1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0522NMNR2YNNNCX
MDN4083LEA0522NMNR2YNNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR2YNNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
In Stock
HDA260901AFBKSKYP
HDA260901AFBKSKYP
Square D - Molded Case
HDA260901AFBKSKYP, Square D, PowerPact, type , 2P, A & B phase connection, 1PH, 90A, 600V, 18kA@480V, UL listed, standard interrupting capacity, I-Line Style Plug-In, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, complete with 2A/2B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 24 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,514.41
Limited Stock
MDN4083LEA0122NMNR2YNYMAX
MDN4083LEA0122NMNR2YNYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNR2YNYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNN4ENLNWX
MDN4083LEA0722NMNN4ENLNWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4ENLNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNCNNNHCAX
MDN4083LEA0322NMNCNNNHCAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNCNNNHCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNJNEMNMCX
MDN4083LEA0822NMNJNEMNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJNEMNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
In Stock
HGA36100U44XAFBHUH
HGA36100U44XAFBHUH
Square D - Molded Case
HGA36100U44XAFBHUH, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 100A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, micrologic ammeter 6.2A non-interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch low-level, 380/480 VAC under voltage release (UVR), molded case circuit breakers
From $3,249.75
In Stock
HLA36150U31XAFBCSPYP
HLA36150U31XAFBCSPYP
Square D - Molded Case
HLA36150U31XAFBCSPYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 150A, 600V, 100kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2 non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch, 48 VDC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $3,974.91
Limited Stock
MDN4083LEA0722NMNFNYNADAX
MDN4083LEA0722NMNFNYNADAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNFNYNADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
In Stock
HGL36020AEBKUPYP
HGL36020AEBKUPYP
Square D - Molded Case
HGL36020AEBKUPYP, Square D, PowerPact, type , 3P, 3PH, 20A, 600V, 35kA@480V, high interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 48 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,539.93
Limited Stock
MDN4083LEA0422NMNGNNNLNSX
MDN4083LEA0422NMNGNNNLNSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNGNNNLNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & Castell key interlock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
In Stock
HJA36150AEBKSVYP
HJA36150AEBKSVYP
Square D - Molded Case
HJA36150AEBKSVYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 150A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 60 VDC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,539.32
Limited Stock
MDN4083LEA0422NMNK4EHNNAX
MDN4083LEA0422NMNK4EHNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK4EHNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
In Stock
HDA36060U44XAFBKSP
HDA36060U44XAFBKSP
Square D - Molded Case
HDA36060U44XAFBKSP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 60A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, micrologic ammeter 6.2A non-interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 48 VDC shunt trip, molded case circuit breakers
From $2,325.75
Limited Stock
MDN4083LEA0322NMNK4ENAMWX
MDN4083LEA0322NMNK4ENAMWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK4ENAMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNH2ENCNCX
MDN4083LEA0822NMNH2ENCNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH2ENCNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
In Stock
HJA36060U43XAEBKUS
HJA36060U43XAEBKUS
Square D - Molded Case
HJA36060U43XAEBKUS, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 60A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, micrologic ammeter 5.2A non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 250 VDC under voltage release (UVR), molded case circuit breakers
From $3,291.75
In Stock
HDA36150U31XAEBEUN
HDA36150U31XAEBEUN
Square D - Molded Case
HDA36150U31XAEBEUN, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 150A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2 non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, 12 VDC under voltage release (UVR), molded case circuit breakers
From $2,980.83
Limited Stock
MDN4083LEA0622NMNG4YNYNAX
MDN4083LEA0622NMNG4YNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNG4YNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch, Kirk key interlock & operations counter, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNE2YNNNCX
MDN4083LEA0222NMNE2YNNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE2YNNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNH2YNHNAX
MDN4083LEA0322NMNH2YNHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNH2YNHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNJNYNRNWX
MDN4083LEA0822NMNJNYNRNWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJNYNRNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
In Stock
HGA36060U33XBHSLYP
HGA36060U33XBHSLYP
Square D - Molded Case
HGA36060U33XBHSLYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 60A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2S non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, complete with alarm switch low-level, 48 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,306.85
Limited Stock
MDN4083LEA0422NMNKNYNCMWX
MDN4083LEA0422NMNKNYNCMWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNKNYNCMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price