PLF34080CU73AE1AB
Schneider Electric - Molded Case
PLF34080CU73AE1AB, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 800A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, 100% rated, complete with 2A/2B auxiliary switch, micrologic interchangeable harmonic 5.0H trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price

HRA36100U31XABBHSR
Square D - Molded Case
HRA36100U31XABBHSR, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 100A, 600V, 200kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2 non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, complete with 2A/2B aux switch, alarm switch low-level, 125 VDC shunt trip, molded case circuit breakers
From $4,039.73

HJL36030AABKSR
Square D - Molded Case
HJL36030AABKSR, Square D, PowerPact, type , 3P, 3PH, 30A, 600V, 65kA@480V, UL listed, current limiting, Feed-Thru, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 1A/1B aux switch, alarm switch and overcurrent trip switch, low-level, 125 VDC shunt trip, molded case circuit breakers
From $1,581.09

SEHF361400LIT3
Square D - Insulated Case
SEHF361400LIT3, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 48VDC shunt trip & 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEF361000LIES8E8
Schneider Electric - Insulated Case
SEF361000LIES8E8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1000A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0122NMNK4NNYDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK4NNYDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

SEF36600LSIES6D4
Square D - Insulated Case
SEF36600LSIES6D4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0522NMNK2NNNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK2NNNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SEHF36250ES5E4
Schneider Electric - Insulated Case
SEHF36250ES5E4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 250A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

HGL26070AABKUOYP
Square D - Molded Case
HGL26070AABKUOYP, Square D, PowerPact, type , 2P, 1PH, 70A, 600V, 35kA@480V, high interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 1A/1B aux switch, alarm switch and overcurrent trip switch, low-level, 24 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,821.75

MDN4083LEA0222NMNE2ENYDCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE2ENYDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

SEHD361400LSES1F4
Schneider Electric - Insulated Case
SEHD361400LSES1F4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

TR30S3000
General Electric - Rating Plug
TR30S3000, General Electric, Power Break I, type , rating plug element, rated for 3000A, 3000A sensor rating, suitable for use with 3000A - TP,TC,THP,THC insulated case circuit breaker frame types, for use with MicroVersaTrip RMS-9 trip units & circuit breakers
From $10,803.78

MDN4083LEA0722NMNX4EHNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX4EHNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

SED361000LIGS3
Square D - Insulated Case
SED361000LIGS3, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 48VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0822NMNG4ENADSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG4ENADSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

HGA36045ABBKYP
Square D - Molded Case
HGA36045ABBKYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 45A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch and overcurrent trip switch, low-level, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,427.37

PKD36120CU74AE1BD
Schneider Electric - Molded Case
PKD36120CU74AE1BD, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1200A, 600V, 50kA@480V, UL listed, high interrupting capacity, Draw-Out, 100% rated, complete with 1A/1B overcurrent trip switch, micrologic interchangeable harmonic 6.0H trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers
From Get Price

AKF-2D-4000A-EO-DO
General Electric - Air
AKF-2D-4000A-EO-DO, General Electric, AKF Series, , 2PH, 2P, 480 VDC, 4000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-4000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

SHF1G359I
General Electric - Insulated Case
SHF1G359I, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 450A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

WLS2D312NU
Siemens - Insulated Case
WLS2D312NU, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 1200A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU755 programmer + WLGFM76 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 800A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

MPA32F40N2320
General Electric - Insulated Case
MPA32F40N2320, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-27 trip unit, 48Vdc motor operator, 110/130V dc/ac closing coil and 48V dc shunt trip, 3P, 3PH, 4000A, 690V, 50kA@415V, fixed/Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price

SEHD363000LSES8E8
Square D - Insulated Case
SEHD363000LSES8E8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0522NMNRNYNCMWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNRNYNCMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired