QNBAL2025
Westinghouse - Molded Case
QNBAL2025, Westinghouse, Quicklag, type , 2P, 1PH, 25A, 120/240V, 10kA@240V, standard interrupting capacity, 40ºC, Bolt-On, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers; this breaker is obsolete and has been replaced by BAB breakers
From Get Price

SE3C060
Challenger - Molded Case
SE3C060, Sylvania, Challenger, SE Series, type SE, 3P, 3PH, 60A, 240V, 14kA@240V, standard interrupting capacity, 40ºC, Bolt-On, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers; this breaker is now obsolete; however, we still stock them
From Get Price

MPD2175RHB
Murray Corporation - Molded Case
MPD2175RHB, Murray Corporation, MD Series, type , main circuit breaker without lugs, 2P, 1PH, 175A, 120/240V, 22kA@240V, high interrupting capacity, Plug-In, reverse handle, complete with LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers
From Get Price

FEL36AA025JBF
General Electric - Trip Units And Programmers
FEL36AA025JBF, General Electric, Record Plus, Selective electronic interchangeable trip (SMR1) without rating plug, LS - Long-Time and Short-Time trip functions, rated for 25A, 690V, 3P, suitable for FE160 frame- FEL molded case circuit breaker frame types, Solid State trip units & circuit breakers
From Get Price

THHQL1130GFT
General Electric - Molded Case
THHQL1130GFT, General Electric, type , 1P, 1PH, 30A, 120V, 22kA@120V, UL listed, Plug-In, complete with ground fault circuit interrupters with self-test, LI - Long-Time and Instantaneous trip functions and load side lug terminal, Thermal Magnetic, molded case circuit breaker
From Get Price

GL100M5-SF
General Electric - Trip Units And Programmers
GL100M5-SF, General Electric, M-PACT Plus, MPRO-27 programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, rated for 400-4000A, suitable for frame size 1 MS,MN,MH air circuit breaker frame types, Solid State programmers & circuit breakers
From Get Price

BW2125HP
Cutler Hammer - Molded Case
BW2125HP, Cutler Hammer, BW Series, type , 2P, 1PH, 125A, 240V, 10kA@240V, high interrupting capacity, 40ºC, Bolt-On, with hazard-proof tabs, suitable for use as main breaker, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers
From Get Price

MS6B-500-2-N12-CB
Saf Drives - Soft Starter
MS6B-500-2-N12-CB, Saf Drives, Opal Pro, soft starter, cominbation unit with HP rated bypass contactor, Series, 3PH 50/60Hz, 500FLA, 400HP@480V, keypad and LCD display, soft stop, enclosed in NEMA type 12 disconnect with circuit breaker installed
From Get Price

5-HK-250-1200A
ITE - Air
5-HK-250-1200A, ITE, HK Series, , 3PH, 3P, 5000 VAC, 1200 Frame, Electrically Operated, Draw-Out, Medium Voltage air circuit breaker, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, and Additional Accessories to be determined before ordering.
From Get Price

5-HK-150-1200A
ITE - Air
5-HK-150-1200A, ITE, HK Series, , 3PH, 3P, 5000 VAC, 1200 Frame, Electrically Operated, Draw-Out, Medium Voltage air circuit breaker, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, and Additional Accessories to be determined before ordering.
From Get Price

GL200M3-SR
General Electric - Trip Units And Programmers
GL200M3-SR, General Electric, M-PACT Plus, MPRO-27 programmer, field installable, LSI - Long-Time, Short-Time and Instantaneous trip functions, rated for 400-4000A, suitable for frame size 2 MS,MN,MH air circuit breaker frame types, Solid State programmers & circuit breakers
From Get Price

CNT3B800
Siemens - Trip Units And Programmers
CNT3B800, Siemens, VL Series, type CNT, interchangeable model 525 trip unit with LI, LI - Long-Time and Instantaneous trip functions, rated for 800A, suitable for NG 1200A- NNG,HNG,LNG molded case circuit breaker frame types, Thermal Magnetic trip units & circuit breakers
From Get Price

CMT3V800
Siemens - Trip Units And Programmers
CMT3V800, Siemens, VL Series, type , non-interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, rated for 800A, suitable for MG 800A- NMG,HMG,LMG molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price

BE-04SB250
BRAH Electric - Rating Plug
BE-04SB250, BRAH Electric, SB Series, type , substitute fixed rating plug element, rated for 250A, suitable for use with 400A - SBA, SBH, SBS insulated case circuit breaker frame types, for use with SB-EC, TL solid state electronic trip units & circuit breakers
From Get Price

TK38600TMD4
General Electric - Trip Units And Programmers
TK38600TMD4, General Electric, TK Series, K Frame, type , 3P, interchangeable trip, LI - Long-Time and Instantaneous trip functions, rated for 600A, magnetic trip range 1250-3000A, suitable for TK molded case circuit breaker frame types, Thermal Magnetic trip units & circuit breakers
From Get Price

QO12030M150RB
Square D - Load Center
QO12030M150RB, Square D, QO Series, type , load center, 1-phase, 3-wire, 150A, 120/240V, Main Breaker, convertible main, 20 spaces allowing 30 single-pole circuits, NEMA 3R rainproof enclosure, Copper bus, to be used with type QO plug-on circuit breakers
From Get Price

151D065G02
Westinghouse - Primary Current Part
151D065G02, Eaton, Westinghouse, Cutler Hammer, DS Series, Single Pole Unit, Complete Assembly, qty 3 needed per breaker, for use with Manual/Electric operator, suitable for DS-206E, DS-416H, DS-416S, DS-420, DSII-608, DSII-616, DSII-620 air circuit breakers
From Get Price

CNT3N100
Siemens - Trip Units And Programmers
CNT3N100, Siemens, VL Series, type CNT, interchangeable model 545 trip unit with LI, LI - Long-Time and Instantaneous trip functions, rated for 1000A, suitable for NG 1200A- NNG,HNG,LNG molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price

THQB31WY25
General Electric - Molded Case
THQB31WY25, General Electric, type , 3P, 3PH, 25A, 240V, 10kA@120V, 40°C, UL listed, Bolt-On, with switching neutral two Thermal Magnetic pole; single nonautomatic pole, LI - Long-Time and Instantaneous trip functions and load side lug terminals, molded case circuit breaker
From Get Price

PD6D24A200
Cutler Hammer - Rating Plug
PD6D24A200, Cutler Hammer, Magnum DS, type , retrofit rating plug, rated for 2000A, 2400A sensor rating, 50/60Hz, style number 2613D10G29, suitable for use with DS molded case circuit breaker frames, for use with Digitrip RMS thermal magnetic trip units & circuit breakers
From Get Price

CC2125SR12
Cutler Hammer - Molded Case
CC2125SR12, Cutler Hammer, CC Series, type , 2P, 1PH, 125A, 240V, 10kA@240V, with line & load lug terminals, complete with 12VDC shunt trip, standard interrupting capacity, 40°C, Feed-Thru, suitable for use as main breaker, Thermal Magnetic molded case circuit breakers
From Get Price

CMT4N800
Siemens - Trip Units And Programmers
CMT4N800, Siemens, VL Series, type CMT, interchangeable model 545 trip unit with LI, LI - Long-Time and Instantaneous trip functions, rated for 800A, suitable for MG 800A- NMG,HMG,LMG molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price

CNT4N100
Siemens - Trip Units And Programmers
CNT4N100, Siemens, VL Series, type CNT, interchangeable model 545 trip unit with LI, LI - Long-Time and Instantaneous trip functions, rated for 1000A, suitable for NG 1200A- NNG,HNG,LNG molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price

JT4150T
Cutler Hammer - Trip Units And Programmers
JT4150T, Cutler Hammer, Series C, type , trip units and programmers, interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 150A, suitable for HJDDC,JD,HJD,JDC molded case circuit breaker frame types, Thermal Magnetic trip units & circuit breakers