1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0322NMNR4YNKDCX
MDN4083LEA0322NMNR4YNKDCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNR4YNKDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNA4NNCNAX
MDN4083LEA0622NMNA4NNCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNA4NNCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSD1G2A7B
SSD1G2A7B
General Electric - Insulated Case
SSD1G2A7B, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering & RELT features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD4G659M
SHD4G659M
General Electric - Insulated Case
SHD4G659M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communcation & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNE2ENRDSX
MDN4083LEA0522NMNE2ENRDSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE2ENRDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
WLL2F325RR
WLL2F325RR
Siemens - Insulated Case
WLL2F325RR, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 2500A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU755 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 1250A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SHB2G5Q8T
SHB2G5Q8T
General Electric - Insulated Case
SHB2G5Q8T, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
B330LSIGDZ2P
B330LSIGDZ2P
General Electric - Trip Units And Programmers
B330LSIGDZ2P, General Electric, MicroVersaTrip PM, type , trip units and programmers, 3000A current sensor rating, Solid State electronic, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, ground fault defeatable trip functions, short-time selective interlock, protective relays & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price
Limited Stock
B1NQ1D32T
B1NQ1D32T
Noark Electric - Molded Case
B1NQ1D32T, Noark Electric, UL 489, type , 1PH, 1P, 120/240V, 32A, 10kA@240V, Bolt-On quick connect terminals load side, Thermal Magnetic, D trip curve, din rail mounted molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNX4NNKNPX
MDN4083LEA0722NMNX4NNKNPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX4NNKNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SEHF36600LSGET6
SEHF36600LSGET6
Schneider Electric - Insulated Case
SEHF36600LSGET6, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 600A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & 48VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MPA32F32W3210
MPA32F32W3210
General Electric - Insulated Case
MPA32F32W3210, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50H trip unit, 110/130V dc/ac motor operator, 48V dc closing coil, 24/30V dc shunt trip, 3P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SHD5G8Y6W
SHD5G8Y6W
General Electric - Insulated Case
SHD5G8Y6W, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SED36400LSGD8
SED36400LSGD8
Square D - Insulated Case
SED36400LSGD8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
1375D66G14
1375D66G14
Cutler Hammer - Electrical Operator
1375D66G14, Cutler Hammer, SPB Series, type , electrical operator, electrical operator kit, Vdc, behind-the-door and fixed, suitable for 4000/5000A SPB50,SPB65,SPB100 insulated case circuit breakers
From Get Price
Limited Stock
XT7LQ480CCFF000XXX
XT7LQ480CCFF000XXX
ABB - Molded Case
XT7LQ480CCFF000XXX, ABB, SACE Tmax XT, type , UL 100% rated, 3PH, 4P, 600V, 800A, 100kA@480V, , front terminals, complete with Ekip trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Ekip DIP LIG, molded case circuit breakers; 1SDA103262R1 + 1SDA107724R1 global reference
From Get Price
Limited Stock
SED361200ES8D8
SED361200ES8D8
Schneider Electric - Insulated Case
SED361200ES8D8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNGNEMNMPX
MDN4083LEA0422NMNGNEMNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNGNEMNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SED36600LSGES9E8
SED36600LSGES9E8
Square D - Insulated Case
SED36600LSGES9E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 600A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHF361000LIES5E4
SEHF361000LIES5E4
Square D - Insulated Case
SEHF361000LIES5E4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MPA41F20W4250
MPA41F20W4250
General Electric - Insulated Case
MPA41F20W4250, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 220/250V dc/ac motor operator, 48V dc closing coil and 380/400V ac shunt trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
FDC4100VL
FDC4100VL
Westinghouse - Molded Case
FDC4100VL, Cutler Hammer, Eaton, Westinghouse, Series C, type , 4P, 3PH, 100A, 600V, 100kA@480V, current limiting, 50°C, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
SEF36600ES2A4
SEF36600ES2A4
Square D - Insulated Case
SEF36600ES2A4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNE4NNKCCX
MDN4083LEA0522NMNE4NNKCCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE4NNKCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price