MPA31F0802134
MPA31F0802134
General Electric - Insulated Case
MPA31F0802134, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 48V dc motor operator, 24/30V dc closing coil, 110/130V dc/ac shunt trip and 380/440V ac undervoltage trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
K440LSIR
K440LSIR
General Electric - Trip Units And Programmers
K440LSIR, General Electric, MicroVersaTrip Plus, replacement trip units and programmers, 4000A current sensor rating, Solid State electronic, LSI - Long-Time, Short-Time and Instantaneous trip functions, suitable for use with 4000A frame WavePro WPS,WPH,WPF,WPX low voltage power circuit breakers
From Get Price
Limited Stock
WLH1F320TY
WLH1F320TY
Siemens - Insulated Case
WLH1F320TY, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 2000A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU755 programmer + WLGFM76 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 1600A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
UVT3101UA
UVT3101UA
Noark Electric - Under Voltage Release
UVT3101UA, Noark Electric, Ex9 Series, under voltage release with 1NC aux contact, 240Vac, suitable for use with all Noark UL 1077 rated Ex9 Series circuit breakers
From Get Price
Limited Stock
REF3A050
REF3A050
Miami Breaker - Molded Case
REF3A050, Miami Breaker, REF Series, type , 3P, 3PH, 50A, 600V, 14kA@480V, standard interrupting capacity, Bolt-On, complete with I - Instantaneous protection only and load side lug terminals, standard magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNGNENKMPX
MDN4083LEA0822NMNGNENKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNGNENKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNG2YNNMPX
MDN4083LEA0622NMNG2YNNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNG2YNNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNF4YNCDWX
MDN4083LEA0822NMNF4YNCDWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF4YNCDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
S201U-Z25
S201U-Z25
ABB - Molded Case
S201U-Z25, ABB, S 200 U Series, type , 1P, 1PH, 25A, 240Vac, 10kA@240Vac, standard interrupting capacity, current limiting, DIN rail mounted, Feed-Thru, suitable for reverse feed, UL/CSA/IEC approval, branch circuit protection, Z trip characteristic, Thermal Magnetic trip functions, Thermal Magnetic, miniature molded case circuit breakers and supplemental protectors
From Get Price
Limited Stock
247039G
247039G
General Electric - Molded Case
247039G, General Electric, MB Series, type , MB61C20, C tripping, 1P, 1PH, 20A, 415V, 6kA@415V, Bolt-On, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case miniature circuit breakers
From Get Price
Limited Stock
WLL1F320MT
WLL1F320MT
Siemens - Insulated Case
WLL1F320MT, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 2000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU755 programmer + WLGFA76 ground fault module, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 700A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
TF4P1060
TF4P1060
General Electric - Molded Case
TF4P1060 General Electric TF Series, type , 4P, 1 protected pole and 3 nonautomatic poles, 3PH, 60A, 600V, 22kA@600V, standard interrupting capacity, Bolt-On, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
PDG34P0400E4CJ
PDG34P0400E4CJ
Eaton - Molded Case
PDG34P0400E4CJ, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 400A, 100kA@480V, Feed-Thru, line & load side lug terminals, complete with PXR20 trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions and CAM link & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0422NMNG4ENHMAX
MDN4083LEA0422NMNG4ENHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG4ENHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNF4YNLDPX
MDN4083LEA0822NMNF4YNLDPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF4YNLDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
WLL2F330UK
WLL2F330UK
Siemens - Insulated Case
WLL2F330UK, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 3000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU748 programmer + WLLCD48 LCD display, LS - Long-Time and Short-Time trip functions and 2000A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SSD1G3L4L
SSD1G3L4L
General Electric - Insulated Case
SSD1G3L4L, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 700A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
G1X00L3XXXRXXX
G1X00L3XXXRXXX
General Electric - Trip Units And Programmers
G1X00L3XXXRXXX, General Electric, EntelliGuard universal spare replacement trip units and programmers, 3P, 600/635V, LSI - Long-Time, Short-Time and Instantaneous trip functions, suitable for use with ANSI rated ENTELLIGUARD G,PBI,PBII,AK,AKR,WAVEPRO,MPACT LVPCB's and ICCB's
From Get Price
Limited Stock
TPSS6616FCD
TPSS6616FCD
General Electric - Insulated Case
TPSS6616FCD, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 1600A, Front Connected, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNHNNNYNAX
MDN4083LEA0522NMNHNNNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNHNNNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNJNYNKNAX
MDN4083LEA0522NMNJNYNKNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJNYNKNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
1221C21G14
1221C21G14
Cutler Hammer - Shunt Trip
1221C21G14, Cutler Hammer, SPB Series, type , shunt trip assembly kit for behind-the-door and fixed breakers, 48Vac, 50/60Hz, suitable for use with 4000/5000A SPB50,SPB65,SPB100 circuit breaker frames
From Get Price
Limited Stock
LPY3G120
LPY3G120
Siemens - Molded Case
LPY3G120, Siemens, VL Series, type , 3P, 3PH, 1200A, 600V, 100kA@480V, very high interrupting capacity, Bolt-On, 100% rated, complete with non-interchangeable trip with LCD display, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNCNYCNNCX
MDN4083LEA0722NMNCNYCNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNCNYCNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price