Limited Stock
TJ43PD2
TJ43PD2
General Electric - Part And Accessory
TJ43PD2, General Electric, Tri-Break, part and accessory, Connection Devices, plug-in mounting base assembly with hardware, 3-pole, 400A, LSL stab configuration, 2 required per breaker, suitable for use with Tri-Break, type TJJ,TJK,THJK,TB4,TJS molded case circuit breakers
From Get Price
Limited Stock
KS4125TAG
KS4125TAG
Cutler Hammer - Trip Units And Programmers
KS4125TAG, Cutler Hammer, Series C Seltronic trip units and programmers with LSG - Long-Time, Short-Time and Ground Fault trip functions, rated for 125A, 4P with neutral protection, suitable for Series C- KD,HKD,KDC,KW,HKW,KWC molded case circuit breaker frames
From Get Price
Limited Stock
665A321G01
665A321G01
Eaton - Primary Current Part
665A321G01, Westinghouse, Cutler Hammer, Eaton, DS Series, Moving Main Contact, Included in lower stud assembly, qty 3 needed per breaker, for use with Manual/Electric operator, suitable for DS-206H, DS-206S, DS-416, DSL-416, DSII-508, DSII-516 air breakers
From Get Price
In Stock
IQESF480
IQESF480
Cutler Hammer - Part And Accessory
IQESF480, Cutler Hammer, IQ Energy Sentinel, microprocessor-based submeter designed to monitor power, energy and monitors watts, watthour and watt demand; built-in CT, breaker, panel or DIN-rail mounted; 480V, suitable for mounting on 150A max Series C F-Frame breakers
From $1,191.40
Limited Stock
CJT2B400
CJT2B400
Siemens - Trip Units And Programmers
CJT2B400, Siemens, VL Series, type CJT, interchangeable model 525 trip unit with LI, LI - Long-Time and Instantaneous trip functions, rated for 400A, suitable for JG 400A- NJG,HJG,LJG molded case circuit breaker frame types, Thermal Magnetic trip units & circuit breakers
From Get Price
Limited Stock
MS6B-800-2-N12-CB
MS6B-800-2-N12-CB
Saf Drives - Soft Starter
MS6B-800-2-N12-CB, Saf Drives, Opal Pro, soft starter, cominbation unit with HP rated bypass contactor, Series, 3PH 50/60Hz, 800FLA, 600HP@480V, keypad and LCD display, soft stop, enclosed in NEMA type 12 disconnect with circuit breaker installed
From Get Price
Limited Stock
E2J3250TMC
E2J3250TMC
Cutler Hammer - Trip Units And Programmers
E2J3250TMC, Cutler Hammer, Series C, type , 3P, interchangeable trip, I - Instantaneous trip function, rated for 250A, magnetic trip range 450-900A, suitable for 250A- E2J,E2JM mining service Magnetic Only molded case circuit breaker frame types, Magnetic Only trip units & circuit breakers
From Get Price
Limited Stock
ELLBN4600W
ELLBN4600W
Cutler Hammer - Part And Accessory
ELLBN4600W, Cutler Hammer, Series G, type frame, part and accessory, Communication Modules, ground fault (earth leakage) circuit breaker modules, bottom mounted, UL rated, 600A, 4 pole, 120-480Vac, 50/60Hz, suitable for use with Series G LG Frame molded case circuit breakers
From Get Price
In Stock
THQL2135ST1
THQL2135ST1
General Electric - Molded Case
THQL2135ST1, General Electric, type , 2P, 1PH, 35A, 120/240V, 10kA@240V, UL listed, Plug-In, complete with internal common trip with factory installed shunt, LI - Long-Time and Instantaneous trip functions and load side lug terminal, Thermal Magnetic, molded case circuit breaker
From $62.15
Limited Stock
KS4250TG
KS4250TG
Cutler Hammer - Trip Units And Programmers
KS4250TG, Cutler Hammer, Series C Seltronic trip units and programmers with LSG - Long-Time, Short-Time and Ground Fault trip functions, rated for 250A, 4P with neutral protection, suitable for Series C- KD,HKD,KDC,KW,HKW,KWC molded case circuit breaker frames
From Get Price
Limited Stock
FEN46AA160JJF
FEN46AA160JJF
General Electric - Trip Units And Programmers
FEN46AA160JJF, General Electric, Record Plus, Selective electronic interchangeable trip (SMR1) without rating plug, LS - Long-Time and Short-Time trip functions, rated for 160A, 690V, 4P, suitable for FE160 frame- FEN molded case circuit breaker frame types, Solid State trip units & circuit breakers
From Get Price
Limited Stock
PD6D20A120
PD6D20A120
Cutler Hammer - Rating Plug
PD6D20A120, Cutler Hammer, Magnum DS, type , retrofit rating plug, rated for 1200A, 2000A sensor rating, 50/60Hz, style number 2613D10G25, suitable for use with DS molded case circuit breaker frames, for use with Digitrip RMS thermal magnetic trip units & circuit breakers
From Get Price
Limited Stock
8739SCW18V06
8739SCW18V06
Square D - Motor Starter
8739SCW18V06, Square D, Class 8739, type , full voltage reversing motor starter with HLL 20A thermal magnetic circuit breaker, 3P, 3PH, 7.5HP @ 600V, 600V with 480V 60Hz/440V 50Hz coil, NEMA size 1, includes NEMA 4X watertight and dust-tight polyester enclosure
From Get Price
Limited Stock
AKRT-NB-50H-EO-DO
AKRT-NB-50H-EO-DO
General Electric - Air
AKRT-NB-50H-EO-DO, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAV}@480VAC, Standard Electric Operator, Non-Automatic, Control Voltage and Wiring to be determined before ordering
From Get Price
Limited Stock
ENT4004BL3H2
ENT4004BL3H2
General Electric - Panel Board
ENT4004BL3H2, General Electric, EntellEon, type , low-voltage panel board interior, UL listed, 3-phase, 3-wire, main 400A rated, 600VAC, 40X, bolted lug pad, Copper bus material, Main Breaker style; to be used with SK, SG, SF, SE main circuit breakers
From Get Price
Limited Stock
PD6D40A320
PD6D40A320
Cutler Hammer - Rating Plug
PD6D40A320, Cutler Hammer, Magnum DS, type , retrofit rating plug, rated for 3200A, 4000A sensor rating, 50/60Hz, style number 2613D10G37, suitable for use with DS molded case circuit breaker frames, for use with Digitrip RMS thermal magnetic trip units & circuit breakers
From Get Price
Limited Stock
SNT1RA18
SNT1RA18
Cutler Hammer - Shunt Trip
SNT1RA18, Cutler Hammer, Series C, factory mounted shunt trip, 600 - 600V, right or neutral pole mounted, pigtail style leads, suitable for use with Series C FDB,FD,HFD,HFDDC,FDC,FG,E2F,E2FM and F-frame HMCP molded case circuit breaker frames
From Get Price
Limited Stock
SEH3C080
SEH3C080
Challenger - Molded Case
SEH3C080, Sylvania, Challenger, SEH Series, type , 3P, 3PH, 80A, 480V, 14kA@480V, standard interrupting capacity, 40ºC, Bolt-On, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers; this breaker is now obsolete; however, we still stock them
From Get Price
Limited Stock
SNT1LC08
SNT1LC08
Cutler Hammer - Shunt Trip
SNT1LC08, Cutler Hammer, Series C, factory mounted shunt trip, 127 - 127V, left pole mounted, opposite side connected, pigtail style leads, suitable for use with Series C FDB,FD,HFD,HFDDC,FDC,FG,E2F,E2FM and F-frame HMCP molded case circuit breaker frames
From Get Price
Limited Stock
8739SEW13V08
8739SEW13V08
Square D - Motor Starter
8739SEW13V08, Square D, Class 8739, type , full voltage reversing motor starter with HLL 100A thermal magnetic circuit breaker, 3P, 3PH, 40HP @ 480V, 50HP @ 600V, 600V with 208V 60Hz coil, NEMA size 3, includes NEMA 4X watertight and dust-tight polyester enclosure
From Get Price
Limited Stock
NB2300PT
NB2300PT
Westinghouse - Trip Units And Programmers
NB2300PT, Westinghouse, TRI-PAC, interchangeable trip, LI - Long-Time and Instantaneous trip functions, rated for 300A, 600V, 2P, suitable for 800A- NB molded case circuit breaker frame, Thermal Magnetic trip units & circuit breakers; these trips are obsolete, however we still stock them
From Get Price
Limited Stock
8739SCA8V08
8739SCA8V08
Square D - Motor Starter
8739SCA8V08, Square D, Class 8739, type , full voltage reversing motor starter with HLL 20A thermal magnetic circuit breaker, 3P, 3PH, 7.5HP @ 600V, 600V with 208V 60Hz coil, NEMA size 1, includes NEMA 12/3R dust-tight industrial use enclosure without external reset
From Get Price
Limited Stock
431703
431703
General Electric - Trip Units And Programmers
431703, General Electric, Record Plus, Selective electronic interchangeable trip (SMR1) without rating plug, LS - Long-Time and Short-Time trip functions, rated for 160A, 690V, 3P, suitable for FE160 frame- FEN molded case circuit breaker frame types, Solid State trip units & circuit breakers
From Get Price
Limited Stock
ENT4012BL3H2
ENT4012BL3H2
General Electric - Panel Board
ENT4012BL3H2, General Electric, EntellEon, type , low-voltage panel board interior, UL listed, 3-phase, 3-wire, main 1200A rated, 600VAC, 40X, bolted lug pad, Copper bus material, Main Breaker style; to be used with SK, SG, SF, SE main circuit breakers