Get Price
Limited Stock
SHF3G6W8W
SHF3G6W8W
General Electric - Insulated Case
SHF3G6W8W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MP340KMF
MP340KMF
Murray Corporation - Molded Case
MP340KMF, Murray Corporation, MP Series, type , 3P, 3PH, 40A, 240V, 65kA@240V, high interrupting capacity, 40°C, fungus proofing, Plug-In, common trip, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
XT4SQ3100EFF000XXX
XT4SQ3100EFF000XXX
ABB - Molded Case
XT4SQ3100EFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 3-Pole, 100A, 600V, 22kA@600V, Ekip LS/I (Electronic, LS/I protection), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No - 1SDA07211R1 global reference
From Get Price
Limited Stock
MDN4083LEA0122NMNR4NNHCSX
MDN4083LEA0122NMNR4NNHCSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNR4NNHCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PDG32K0125E4NK
PDG32K0125E4NK
Eaton - Molded Case
PDG32K0125E4NK, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 125A, 50kA@480V, Bolt-On, line side lug terminals, complete with PXR20 trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions , Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0422NMNG2NNANPX
MDN4083LEA0422NMNG2NNANPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG2NNANPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, operations counter, & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNXNYNCDCX
MDN4083LEA0522NMNXNYNCDCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNXNYNCDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNJ4ENKCSX
MDN4083LEA0122NMNJ4ENKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJ4ENKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNK4ENNCPX
MDN4083LEA0122NMNK4ENNCPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK4ENNCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNA4YCNDSX
MDN4083LEA0722NMNA4YCNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNA4YCNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNX4YNNMCX
MDN4083LEA0122NMNX4YNNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNX4YNNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
WLL2F312EY
WLL2F312EY
Siemens - Insulated Case
WLL2F312EY, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 1200A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU755 programmer + WLGFM76 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 315A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
5925-00-876-9218
5925-00-876-9218
Eaton - Molded Case
5925-00-876-9218, Eaton, Naval, type , 60 cycles, 3P, 3PH, 50A, 500Vac/250Vdc, 15kA@500V, 50°C, Plug-In, LO trip setting: 600-700; HI trip setting: 250-350, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers for naval shipboard use
From Get Price
Limited Stock
KXT4EWFPHR-3
KXT4EWFPHR-3
ABB - Part And Accessory
KXT4EWFPHR-3, ABB, SACE Tmax XT, fixed part of withdrawable circuit breaker, with horizontal/vertical rear terminals, suitable for use with 3P type XT4 circuit breakers; 1SDA068205R1 global reference
From Get Price
Limited Stock
MDN4083LEA0722NMNGNNNYCCX
MDN4083LEA0722NMNGNNNYCCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNGNNNYCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSD1G3Q9K
SSD1G3Q9K
General Electric - Insulated Case
SSD1G3Q9K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
HNB2800V
HNB2800V
Cutler Hammer - Molded Case
HNB2800V, Westinghouse, Cutler Hammer, MARK 75, type , 2P, 1PH, 800A, 600V, 35kA@480V, high interrupting capacity, Bolt-On, 50°C, complete with interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic molded case circuit breakers, these breakers are obsolete; however we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNXNENHMAX
MDN4083LEA0422NMNXNENHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNXNENHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNF2ENLMCX
MDN4083LEA0822NMNF2ENLMCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF2ENLMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNH4NNACCX
MDN4083LEA0122NMNH4NNACCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNH4NNACCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PDD23M0110TFFL
PDD23M0110TFFL
Eaton - Molded Case
PDD23M0110TFFL, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 240V, 110A, 100kA@240V, Bolt-On, load terminals only, complete with LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; UL, CSA certifications
From Get Price
Limited Stock
MDN4083LEA0822NMNKNYNCDAX
MDN4083LEA0822NMNKNYNCDAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNKNYNCDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHF3G624U
SHF3G624U
General Electric - Insulated Case
SHF3G624U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price